HP (Hewlett-Packard)メーカー8753ETの使用説明書/サービス説明書
ページ先へ移動 of 28
specifications 8753ET /ES Network Analyzers HP 8753ET and 8753ES Network Analyzers 30 kHz to 3 or 6 GHz This document describes the performance and features of the following products: HP 8753ES S-para.
2 T able of contents Definitions and test conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 System performance summaries . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Specifications and characteristics . . . . . . . . . .
3 Definitions and test conditions Specifications describe the instrument's warranted performance after a half-hour warm-up and over the temperature range of 25 ˚C ± 5 ˚C, unless otherwise stated. Specifications for frequencies above 3 GHz do not apply to instruments with Option 075 (75-ohm impedance).
4 System performance summaries HP 8753ES (50-ohm systems) 7-mm test ports Configuration Network analyzer HP 8753ES Standard and Option 006 Calibration kit HP 85031B T est-port cables HP 11857D System .
5 System performance summaries HP 8753ES (50-ohm systems) T ype-N test ports Configuration Network analyzer HP 8753ES Standard and Option 006 Calibration kit HP 85032B T est-port cables HP 11857D Syst.
6 System performance summaries HP 8753ES (50-ohm systems) 3.5-mm test ports Configuration Network analyzer HP 8753ES Standard and Option 006 Calibration kit HP 85033D T est-port cables HP 11857D Syste.
7 System performance summaries HP 8753ES (75-ohm systems) T ype-N test ports Configuration Network analyzer HP 8753ES Option 075 Calibration kit HP 85036B T est-port cables HP 11857B System dynamic ra.
8 System performance summaries HP 8753ES (75-ohm systems) T ype-F test ports Configuration Network analyzer HP 8753E Option 075 Calibration kit HP 85039B T est-port cables HP 11857B System dynamic ran.
9 System performance summaries HP 8753ET (50-ohm systems) T ype-N test ports Configuration Network analyzer HP 8753ET Standard, Option 006 or Option 004 Calibration kit HP 85032B T est port cable HP p.
10 HP 8753ES specifications T est-port output characteristics 7 Frequency characteristics Range 30 kHz to 3 GHz Option 006 30 kHz to 6 GHz Resolution 1 Hz Stability 9 ±7.5 ppm (0˚ to 55 ˚C) ±3 ppm/year Accuracy ±10 ppm at 25 ˚C ± 5 ˚C Option 1D5 ±0.
11 T est port input characteristics (continued) External source mode 1 (CW time sweep only) Frequency range 300 kHz to 6 GHz R-channel input requirements (typical) Power level 0 to -25 dBm Spectral purity Maximum <-30 dBc spurious input Residual FM <20 kHz T ypical settling 500 ms (automatic) time 50 ms (manual) Frequency readout 0.
12 HP 8753ES Option 011 specifications T est port output characteristics Frequency characteristics Range 300 kHz to 3 GHz Option 006 30 kHz to 6 GHz Resolution 1 Hz Stability typically ±7.5 ppm 0˚ to 55 ˚C typically ±3 ppm/year Option 1D5 typically ± 0.
13 HP 8753ES Option 011 specifications T est port input characteristics (continued) Frequency offset mode 3 Frequency range 300 kHz to 3 GHz Option 006 300 kHz to 6 GHz R-channel input requirements Po.
14 HP 8753ET specifications T est-port output characteristics Frequency characteristics Range 300 kHz to 3 GHz Option 006 300 kHz to 6 GHz Resolution 1 Hz Stability 4 ±7.
15 HP 8753ET specifications T est-port input characteristics (continued) External source mode 1 (CW time sweep only) Frequency range 300 kHz to 6 GHz R-channel input requirements 2 Power level 0 to -2.
16 HP 8753ET/ES supplemental characteristics Measurement Number of display channels Four display channels available. Number of measurement channels T wo primary and two auxiliary measurement channels available. Measurement parameters HP 8753ET : Reflection, transmission, A, B, R, A/R, B/R, A/B.
17 HP 8753ET/ES supplemental characteristics (continued) Sweep trigger Set to either continuous, single, group sweep, or exter- nal trigger . Set external trigger to take a complete sweep or to measure individual points in a frequency , power or list sweep.
18 HP 8753ET/ES supplemental characteristics (continued) T race functions Display data Display current measurement data, memory data, or current measurement with measurement and memory data simultaneously . T race math V ector division or subtraction of current linear mea- surement values and memory data.
19 HP 8753ET/ES supplemental characteristics (continued) Frequency offset on/of f Sets the RF source to be swept at a fixed offset fre- quency above the receiver as required in a swept RF/IF , fixed LO, mixer test. Service menu Select the desired service test, service diagnostic, ser- vice or verification mode.
20 General characteristics Front panel connectors HP 8753ES test ports (without Option 011) Connector type 7 mm, precision Impedance 50 ohms (nominal) HP 8753ES Option 011 test ports Connector type T .
21 Environmental characteristics General conditions RFI and EMI susceptibility: defined by VDE 0730, CISPR Publication 11, and FCC Class B Standards. ESD (electrostatic discharge): must be eliminated by use of static-safe work procedures and an anti-static bench mat.
22 T est set specifications for Option 011 HP 85046A/B S-parameter test sets The HP 85046A/B S-parameter test sets provide the capability to measure reflection and transmission char- acteristics (including S-parameters) of two-port devices in either direction with a single connection.
23 HP 85047A S-parameter test set The HP 85047A S-parameter test set provides the capability to simultaneously measure the reflection and transmission characteristics of two-port devices in either direction with a single connection.
24 Accessories Calibration kits V ector accuracy enhancement procedures require that the systematic errors of the measurement system be characterized by measuring known devices (standards) on the system over the frequency range of interest.
25 HP 85038 family of calibration kits The HP 85038A calibration kit contains open circuits, short circuits, and terminations with both male and female 7-16 connectors. More economical versions of this kit are available: the HP 85038M contains only male devices, and the HP 85038F provides only female devices (see following table).
26 V erification kits Measuring known devices other than the standards used in calibration is an easy way to verify the proper operation of an HP 8753ES measurement system. HP offers verification kits which include devices, with data, for verifying the error -corrected measurements of an HP 8753ES and 50-ohm test sets.
27 HP 11852B 50-ohm to 75-ohm minimum loss pad (continued) Connectors 50-ohm type-N (f) to 75-ohm type-N (m) standard Option 004, 50-ohm type-N (m) to 75-ohm type-N (f) Dimensions 14-mm D x 70-mm L (0.
28 HP 8347A RF amplifier The HP 8347A RF amplifier delivers increased power across a 300 kHz to 3 GHz frequency range. The HP 8347A provides leveled output power without using an external coupler and detector , since these parts are built-in. The external ALC can be directly connected to the external AM input on the HP 8753ET/ES.
デバイスHP (Hewlett-Packard) 8753ETの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) 8753ETをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) 8753ETの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) 8753ETの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) 8753ETで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) 8753ETを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) 8753ETの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) 8753ETに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) 8753ETデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。