HP (Hewlett-Packard)メーカーBL460cの使用説明書/サービス説明書
ページ先へ移動 of 30
HP ProLiant BL460c Server Blade 1. Access Panel 6. Smart Array E200i Controller (optional battery-backed write cache) 2. Up to two Intel Dual-Core Xeon™ processors 7. Two Mezzanine slots (accommodates one Type I mezzanine and one Type II mezzanine card) 3.
NOTE: 8 GB Fully Buffered DIMM option kit will be available shortly. Today's maximum is 16 GB utilizing 2 GB DIMMs in a 4 GB Fully Buffered DIMM option kit. Storage Controller: Integrated Smart Array E200i RAID controller with 64 MB cache (with optional battery-backed write-cache with an upgrade to 128 MB cache(BBWC)).
Processor Dual-core Intel Xeon 5063 Processor (3.2 GHz MV, 1066 FSB) Mid-Voltage Dual-core Intel Xeon 5050 Processor (3.0 GHz, 667 FSB) * NOTE: Intel 5000 series processors are 64-bit, Dual-core, support Hyper Threading, and Intel VT. NOTE: *Offered through CTO (Factory Integrated Models) only.
Graphics Resolution Supported Resolution Color Depths Depths 1280 x 1024, 16.7M, 64k, 256.16 1024 x 768, 16.7M, 64k, 256,16 800 x 600, 16,7M, 64k, 256, 16 640 x 480, 16,7M, 64k, 256, 16 Fibre Channel on the HP ProLiant BL460c server blade Two optional Fibre Channel HBAs are supported by the HP ProLiant BL460c.
Insight Control Data Center Edition Insight Control Data Center Edition delivers foundation management for HP BladeSystem lifecycles, including hardware resource deployment, health monitoring, software version control, performance monitoring and vulnerability scanning and patch management.
Insight Management Agents and The HP System Management Homepage are included on ProLiant Support Packs, and can also be installed using the server profiles provided with the ProLiant Essentials Rapid .
OS Support Microsoft Windows 2000 Server Microsoft Windows 2000 Advanced Server Microsoft Windows Server 2003, Standard Edition Microsoft Windows Server 2003 R2, Standard Edition Microsoft Windows Ser.
Intelligent Manageability Integrated Lights-Out 2 Standard Blade Edition (iLO 2) Virtual KVM(Text and Graphical modes) Virtual Media (CD ROM ,floppy and USB flash drive) Virtual Power Button Control I.
RoHS Compliant For Resellers in countries/regions with RoHS legislation (see NOTE) (e.g. EU, China, etc.) The use of the noted material in a solution and subsequent resale of that solution will result in the solution no longer meeting the requirements of RoHS legislation.
NOTE: For more information regarding the Blade service portfolio visit our worldwide web site on the internet at: http://h20219.www2.hp.com/services/cache/81725-0-0-225-121.html NOTE: For more information on HP Care Pack services, contact any of our worldwide sales offices or resellers or visit our worldwide Web site on the internet at: http://www.
HP ProLiant BL460c 5063 DC, 2GB (1P) 404664-B21 Processor(s) (1) Dual-core Intel Xeon 5063 Processor (3.2 GHz, MV, 1066 FSB) Cache Memory 2x2MB Level 2 cache memory Memory 2 GB (2 x 1 GB) PC2-5300, FB.
NOTE: For Configure to Order requirements within EMEA region, please consult local Sales Contact. NOTE: HP does not allow factory integration of options into standard models listed above. Configure-to-order servers must start with a CTO Chassis. NOTE: This product offering does not support HP Factory Express Server Configuration Level 1.
Step 4: Choose Additional Options for Factory Integration NOTE: For additional options, including server blade enclosure with enhanced backplanes, interconnect options and power subsystem options; please refer to the "Options" section below.
ProLiant Essentials Value Pack Software ProLiant Essentials Integrated Lights-Out Select Pack ProLiant Essentials Integrated Lights-Out Select Pack, 1 server License 413119-B21 ProLiant Essentials Int.
NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs. Refer to http://www.hp.com/servers/proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information. NOTE: For more information regarding ProLiant Essentials Software, please see the following URL: http://www.
HP ProLiant BL460c - Fibre Channel Adapter Emulex LPe1105 FC Dual Channel 4Gb, PCI-E-to-Fibre Channel Host Bus Adapter 403621-B21 QLogic QMH2462 4Gb FC HBA for HP c-Class BladeSystem 403619-B21 NOTE: .
HP StorageWorks Modular Smart Array 1000 HP StorageWorks Modular Smart Array 1000 201723-B22 NOTE: Please see the Modular Smart Array 1000 QuickSpecs for additional options and configuration information at http://h18000.www1.hp.com/products/quickspecs/11033_div/11033_div.
HP Rack 5000 Series (Metallic Carbonite) HP5642 Rack-Unassembled 358254-B21 NOTE: Please see the HP Rack 5642 QuickSpecs for additional part numbers and Technical Specifications such as height, width, depth, weight, and color: http://h18000.www1.hp.com/products/quickspecs/12074_div/12074_div.
HP Rack 10000 Series (Graphite Metallic) 10642 (42U) Infrastructure Rack (Low Voltage) 379006-001 10642 (42U) Infrastructure Rack (High Voltage) 379005-001 HP S10614 (14U) Rack Cabinet - Shock Pallet 292302-B22 HP Rack 10842 (42U, 800mm wide) Rack Cabinet - Pallet NOTE: Server Blade Enclosures must be field integrated into the 10842 racks.
Monitors and Keyboards TFT7210R Rack Mounted 17" Monitor NOTE: For a complete list of Monitors please view the following URL: http://www.hp.com/go/kvm 348373-B21 TFT7600 Rackmount Keyboard Monito.
HP KVM Switch Options HP BladeSystem Cat 5 KVM Interface Adapter AF100A Server Console Switch (KVM), 0 x 1 x 8 port 336044-B21 Server Console Switch (KVM), 0 x 2 x 16 port 336045-B21 PS/2 Interface Ad.
NOTE: HP Care Pack services for the c7000 Enclosure cover the enclosure, power supplies and fans. HP qualified rack options are covered by these services when installed within the same rack.
installation verification testing and customer orientation. Hardware deployment covers the installation of a single BladeSystem enclosure that include server blades (up to 16), Ethernet network interconnect, and power options.
ProLiant Essentials Operating Environment, - 5 Day, 9x5,1 year, 50 incident UE119E ProLiant Essentials Operating Environment, - 5 Day, 24x7,1 year,50 incident UE120E ProLiant Essentials Operating Envi.
D IMM installation guidelines: All DIMMs must be PC2-5300 Fully Buffered DIMMs (DDR2-667) running at 533 MHz. 1. Both DIMM slots in a memory bank must be populated. 2. Banks must be populated in sequential alphabetic order, starting with bank A. 3. Both DIMMs in a memory bank must be identical.
1-2 2 x SFF SAS or SATA Hot Plug Hard Drives Hard Drives SAS Hard Drive Quantity Supported Position Supported Controller 36 GB 10,000 rpm SAS 72 GB 10,000 rpm SAS 2 1-2 Smart Array E200i Controller Se.
Tape Libraries NOTE: For complete listing of tape library compatibility see http://www.hp.com/go/ebs . Quantity Supported Position Supported Controller HP StorageWorks Tape Libraries MSL2024 (Ultrium .
NOTES: To review typical system power ratings use the Active Answers Power Calculator which is available via the online tool located at URL: http://h30099.www3.hp.com/configurator/calc/Power%20Calculator%20Catalog.xls To drill down to calculators: Click on: "ProLiant Servers" Click on the Server of interest.
HP ProLiant BL460c Server Blade Dimensions Height 2.207 in (5.61 cm) Depth 20.058 in (50.95c m) Width 7.154 in (18.17 cm) Weight Maximum 14.20 lb (6.44 kg) Temperature Range * Operating 50°F to 95°F.
Embedded Dual NC373m Multifunction Gigabit NICs Network Interface 1000Base-T Compatibility IEEE 802.3ab 1000Base-T Data Transfer Method PCI Express, four lanes (x4) Network Transfer Rate (Theoretical .
デバイスHP (Hewlett-Packard) BL460cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) BL460cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) BL460cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) BL460cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) BL460cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) BL460cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) BL460cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) BL460cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) BL460cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。