1. Dual 550W Hot Plug Redundant Power 2. 2U (3.5" Height) rack form factor 3. PCI-X Riser Cage, Three 64-bit PCI-X slots 4. Six memory DIMM slots 5. Tool-less "Snap in" Rail Solution 6. Hood 7. LEDs 8. Slimline Removable media Bay with 24x CD-ROM installed 9.
on-site limited global warranty. Certain restrictions and exclusions apply. Pre-Failure Notification on processors, memory, and SCSI hard drives. QuickSpecs HP ProLiant DL560 Overview DA - 11595 Worldwide QuickSpecs — Version 46 — 12.
Processor One of the following depending on Model (2P) Intel Xeon Processor MP 3.0 GHz/4MB (Expandable to 4 processors) (2P) Intel Xeon Processor MP 2.7 GHz/2MB (Expandable to 4 processors) (1P) Intel Xeon Processor MP 2.2 GHz/2MB (Expandable to 4 processors) (1P) Intel Xeon Processor MP 2.
Storage Data Protection The Battery-Backed Write Cache (BBWC) Enabler protects up to 64-MB write cache memory from hard boot, power, controller, or system board failures.
SmartStart SmartStart is a tool that simplifies server setup, providing a rapid way to deploy reliable and consistent server configurations. For more information, please visit the SmartStart Web site at http://www.hp.com/servers/smartstart . SmartStart version supported (minimum): SmartStart 6.
management and control of virtual machines from Microsoft and VMware. Integrated approach provides the ability to manage both physical and virtual resources from a single management console. NOTE: Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs.
Availability Standard Advanced ECC functionality detects and corrects single bit and specific multi-bit memory errors (4bit and 8bit) while using industry standard registered DIMMS.
Security Power-on password Keyboard password Diskette drive control Diskette boot control Network Server Mode Security Provision Serial interface control Administrator's password Disk configurati.
OS Support Microsoft Windows 2000 Windows Server 2003 Novell NetWare LINUX (Red Hat, SuSE) UnitedLinux VMware Virtualization Software NOTE: For a more complete and up-to-date listing of supported OSs and versions, please visit our OS Support Matrix at: http://www.
Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration, customization, integration and deployment services for HP servers and storage products. Customers can choose how their factory solutions are built, tested, integrated, shipped and deployed.
DL560R01 X3.0GHz- 4MB, 1024MB (2P) 346921-xx1 Processor(s) (2) Intel Xeon Processors MP at 3.0 GHz standard (up to 4 supported) Cache Memory 4MB Integrated Level 3 Cache Memory 1024 MB 200-MHz (DDR) S.
DL560R01 X2.2-2MB, 1024MB (1P) 346919-xx1 Processor(s) (1) Intel Xeon Processor MP at 2.2 GHz standard (up to 4 supported) Cache Memory 2MB Integrated Level 3 Cache Memory 1024 MB 200-MHz (DDR) SDRAM .
ProLiant Essentials Value Pack Software ProLiant Essentials Integrated Lights-Out Advanced Pack ProLiant Essentials Integrated Lights-Out Advanced Pack, 1 server Featuring: sophisticated virtual administration features for ultimate control of servers in the data centers and remote sites.
virtual machine. Or this license can be used to migrate a virtual machine from one virtualization layer i.e. VMware GSX to a different virtualization layer such as VMware ESX or Microsoft Virtual Server 2005. NOTE: For additional ProLiant Essentials Virtualization Management Software License Kits please see the QuickSpecs at: http://h18000.
Hard Drives Ultra320 SCSI - Universal Hot Plug 300-GB 10,000 rpm U320 Universal Hard Drive (1") 350964-B22 146.8-GB 10,000 rpm U320 Universal Hard Drive (1") 286716-B22 72.8-GB 10,000 rpm U320 Universal Hard Drive (1") 286714-B22 146.8-GB 15,000 rpm U320 SCSI Hard Drive (1") 347708-B22 72.
(SCSI Adapter) http://h18000.www1.hp.com/products/quickspecs/11555_div/11555_div.HTML (U320 Adapter) Communications HP NC310F PCI-X 1000SX Gigabit Server Adapter 368169-B21 HP NC1020 PCI 1000T Gigabit.
HP StorageWorks 1U Rack-Mount Kit NOTE: The 1U Rack-mount Kit can support up to (2) half-height tape drives and compatible with multiple Single-Ended and LVD SCSI tape drives including the DAT 24, DAT 40, DAT 72, DLT VS80, DLT VS160, Ultrium 215, Ultrium 232 and Ultrium 448 tape drives.
Tape Libraries HP StorageWorks MSL2024 Tape Library HP StorageWorks MSL2024 1 Ultrium 960 Drive Library AG115A HP StorageWorks MSL2024 1 Ultrium 448 Drive Library AG116A HP StorageWorks MSL2024 2 Ultr.
Cluster Options ProLiant Cluster Starter Kit 364023-B21 NOTE: For additional information regarding the ProLiant Cluster Starter Kit please see the following QuickSpecs at: http://h18000.www1.hp.com/products/quickspecs/11935_na/11935_na.html (North America) http://h18000.
HP StorageWorks Modular Smart Array 20 HP StorageWorks Modular Smart Array 20 NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies. 335921-B21 HP StorageWorks Modular Smart Array 20 Starter Kit NOTE: Rack-mountable 12 (SATA) drive enclosure with U320 Host connectivity, redundant power supplies.
Uninterruptible Power Systems – Rack HP UPS R1500 XR (1440VA, 1340 Watt), Low Voltage (NA) 204404-001 HP UPS R1500 XR (1500VA, 1340 Watt), High Voltage (Int’l) 204404-B31 HP UPS R1500 XR (1500VA, .
Modular Power Distribution Units 1U/0U (Up to 32 outlets) NOTE: 1U/0U mounting brackets shipped with the unit (optimized for 10000 and 9000 series racks). HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC) (NA, Japan) NOTE: This mPDU (252663-D71) may also be used to connect the low volt model of the UPS R3000 XR.
NOTE : -B21 (pallet) used to ship empty racks shipped on a truck -B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels) -B23 (crated) used for air shipm.
NOTE: Cat5e cables are required to connect Interface Adapters to Console Switches. Cat5e cables can be found at the following URL: http://www.hp.com/go/kvm .
Installation & Start-up Services Hardware Installation, Electronic U4707E Installation & Start-Up of a ProLiant server and Microsoft or Linux O/S per the Customer Description and/or Data Sheet. To be delivered on a scheduled basis 8am-5pm, M-F, excl.
HP ProLiant DL560 Standard Memory 1024 MB PC2100 Registered DDR SDRAM DIMM Memory comes installed (2 x 512 MB SDRAM) Standard Memory Plus Optional Memory Up to 9216 MB memory is available with the opt.
A 1.44-MB Diskette Drive B Ejectable: 24x IDE CD-ROM (Slimline) 0-1 Wide Ultra3/Ultra320 Drive Cage Drive Support Quantity Supported Position Supported Controller Slim Line Drives 1.
determine configuration requirements Modular Smart Array 1500 cs Please see the Modular Smart Array 1500 cs QuickSpecs below to determine configuration requirements External Please see the Modular Smart Array 1500 cs QuickSpecs (URL below) for the latest list of supported HBAs Modular Smart Array 1000: http://h18000.
Ultrium 230 Ultrium 232 Ultrium 448 Ultrium 460 DAT 40 DAT 72 DLT VS80 DLT VS160 SDLT 320 Alternate OS HP StorageWorks Tape Drives, External Ultrium 960 SDLT 600 1 drive per SCSI channel External 64-B.
Part Number 280126-001 Spare Kit 280126-B21 Operational Input Voltage Range (V rms) 90 to 264 Frequency Range (Nominal) (Hz) 47 to 63 (50/60) Nominal Input Voltage (Vrms) 100 115 208 220 230 240 Max Rated Output Wattage Rating 550 550 550 550 550 550 Nominal Input Current (A rms) 7.
System Unit Rack Chassis Footprint (HxWxD) 3.38 x 17.50 x 25.75 in (8.59 x 44.45 x 65.41 cm) Weight Maximum (2 Power Supplies, 2 Hard Drives) 60 lb (27 kg) Minimum (No hard drives installed, one power.
24X Max (or higher) IDE CD-ROM Drive Slimline Disk Applicable Disk CD-DA, CD-ROM (Mode 1 and 2) CD-XA, CD-I (Mode 2, Form 1 and 2) Photo CD (Single and Multi-session) Mixed Mode (Audio and Data combined) Capacity 540 MB (Mode 1, 12 cm) 650 MB (Mode 2, 12 cm) Diameter 4.
CD-I (mode 2) CD-I Ready CD-Bridge Capacity DVD-ROM DVD-SL 4.7 GB/side DVD-DL 8.5 GB/side Double Sided 9.40 GB/side DVD-R 3.95 GB/side DVD-RAM 2.6 GB/side and 5.
Integrated Lights-Out Standard (integrated on system board) Architecture 32-bit PCI-based health and remote management ASIC (Application Specific Integrated Circuit) Processor 32-bit RISC processor core running at 66 MHz Upgradability Option firmware upgradable via flash ROM.
Battery-Backed Write Cache Yes, with installation of Battery-Backed Write Cache Enabler, up to 64MB RAID Support 0, 1 Logical Drives (maximum) Maximum = total number of drives Online Configuration Yes.
デバイスHP (Hewlett-Packard) DL560の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) DL560をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) DL560の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) DL560の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) DL560で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) DL560を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) DL560の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) DL560に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) DL560デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。