FuturePlus Systems Corporation LOCAL BUS PCI Scope Preprocessor Users Manual-FSPCI64S For Hewlett-Packard Logic Analysis Systems Revision 1.0 FuturePlus Systems and PCI Scope is a trademark of FutureP.
2 HOW TO REACH US 4 PRODUCT WARRANTY 5 Limitation of warranty 5 Exclusive Remedies 5 Assistance 6 INTRODUCTION 7 How to Use This Manual 7 ANALYZING THE PCI LOCAL BUS 8 Duplicating the Master Diskette .
3 Standards Supported 15 Power Requirements 15 MultiProbe Pods required 15 Signal loading 15 Operations 16 Environmental Temperature 16 Altitude 16 Humidity 16 Testing and Troubleshooting 16 Servicing.
4 How to reach us FuturePlus Systems can be reached at: FuturePlus Systems Corporation 36 Olde English Road Bedford, NH 03110 TEL:603-471-2734 FAX:603-471-2738 Internet: 71035.3052@compuserve.com WEB:www.futureplus.com FuturePlus Systems is represented in Japan by: ANDOR Systems Support Co.
5 Product Warrant y This FuturePlus Systems product has a warranty against defects in material and workmanship for a period of 1 year from the date of shipment. During the warranty period, FuturePlus Systems will, at its option, either replace or repair products proven to be defective.
6 SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR ANY OTHER LEGAL THEORY. Product maintenance agreements and other customer assistance agreements are available for FuturePlus Systems products.
7 Introduction The PCI Scope Preprocessor module provides a complete interface between any PCI add-in slot and the HP MultiProbe system. The Preprocessor interface connects the signals from the PCI Local bus to the inputs of a 208 PQFP package used as the MultiProbe connection point.
8 Analyzing the PCI Local Bus This chapter introduces you to the PCI Scope Preprocessor and lists the minimum equipment required and accessories supplied for PCI Local Bus analysis. Before you use the PCI Preprocessor software, make a duplicate copy of the master diskette.
9 • An Oscilloscope • The PCI Scope Preprocessor Product • A PCI target bus This operating manual uses the same signal notation as the PCI LOCAL BUS SPECIFICATION - REVISION 2.1. That is, a # symbol at the end of a signal name indicates that the signal’s active state occurs when it is at a low voltage.
10 PCI_MUL.DUT and PCI.ADP from your PCI Scope Preprocessor diskette to that directory. 3. Access the configuration menu of the MultiProbe Control card. 4. Select POD setup for the POD that will be connected to the Scope Preprocessor. 5. On the next menu select #2 Specify POD adapter and then select the file PCI.
11 Analog Analysis Since the PCI Scope Preprocessor interface contains only passive matching terminators it introduces negligible skew to the PCI Local Bus signals. The following procedure describes the major steps required to perform analog analysis measurements with the PCI Scope Preprocessor module.
12 Select the oscilloscope for each MultiProbe output using the Select Signals menu of the MultiProbe control module. 1. Access the Select Signals menu. 2. Select the scope for each output a) Choose the output (Output 1 or Output 2) of the control module that is connected to the pod that is attached to the PCI Scope Preprocessor.
13 Using an HP16534A oscilloscope If you are using an HP 16534A oscilloscope, then follow this procedure. 1. Access the oscilloscope menus. To view your measurements with an HP16534A oscilloscope, you need to exit the MultiProbe Control menus, then enter the oscilloscope menus.
14 When the PCI Personality Adapter 101 is not in use, keep it in its original container. The file PCI.ADP matches the configuration of the PCI Personality Adapter and configures the MultiProbe for PCI Analysis.
15 General Information This chapter provides additional reference information including the characteristics and signal connections for the PCI Scope Preprocessor module. The following operating characteristics are not specifications, but are typical operating characteristics for the PCI Scope Preprocessor module.
16 information on the electrical loading of the MultiProbe Pod refer to your Hewlett-Packard MultiProbe specification. All PCI Local Bus operations supported.
17 The below table shows the connection from the PCI Local Bus to the PQFP package that acts as the MultiProbe Contact point. If the pin is not listed it is Grounded.
18 AD26 75 AD25 77 AD24 79 C/BE3# 81 AD23 83 AD22 85 AD21 87 AD20 89 AD19 91 AD18 93 AD17 95 AD16 97 C/BE2# 99 FRAME# 101 IRDY# 103 TRDY# 105 DEVSEL# 107 STOP# 109 LOCK# 111 SDONE 113 PERR# 115 SBO# 1.
19 AD09 137 C/BE0# 139 AD08 141 AD07 143 AD06 145 AD05 147 AD04 149 AD03 151 AD02 153 AD01 155 AD00 157 ACK64# 159 REQ64# 161 C/BE7# 163 C/BE6# 165 C/BE5# 167 C/BE4# 169 PAR64 171 AD32 173 AD33 175 AD.
20 AD45 199 AD46 201 AD47 203 AD48 205 AD49 207.
デバイスHP (Hewlett-Packard) FSPCI64Sの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) FSPCI64Sをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) FSPCI64Sの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) FSPCI64Sの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) FSPCI64Sで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) FSPCI64Sを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) FSPCI64Sの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) FSPCI64Sに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) FSPCI64Sデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。