HP P4459A 8-Port Fibre Loop Switch Installation & Operation Guide HP Part Number 5971-0861 Printed in February 2001.
Notice The information contained in this document is subject to change without notice. Hewlett-Packard makes no warra nty of any kind with r egard to this material, including, but not limited to , the implied warra nties of merchantability a nd fitness fo r a particular pu rpose .
HP P4459A 8-Port Fib re Loop S witch I nstall ation & O peration Guide iii Safety Instructions The following sections describe the symbols used on the fibre loop switch and within this guide and a.
iv HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Symbol s in T ext The following symbols are used in the following formats to highlight special messages throughout this guide: Note: This format is u sed to highli ght infor mation of importa nce or special inte rest .
Content s Conte nts ... ...... ..... ...... ..... ...... ..... ...... ..... ...... ..... ...... ..... ...... ..... ...... ..... ...... ..... ....... .... ..... .... v Pre face ...... .... ....... .... ....... .... ....... .... ....... .... ....... ...
vi HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Appendix A: Fibre Loop Switch Functi onal Specifications ... ....... ....... ......... .......... .. 37 Swit ching ....... .... ....... .... ....... .... ....... .... .....
vii Preface The fibre loop switch provides an afforda ble entry-level SAN switch with multiple connectivity options. Thi s guide provides information about the features and capabilities of the fibre loop switch, and how to install it.
viii HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Related W eb Sites These web sites, among others, provide significant information regarding SANs and the Fibre Channel protocol. T able 1: Related Websites Site URL ANSI http:/ /www .
1 Chapter 1 Introducing the HP P4459A 8-Port Fibre Loop Switch The following sections of this chapter provide an overview of the features and functions of the fibre loop switch: • Fibre Loop Switch Features • Switching Operation Fibre Lo op Switch Features The fibre loop switch features an integra l 12Gb/sec.
2 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Figure 1: Front V iew of the Fibre Loop Switch Front Pa nel L EDs In addition to the port connectors, the front panel of the fibre loop switch contains LEDs that provide diagnostic information for both switch and port status, and an IEC power plug connector.
Introduci ng the HP P4459A 8-Po rt Fibr e Loop Swi tch 3 Figure 2: Fibre Loop Switch front p anel Table 1 describes the operation of the switch LEDs and Table 2 de scribes the operation of the port LEDs on the front panel of the fibre loop switch.
4 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Switching Operation The fibre loop switch implements the Fibre Channel Arbitrated Loop protocol. It provides concurrent connections to the storage a rea network (SAN) without changing the FC-AL interface, which most SAN end-node devices normally communicate.
Introduci ng the HP P4459A 8-Po rt Fibr e Loop Swi tch 5 wish to communicate. The addition of a hub, as shown in the center of the same figure, merely allows the cables from each node to go to a centralized location, such as a wiring closet where the hub is located.
6 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de • If node A is free, node C’ s data is forwarded dire ctly to node A without interference. That is, the messages do not circulate through e ach device on the loop and so latency savings on this transaction are also gained.
Introduci ng the HP P4459A 8-Po rt Fibr e Loop Swi tch 7 that it is ready to participate by sending a LIP. Obviously, this interrupts any traffic in progress on that switch port, or on another switch port that is involved in a connection with a device on that switch port.
8 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de.
9 Chapter 2 Inst alling the Fibre Loop Switch The following sections of this chapter provide detailed instructions for installing a fibre loop switch: • Unpacking the Fibre Loop Switch • Installin.
10 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Installing a nd R emov ing G BIC s in the F ibre Loop Swit ch Each port that you plan on using on the fibre loop switch must be configured with an HP-supported GBIC to provide media connectivity.
Installing the Fibre Loop Switch 11 Figure 4: GBIC Orie nt ation 3. Slide the GBIC thr ough the port door and plu g it into the 20-pin connector (not visible) on the host cir cuit board until it is firmly seated. If the GBIC does not install easily into the port, do not force it.
12 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de 2. Squeez e the latc h levers (on the G BIC) together and pull the G BIC straight out. Rack Mounti ng th e Fibre Lo op Switch The following sections provide information and procedures on how to rack mount the fibre loop switch.
Installing the Fibre Loop Switch 13 Rack Installati on Basics Always keep the following safety and environmental issues in mind: • Maximum Rec ommended Ambient T emperature: The max imum recommended ambient temperature of the room is 35°C (95°F).
14 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de instructions that come with your rack or HP NetServer, or refer to the f ollowing web site: http://www.hp.com/racksolutions Figure 5 and Figure 6 present a visual summary of the switch’s rack-mounting hardware.
Installing the Fibre Loop Switch 15 Figure 6: Mounting in HP Rack System/E and HP Rack System/U Racks Tools Required To install the switch in an HP rack, y ou need a T25 Torx driver a nd a #1 Phi llips- head screwdri ver.
16 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de • St ep 4: Attach the Sleeves to the Front Rack Columns • St ep 5: Attach the Switch Rai ls to the Switch C hassis .
Installing the Fibre Loop Switch 17 Figure 7: Marking Holes and Att aching Barrel Nut s on HP Systems Racks EIA Unit Left Rear Rack Column Right Rear Rack Column Barrel Nuts.
18 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Figure 8: Marking Holes and Att aching Barrel Nut s on HP Rack System/E a nd HP Rack System/U Racks Step 2: Mar k the Rac.
Installing the Fibre Loop Switch 19 2. Place two barrel nuts on each of the rear rack columns at the holes you marked, as shown in Figur e 7 and Fi gure 8. 3. For HP Systems racks only , attach one barrel nut to each of the fr ont rack colu mns at the holes you marked.
20 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Figure 9: Inst alling S p acers on HP Rack System/E and HP Ra ck System /U Racks Step 4: Attach t he Sle eves to the Fron.
Installing the Fibre Loop Switch 21 Figure 10: Identifying Switch Rails and S leeves (Or iented fo r HP Racks ) 2. Identify the six T orx screws. Sleeve Switch Rail Sleeve Flange Switch Rail Flange.
22 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Figure 1 1: Attaching Sleeves to an HP Systems R ack Left Front Rack Column Right Front Rack Column Rack Nut Sleeve Sleev.
Installing the Fibre Loop Switch 23 Figure 12: Att aching Sleeves t o HP Rack S ystem/E and HP Rack System/U Ra cks 3. Position one sleeve on the inside of the rack front column with the sleeve’ s flange side toward the r ack column, as shown in Figur e 1 1 or Figure 12.
24 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Step 5: Atta ch the Swi tch R ails to t he Swit ch Chassi s 1. Remove the two side screws (one on each side of the switch chassis) that r etain the cover , as shown in Figur e 13.
Installing the Fibre Loop Switch 25 Step 6: Install the sw itch Have the remaining four Torx screws ava ilable as you install the switch. 1. Pick up th e switch chassis ( with the switch rai ls installed) with the open switch rail ends away from you. Carry it to the r ear of the rack.
26 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Figure 14: Installing the Swit ch into an HP Systems Rack Left Rear Rack Column Left Front Rack Column Right Rear Rack Co.
Installing the Fibre Loop Switch 27 Figure 15: Installing the Switch into an HP Ra ck System/E or HP Rack System/U Rack 5. Attach the other switc h rail to the other rear rack column in the same way . 6. Use the T25 driver in a couple of passes to tighten all six scr ews that you installed in the rack columns.
28 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Plugging in the other end of the power cord will apply power to the switch. You can do either of the following: • Connect the other end of the power cord to the power re ceptacle on the rack, which means you will hot-plug devices to the switch.
Installing the Fibre Loop Switch 29 Powe ring up a S ystem When bringing up an FC-AL system, first make all the connections with the equipment powered down, then turn on the fibre loop switch before turning on any other operating component. The fibre loop switch does not have an On/Off switch.
30 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de copper cabling. Table 3 provides the specifications for optical cable support and Table 4 provides the specifications for copper cable support.
31 Chapter 3 Fibre Loop Switch T roubleshooting The following sections of this chapter provide information to help you troubleshoot problems with your fibre loop switch: • General Maintenance Consid.
32 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de • Never insert foreign objects into optical transmit and receive ports.
Fibre Loop Switch Tr oubles hooting 33 T able 5: Reading The Power , Fault, and Initialization LEDs T able 6: Reading The Port LEDs Label LED Color/ Patter n Interpretation Possible Causes Power Green/ON The unit is connected to an AC powe r sour ce and the interna l power supply is func tionin g.
34 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Reset Button Use the reset button with caution. The Reset button on the front panel of the switch resets the internal con trol microproc essor of the switch. Sometime s a reset clears a problem that appear s to be the result of an unidentified error.
Fibre Loop Switch Tr oubles hooting 35 • Keep unused GBIC connectors covered with the plugs that are shipped with them to prevent contamination from obscuring or attenuating the light sig- nals. Fibre Chan nel Cables The fibre loop switch uses Fibre Channel cable s to communicate with cascaded and end-node devices.
36 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de.
37 Appendix A Fibre Loop Switch Functional Specifications Switch ing Switch Backplane Bandwidth.......... 12 Gigabits per second Switching Mode...............................Non-Blocking Port Speed ........................................1.0625 Gigabits per second Communication Modes .
38 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Electri cal S pecifi cati ons AC V oltage ...................................... 100–240 V AC autosensing Frequency ........................................50 to 60 Hz Rated Input Current .
Fibre Loop Switch Functional Specifications 39 European Union (EU) ......................EN 55022: 1994 +A1 +A2, Class A EN61000-3-2: 1995 EN61000-3-3: 1995 EN 55024: 1998 Japan ................................................VCCI V3: 1997, Class A JEIDA Guideline for the suppression of harmonics: 1993 Australia/New Zealand .
40 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de.
41 Appendix B Regulatory Information Regulatory Notices Elect romagnet ic Compl iance Electromagnetic Compatibility (EMC) requirements have been established in many countries to regulate the radio freque ncy energy generated by Information Technology Equipment (ITE).
42 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Notice for United States Class A E quipm ent This equipment has been tested and found to comply with the limits for Class A digital devices, pursuant to Part 15 of the FCC (Federal Comm unications Commission Rule s).
Regulatory Information 43 Notice for Korea Class A W arning Please note that this equipment has been approved for business purposes with regards to electromagnetic interf erence, if purchase d in error for use in residential area, you may wish to exchange the equipment where you purcha sed it.
44 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Notice for European Unio n Radio Frequency Emissions Warning for Acc essories This product has been found to comply with CISPR 22 Cl ass A EMC emission limits.
Regulatory Information 45 Declaration of Conformity (US and EU) DECLARA TION OF CONFORMITY according to ISO/IEC Guide 22 and EN 4 5014 Manufacture r's/Supplier Name: Hewlett-Packard Company Manuf.
46 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de Regu lator y No tice s - Pro duct Safety This product may be equipped with a Hewlett-Packard Optical GBIC containing a laser. In which case the GBIC is a Class 1 Laser Product per US/FDA/CDRH (21 CFR) and per IEC-825-1 (EN60825-1 and A11).
Regulatory Information 47 Laser Safety - Germany VORSICHT Diese Gerät enthält ein Laser-System und ist als "LASER PRODUKT DER KLASSE 1"klassifiziert. Für den richtigen Gebrauch dies es Modells die Bedienungsanleitung so rgfältig durchlesen und als Referenz aufbewahren.
48 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de CLASS 1 LASER PRODUCT This Fibre Loop Switch Unit is classified as a CLASS 1 LASER PRODUCT .
49 Appendix C W arranty and Support The hardware warr anty below applies to components purchased as accessories. If your component was factory installed as part of a n HP Netserver model, refer to the HP Netserver Warranty and Service /Support Booklet for the warranty limitations, customer res ponsibilities, and other terms and conditions.
50 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de notice of such defects during the warranty period, HP or Reseller will either, at its option, repair or replace products that prove to be defective.
Warran ty and Suppo rt 51 Worl d Wi de Web On the World Wide Web go to: http://netserver.hp.com/netserver/.
52 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opera tion Gui de.
53 Glossary This glossary contains terms and acronyms that may be found in this documentation. AL_PA Arbitrated Loop Physical Address. The low-order byte of a 3-byte Fibre Channel Source/Destination ID field that defines an address hierarchy. This is also called a Loop ID.
54 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opear tion Guid e Bandwidth The amount of data per second that can be transferred from one devic e to another. Bandwidth limi ts are s et by a com bination of spe ed of transf er, capa city of the pipe, number of pipes, and overhead of sending the data.
Glossary 55 D_ID Destination ID. A Fibre Channel Addre ss of a frame de fining the destination node for that f rame. Diplex Communications In addition to full duplex communications between a pair of nodes, a node ca n receive from another node, while simultaneously transmitting to a third node independently.
56 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opear tion Guid e FC-0 The set of Fibre Channel standards that address media (optics, copper, conne ctors), and physical signalling over that media (signal rates and timing, signal quality, power, jitter, etc.
Glossary 57 Fibre Channel (FC) An ANSI T11 standard which pr ovides high-speed, high-r eliability data transfers among computing devices, storage devices, a nd networked equipment. It defines a bi-directional, full-duplex serial data channel at speeds of 1 Giga bit per second and higher, over distances up to 30 km.
58 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opear tion Guid e Full Duplex Communications A pair of nodes able to both simultaneously send and receive data between eac h other for an aggregate of 2 Gbps, effectively doubling the communications rate between the two nodes.
Glossary 59 LILP Loop Initialization Loop Position map is the accumulation of all of the information reported in the LIRP frames. It is optionally sent out by the initialization master at the end of the i nitialization se quence.
60 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opear tion Guid e L_Port Loop Port. It only has the capability to communicate over FC-AL hubs and through FL_Ports.
Glossary 61 Network A collection of interconnect ed components and the protocols and physical methods those components use to communicate. Network components consist of network elements (infrastructure components) and network attachments (devic es which use the network to communicate).
62 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opear tion Guid e Out-of-ba nd Using a separate channel for si gnaling to ensur e full bandwidth availa bility for it s primary purpose. For example, although more costly, it ensures full bandwidth availability for voice or critical data transmission.
Glossary 63 Router A device connected to two or more networks that decides to which network to se nd the data. It is often used in SANs to connect SCSI devices to Fibre Channel networks. SAN Storage Area Network. This conce pt brings networking to storage.
64 HP P445 9A 8-Port Fi bre Loop Switch In stallati on & Opear tion Guid e Star A configuration of computing devices within a LAN where each user is connected by links radiating out from a central connection point such as a hub. Switch Port A port on a device that can directly connect two devices together through switch connection.
デバイスHP (Hewlett-Packard) P4459Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) P4459Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) P4459Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) P4459Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) P4459Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) P4459Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) P4459Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) P4459Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) P4459Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。