This subchapter pertains to all HP 9000 Superdome servers (running PA-8600, PA-8700 or PA-8800 processors) for all markets. With Superdome, HP launches a new strategy to ensure a positive Total Customer Experience is achieved via industry-leading HP Services.
Service Solutions Service Solutions Service Solutions Service Solutions HP offers three pre-configured service solutions for Superdome that provide customers with a choice of lifecycle services to address their own individual business requirements.
NOTE: NOTE: NOTE: NOTE: Given that PA-8600/PA-8700 are single-core processors and PA-8800 is a dual-core processor, the columns listed in this table refer to 16-socket, 32-socket and 64-socket. This terminology refers to 16-way, 32-way and 64-way for Superdome PA-8600/PA-8700 and 32-way, 64-way and 128-way for Superdome PA 8800 systems.
There are three basic building blocks in the Superdome system architecture: the cell, the crossbar backplane and the I/O subsystem. Please note that Superdome with PA-8800 is based on a different chip set (sx1000) than Superdome with PA-8600 or PA-8700.
Cells (CPUs and Memory) Cells (CPUs and Memory) Cells (CPUs and Memory) Cells (CPUs and Memory) A cell, or cell board, is the basic building block of a Superdome system.
I/O Subsystem I/O Subsystem I/O Subsystem I/O Subsystem Each I/O chassis provides twelve I/O slots. Superdome PA-8600 and Superdome PA-8700 support I/O chassis with 12 PCI 66 capable slots, eight supported via single (1x) ropes (266 MB/s peak) and four supported via dual (2x) ropes (533 MB/s peak).
Factory Integration Factory Integration Factory Integration Factory Integration When an I/O Expansion cabinet is ordered as an upgrade to a Superdome system, it includes the factory testing and integration of any components that are ordered at the same time as the cabinet.
DVD Solution DVD Solution DVD Solution DVD Solution The DVD solution for Superdome requires the following components per partition. External racks A4901A and A4902A must also be ordered with the DVD solution. NOTE: NOTE: NOTE: NOTE: One DVD and one DAT is required per nPartition.
High Availability High Availability High Availability High Availability NOTE: NOTE: NOTE: NOTE: Online addition/replacement for cell boards is not currently supported and will be available in a future HP UX release. Online addition/replacement of individual CPUs and memory DIMMs will never be supported.
Multi-system High Multi-system High Multi-system High Multi-system High Availability Availability Availability Availability Any Superdome partition with PA-RISC processors that is protected by Service.
Supportability and management features on HP 9000 Superdome are covered in the next section. Service Processor (MP) Service Processor (MP) Service Processor (MP) Service Processor (MP) The service processor (MP) utility hardware is an independent support system for nPartition servers.
Support Management Support Management Support Management Support Management Station Station Station Station (SMS) The Support Management Station (SMS) runs the Superdome scan tools that enhance the diagnosis and testability of Superdome. The SMS and associated tools also provide for faster and easier upgrades and hardware replacement.
It is desirable, and sometimes essential for rapid time to repair to provide a reliable way to get console access that is physically close to the server, so that someone working on the server hardware can get immediate access to the results of their actions.
PA 8700 PA 8700 PA 8700 PA 8700 Hardware Requirement Hardware Requirement Hardware Requirement Hardware Requirement Customers ordering an SMS for the first time for a new PA 8700 Superdome should order the rx2600 SMS. The rx2600 SMS can also be used to manage PA8800 and Integrity Superdomes.
Console Connectivity Console Connectivity Console Connectivity Console Connectivity PA8700 Superdomes require scan and console to be on separate networks. Existing PA-8700 Superdome customers may have a Legacy UNIX SMS (e.g. A500 or rp2470) that required a separate console device.
Supports multiple, heterogeneous Superdome platforms. The Windows ProLiant SMS/Console is comprised of a ProLiant ML350 G3/G4 and a TFT5600 retractable display monitor/keyboard/mouse to enable console access. This solution also requires (and includes) a switch.
SMS/Console Connectivity SMS/Console Connectivity SMS/Console Connectivity SMS/Console Connectivity One SMS can support up to 16 Superdomes using a switch (the Windows ProLiant SMS can support Integrity Superdomes only, and the UNIX rx2600 SMS can support both Integrity and HP 9000 Superdomes).
Mixed Superdome Environments Mixed Superdome Environments Mixed Superdome Environments Mixed Superdome Environments Some important rules regarding SMS/Console support in mixed Superdome environments: 1. PA-8700 Superdomes require scan and console traffic to be isolated on separate networks 2.
HP-UX HP-UX HP-UX HP-UX HP-UX Systems Insight Manager HP-UX Systems Insight Manager HP-UX Systems Insight Manager HP-UX Systems Insight Manager is an easy-to-use multi-system management solution with web-enabled and command line interfaces.
OpenView Operations Agent OpenView Operations Agent OpenView Operations Agent OpenView Operations Agent -collects and correlates OS and application events (fee-based) OpenView Performance Agent OpenVi.
Console Considerations Console Considerations Console Considerations Console Considerations The optimal configuration of console device(s) depends on a number of factors, including the customer's.
Pre-existing SMS Pre-existing SMS Pre-existing SMS Pre-existing SMS Customers Customers Customers Customers Some customers may have an existing rp2470 or A500 SMS that required a separate console device. Typically a Unix workstation or PC was configured in these environments.
Cooling Requirements Cooling Requirements Cooling Requirements Cooling Requirements The cooling system in Superdome was designed to maintain reliable operation of the system in the specified environment as shown in the Superdome Specifications Table Superdome Specifications Table Superdome Specifications Table Superdome Specifications Table .
Uninterruptible Power Uninterruptible Power Uninterruptible Power Uninterruptible Power Supplies (UPS) Supplies (UPS) Supplies (UPS) Supplies (UPS) HP will be reselling high-end (10 kW and above) three-phase UPS systems from our partners. We will test and qualify a three-phase UPS for Superdome.
Power Protection Power Protection Power Protection Power Protection Runtimes Runtimes Runtimes Runtimes The UPS will provide battery backup to allow for a graceful shutdown in the event of a power failure. Typical runtime on the APC SL20KFB2 Silcon 3 Phase UPS varies with the kW rating and the load.
Power Management Power Management Power Management Power Management Description Description Description Description Network interface cards that provide standards based remote management of UPSs Gener.
SuperDome Configuration Guidelines/Rules SuperDome Configuration Guidelines/Rules SuperDome Configuration Guidelines/Rules SuperDome Configuration Guidelines/Rules Category Category Category Category .
Category Category Category Category Rule Index Rule Index Rule Index Rule Index Rule Description Rule Description Rule Description Rule Description Performance Performance Performance Performance 22 NOTE: NOTE: NOTE: NOTE: Only Superdome PA-8800 supports 1 GB and 2 GB DIMM sizes.
Category Category Category Category Rule Index Rule Index Rule Index Rule Index Rule Description Rule Description Rule Description Rule Description Single System Single System Single System Single Sys.
Category Category Category Category Rule Index Rule Index Rule Index Rule Index Rule Description Rule Description Rule Description Rule Description Multi-System Multi-System Multi-System Multi-System .
Power Redundancy Power Redundancy Power Redundancy Power Redundancy Superdome servers, by default, provide an additional power supply for N+1 protection. As a result, Superdome servers will continue to operate in the event of a single power supply failure.
individually. Description Description Description Description Product Number Product Number Product Number Product Number PA-8800 processor assembly (contains 4 CPUs and occupies 2 sockets) A6888A PA-.
of a true utility model in a capitalized version. To order Temporary Instant Capacity apacity on Superdome, A7067A must be ordered. For more information on Instant Capacity, please refer to the appropriate section in this guide.
For information on Superdome Server Upgrades, please refer to the Superdome Server Upgrades QuickSpec. QuickSpecs HP 9000 Superdome Servers HP 9000 Superdome Servers HP 9000 Superdome Servers HP 9000 .
Superdome Specifications Superdome Specifications Superdome Specifications Superdome Specifications SPU Description SPU Description SPU Description SPU Description Superdome 16-socket Superdome 16-soc.
HP-UX Attributes HP-UX Attributes HP-UX Attributes HP-UX Attributes Maximum CPUs per HP-UX 11i partition 16 32 64 Maximum CPUs per HP-UX 11i partition 16 32 128 Maximum memory per HP-UX 11i partition .
Regulatory Compliance Regulatory Compliance Regulatory Compliance Regulatory Compliance Safety IEC 950:1991+A1, +A2, +A3, +A4; EN60950:1992+A1, +A2, +A3, +A4, +A11; UL 1950, 3rd edition; cUL CSA C22.
Superdome I/O Expansion Superdome I/O Expansion Superdome I/O Expansion Superdome I/O Expansion (IOX) Cabinet (IOX) Cabinet (IOX) Cabinet (IOX) Cabinet Specifications Specifications Specifications Spe.
Management Includes Includes Includes Includes Parallel Card, Triple Chassis for three SmartSlots, User Manual, Web/SNMP Management Card Spare parts kits Spare parts kits Spare parts kits Spare parts kits See APC website http://www.
* Without TAX/VAT ** The time to recharge to 90% of full battery capacity following a discharge to shutdown using a load rated for 1/2 the full load rating of the UPS Supported I/O Cards with Superdom.
X.21 PCI 8 port X.25/BX.25 Advance Communications Controller Z7340A RS-232, V.35, RS-449 or X.21 25 25 25 Additional Interface Cards Additional Interface Cards Additional Interface Cards Additional In.
Copper PCI-X 133MHz 10GbE SR Fiber Adapter AB287A 16 32 64 PCI-X 4-port 1000 Base-T Gigabit Adapter AB545A 16 32 64 PCI -X 24 port 4x Fabric Copper Switch AB399A 4x Infiniband Copper 8 8 8 Multi-Funct.
C7508AZ (racked TA5300 tape and DVD chassis) C1354AZ (racked TA5500 tape chassis) Mass Storage Infrastructure Mass Storage Infrastructure Mass Storage Infrastructure Mass Storage Infrastructure FC Hub.
© Copyright 2005 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows Server 2003 are US registered trademarks of Microsoft Corporation. Intel and Itanium are US registered trademarks of Intel Corporation.
デバイスHP (Hewlett-Packard) PA-8600の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) PA-8600をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) PA-8600の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) PA-8600の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) PA-8600で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) PA-8600を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) PA-8600の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) PA-8600に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) PA-8600デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。