HP (Hewlett-Packard)メーカーR2200の使用説明書/サービス説明書
ページ先へ移動 of 61
HP R/T2 200 UP S User G uid e October 2006 (Third Edition) Part Number 404314-003.
© Copyright 2006 Hewlett-Packard Development Company, L.P. The information contained herein is subject to chan ge without no tice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such produc ts and services.
Contents 3 Con te nt s Component iden tifica tion ............................................................................................................... 6 UPS fron t panel ......................................................................
Contents 4 UPS operates on battery only ................................................................................................... ................. 43 UPS frequently switches between utility and ba ttery power ...............................
Contents 5 Preventing electros tatic discharge ............................................................................................. ................. 57 Grounding methods to preven t electrostati c discha rge .................................
Component identification 6 C om ponent i den tif icati on In this section UPS fron t panel ................................................................................................................ ........................ 6 UPS front panel controls and LED in dicators .
Component identification 7 UP S fr ont panel co ntr ols and LED indi cato r s Item Description Function 1 Power On/Standby button Turns the UPS power on and off, an d places the UPS in Standby mode. 1 2 Power LED Green—The UPS is on and supplying connected equipment with AC power.
Component identification 8 Item Description Function 6 Battery Warning LED Red—During a self-test, the UPS found that the batteries must be recharged. Charge the batteries and repeat the self-test (" Initiating a self- test " on page 35 ).
Component identification 9 Item Description 13 ERM connector For information about controlling load segments re motely, see "Po wer management software (on page 37 ).
Component identification 10 REPO port The UPS includes an RJ-11 type EPO port. The EPO fu nction can be used to power down the UPS output receptacles in an emergency. This fe ature is enabled by utilizing a normally open (N.O.) switch (option 1) or a normally closed (N.
Component identification 11 To restore power to the load devi ces after the REPO feature is activated, press the Power On/Standby button after the AC source is reconnected to the UPS. IMPORTANT: Pressing and holding the Power On/Standby bu tton without utility present normally initiates a battery start and the UPS assumes the load.
Installation 12 Inst allati o n In this section Precautions .................................................................................................................... ........................ 12 Preparing to inst all the ha rdware ..........
Installation 13 Selecting a site WARNING: To prevent fire or electri c sh ock, install the unit in a temperature- and humidity-controlled indoor environmen t, free of conductive contaminants.
Installation 14 1. Remove the UPS front bezel. 2. Attach the logo badge above the LED/Control panel..
Installation 15 3. From inside the bezel, gently push out th e LED/Control panel and rotate 90 degrees. 4. Replace the front bezel..
Installation 16 5. Stand the unit on its side with the LED/Control panel at the top. Extend the tower stand to fit any configuration from 1U to 9U..
Installation 17.
Installation 18 6. Adjust the fine adjustment screws to ensure the tower stands fit securely around the UPS and/or ERM. Inst alling the UP S in a r ac k Before installing the unit, review and adhere to all warnings provided in "Precautions (on page 12 ).
Installation 19 1. Attach the 2U side-mounting brackets to t he unit. 2. Loosen the wing nuts, and extend the brackets to the desired length..
Installation 20 3. Insert screws through the rack into the mounting ra il and the front of each mounting bracket. Do not completely tighten the screws. 4. Insert screws through the rack into the mounting ra il and the rear of each mounting bracket. Do not completely tighten the screws.
Installation 21 Connecting the batteries WARNING: The unit contains sealed lead-aci d ba ttery modules. To prevent fire or chemical burns: • Do not attempt to recharge batteri es after removal fr om the unit. • Do not disassemble, crush, or puncture the batteries.
Installation 22 2. Connect the battery lead to the battery terminal. NOTE: A small amount of arcing may occur when conne cting the batteries. This is normal and does not damage the unit or present any safety concern. 3. Replace the UPS front bezel . 4.
Installation 23 CAUTION: Do not set the Battery Charge Level switch to the down position without an ERM connected. There is a risk of damaging the intern al battery system of the UPS. NOTE: DIP switch 4 is inactive and does not af fect UPS operation regardless of the position.
Installation 24 IMPORTANT: If using HPPM, connect the Management Serv er to an unswitched output receptacle (" UPS R/T2200 INTL rear panel " on page 9 , " UPS R/T2200 NA/JPN/TWN rear pa.
Installation 25 Connecting the USB communications port CAUTION: Using a USB to serial converter cable will damage the UPS. Connecting the REPO port WARNING: To meet the requirements state d in NE C (NFPA 70) Articles 645-10 and 645- 11, a UPS installed in a computer equipment room must be connected to a REPO circuit.
Installation 26 NOTE: Wire the connector block using stranded, nons hielded wire (AWG #22 - #18, or equivalent). Connecting the ground bonding cable The ground bonding screw is provided as an atta chment point for conductors.
Installation 27 • Connect the device power cords to the output receptacles on the rear panel of the UPS (NA/JPN/TWN model). -or- • Connect devices to the output receptacles on th e rear panel of the UPS using the jumper cords included with the UPS (INTL model).
Installation 28 1. Attach the logo badge above the LED/Control panel..
Installation 29 2. Stand the unit on its side with the LED/Control panel at the top. Extend the tower stand to fit any configuration from 1U to 9U..
Installation 30.
Installation 31 3. Adjust the fine adjustment screws to ensure the tower stands fit securely around the UPS and/or ERM. Inst alling the ERM in a r ack Before installing the unit, review and adhere to all warnings provided in "Precautions (on page 12 ).
Installation 32 1. Attach the 2U side-mounting brackets to t he unit. 2. Loosen the wing nuts, and extend the brackets to the desired length..
Installation 33 3. Insert screws through the rack into the mounting ra il and the front of each mounting bracket. Do not tighten. 4. Insert screws through the rack into the mounting ra il and the rear of each mounting bracket. Do not tighten. 5. Tighten the wing nuts.
Installation 34 This symbol indicates the presence of el ec tric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason. WARNING: To reduce the risk of injury from electric shock hazards, do not open this enclosure.
UPS operations 35 UP S oper atio ns In this section Initiating a self-test ......................................................................................................... ......................... 35 Silencing an au dible al arm ............
UPS operations 36 UPS provides sine wave power from the battery reserves for as long as the distorti on is present. In areas with poor utility power or where the UPS in put power comes from a backup generator, continuous waveform distortion causes the UPS to switch to batte ry power.
Power management 37 P o w er management In this section Power manageme nt software ....................................................................
Maintenance 38 Maintenance In this section Updating the UP S firm ware ...................................................................................................... ............... 38 Replacing th e batte ries ................................
Maintenance 39 Battery care and storage guidelines CAUTION: Because of the short shelf life of the batteri es, avoid storing a battery spare as a backup. Do not maintain an inventory of spare batteries on site un less a procedure to keep thes e batteries charged while in storage is implemented.
Maintenance 40 3. Disconnect the battery leads. 4. Remove the battery bracket. 5. Remove the UPS battery modules..
Maintenance 41 IMPORTANT: Do not pull the battery leads when removing or installing the batteries. To replace the component, reverse the r emoval procedure. IMPORTANT: Charge the batteries for at least 24 hours before supplying backup power to devices.
Troubleshooting 42 T r oubleshooting In this section UPS does no t start ............................................................................................................. ..................... 42 UPS does not communicate with the host compu ter .
Troubleshooting 43 2. Check the troubleshooting i nformation in this do cument to determine the cause of the alarm. C ir c uit br eak er tr ips Action: Remove some of the load, and then press the circuit breaker to reset the load. UP S oper ates o n batter y o nl y Action: 1.
Troubleshooting 44 If the Battery Charge LED is also red: a. Save your work, and power down the UPS (" Powering down the UPS " on page 36 ). b. After the blackout or brownout is over, power up the UPS (" Powering up the UPS " on page 27 ).
Specifications 45 Sp e c i fica t io ns In this section UPS physical sp ecifications.................................................................................................... .................. 45 ERM physical sp ecifications ...............
Specifications 46 UP S output spec if i cati ons UPS model Output receptacles Maximum current R/T2200 NA/JPN/TWN 4 x NEMA 5-15R, 4 x NEMA 5- 15/20R 18.
Specifications 47 Battery spec if i cati o ns Feature Specification Type 12 V, 9 AH, sealed, maintenance- free, rechar geable, lead-acid battery Voltage The battery modules have a battery string voltage of 48 V. Charging Complete charge takes no more than 24 hours.
Spares 48 S par e s In this section Ordering spar es ................................................................................................................ ..................... 48 Spare parts list ...........................................
Technical support 49 T ec hni cal su ppo r t In this section Before you contact HP.......................................................................................................... ................... 49 HP contact in formation ...............
Warranty information 50 W a rran t y i n fo rm at io n In this section Limited wa rranty ............................................................................................................... ..................... 50 $250,000 Computer Load Pr otection Gu arantee .
Warranty information 51 • Notification from power management software.
Regulatory compliance notices 52 R e gulatory com pli ance noti ces In this section Regulatory compliance id entification nu mbers ................................................................................... ........ 52 Federal Communications Commissio n notic e .
Regulatory compliance notices 53 Class A equipment This equipment has been tested and found to comply wi th the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are design ed to provide rea sonable protection against harmful interference when the equipment is operated in a commercial environment.
Regulatory compliance notices 54 Modif i cati ons The FCC requires the user t o be notified that any ch anges or modifications made to this device that are not expressly approved by Hewlett-Packard Company may void the user’s authority to operate the equipment.
Regulatory compliance notices 55 Dispo s al of w as te eq uipme nt b y use r s in pr i v ate hou seho lds in the E ur opean U ni on This symbol on the product or on its packagi ng indicates that this product must not be disposed of with your other household waste.
Regulatory compliance notices 56 K or ean no ti ce Class A equipment Class B equipment Bat ter y r eplacement not i ce WARNING: Power products contain sealed lead- acid battery modules. A risk of fire and burns exists if the battery is not properly handled.
Electrostatic discharge 57 Elec tr o stati c disc har ge In this section Preventing electros tatic discharge ............................................................................................. ................ 57 Grounding methods to preven t electrostati c discharge .
Acronyms and abbreviations 58 A c r on y ms and a bbr e v i ations EPO emergency power off ERM extended runtime module HPPM Hewlett-Packard Power Manager IEC International Electrotechnical Commission .
Index 59 A alarm conditions 35 alarms, silencing 35 authorized reseller 49 B backup time, insufficient 43 batteries, care and storage 39 batteries, charging 27, 34 batteries, cleaning spills 41 batter.
Index 60 installing the UPS 13 insufficient backup time 43 International model 9 J Japanese notice 55 K Korean notices 56 L LED, power button 7 LEDs 6, 7 LEDs, troubleshooting 42 limited warranty 50 l.
Index 61 U Uninterruptible Power System, high-voltage models 9 Uninterruptible Power System , low-voltage models 8 UPS does not start 42 UPS operations 35 UPS, installing 12, 13 USB connectors 25 V Vo.
デバイスHP (Hewlett-Packard) R2200の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) R2200をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) R2200の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) R2200の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) R2200で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) R2200を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) R2200の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) R2200に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) R2200デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。