HP (Hewlett-Packard)メーカーZ7634-96002の使用説明書/サービス説明書
ページ先へ移動 of 30
Addendum to D Class Enterprise Servers Installa tion and User’s Gui de Third Edition HP 9000 Series 800t Computers Manufacturing P art Number: Z7634-96002 F ebruary 2000 Communications Infrastructur.
2 Notice The information contai ned in this document is subject to change without notice . HEWLETT -P ACKARD MAKES NO W ARRANTY OF ANY KIND WITH REGARD TO THE MATERIAL, INCLUDING , BUT NOT LIMITED T O THE IMPLIED W ARRANTIES OF M ERCHANTABILITY AND FITNESS FOR A P ARTICULAR PURPOSE.
Printing History The Printing History belo w identifies the edit ion of this manual and any updates that a re included. P eriodically , update pa ckages are dis tributed whic h cont ain re place ment p ages to b e merg ed int o the manu al, including an updated cop y of this prin ting his tory page.
4 About This M anual The HP 900 0 family of p roducts embraces the D Cl ass Enterprise Server line which incl udes Series 800t, a NEBS-compatibl e version. This document exp lains how to insta ll the seismic rack and DC power supply which provide NEBS compatibility for the syst em.
Contents 5 1. Addendum to D Class E nterprise Servers System Installation Guide C o n t e n t s ..... ...... .......... ...... ....... ......... ....... .. 8 P u r p o s eo ft h i sA d d e n d u m ......... ...... ....... ...... ......... 9 T o o l sN e e d e d .
6 Contents.
7 1 Addendum to D Class Enterprise Servers S ystem Installation Guide.
8 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide Contents Contents • Purpose of thi s Addendum •S e i s m i c R a c k K i t • Installa tion • DC P ower Su.
Chapter 1 9 Addendu m to D Cl ass Ent er pr ise S er vers System I nstall ation Gu ide Purpose of t his Addendum Purpose of this Addendu m This ad dendum pr ovides i nformat ion and pr ocedur es for in stallat ion of a Hewlett- P ackard 9000 S eries 80 0t D Clas s Server in a Central Of fice.
10 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide Seismic Rack Kit Seismic Rack Kit The HP 900 0 Serie s 800t D Cla ss Serv er can be fi tted wit h a seismic ra ck mount kit f or inst allation in a 19-inch open rel ay rack.
Chapter 1 11 Addendu m to D Cl ass Ent er pr ise S er vers System I nstall ation Gu ide Seismic Ra ck Kit Split L ock W ash er , #12 10 17 2190-0 631 Flat W asher , #12 10 18 3050-01 03 Screw 10-32 x,.
12 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide Seismic Rack Kit Site Hazard Considerations Hewlett P ackard recommends the following environment al and mechanical factors for review and compliance prior to installation of equ ipmen t.
Chapter 1 13 Addendu m to D Cl ass Ent er pr ise S er vers System I nstall ation Gu ide Installation Installation Install t he seis mic rack kit a nd the HP 9000 S eries 800 t D Clas s Server into a n open relay r ack using t he follo wing step s.
14 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide Installat ion F igure 1-1 Seismic Rack Installat ion 5. Attach th e right and left main bracket pa nels (items 2 , 3 in Figure 1-2 on page 15) to the v ertical mount ing rails of the r elay rack, using hardware item 24, T able 1-1 on page 10.
Chapter 1 15 Addendu m to D Cl ass Ent er pr ise S er vers System I nstall ation Gu ide Installation 7. Asse mble base pan (Fig ure 1-2, item 7) to lower row of hole s on main brackets, but do not tigh ten the hard ware yet. With pan posi tioned between t he main bracket pa nels from the re ar , raise it to alig n the holes as n eeded.
16 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide Installat ion 8. Usi ng item 16 sc rews (o nly) at tac h the bez el mou nt brac kets (item s 5, 6 in Fig ure 1-3) to the vert ical rails as s hown. Attac h the two clip-on rec eptac les ( item 3 0) at th e bott om of th e bra ckets a s shown .
Chapter 1 17 Addendu m to D Cl ass Ent er pr ise S er vers System I nstall ation Gu ide Installation 12. Attach cable retractor (item 26, Figure 1-3) t o right main bracket as show n. 13. Attach the s lide ass emblies to the main brackets using the top ro w of holes (above t he base pan).
18 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide Installat ion F igure 1-4 Seismic Rack Installat ion W ARNING The HP 9000 D Class Ente rprise Server weighs about 49.5 kg (110 lbs ).Use Two people to l ift the D Class s erver cabinet .
Chapter 1 19 Addendu m to D Cl ass Ent er pr ise S er vers System I nstall ation Gu ide Installation 18. Attach the lat ch panel (item 4 ) to front of mount ing tray using fiv e screws . 19. With the computer s ecurely en gaged wit hin the rack as sembly , check alignmen t of top cover (refe r to Step 10) and t ighten all fa steners.
20 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide Installat ion 23. Secure t he bezel to the beze l mounts w ith th e cover pla tes (item 10, 2 places) shown in Fig ure 1-6. F igure 1-6 Seismic Rack Installat ion 24.
Chapter 1 21 Addendu m to D Cl ass Ent er pr ise S er vers System I nstall ation Gu ide DC P ower Suppl y DC P ower Supply The HP 9000 Serie s 800t D Class Se rver contai ns a NEBS-compati ble direct current (D C) power supply , rather than the alternating curre nt (AC) power suppl y furnished with the standard HP 9000 D Class computer .
22 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide DC P ower Supply T able 1-2 shows t he pinouts for the site end of this ca ble. Figure 1-5 shows a dia gram of the pins . The user /installer must make connect ions to the site i nstallation u sing this informa tion.
Chapter 1 23 Addendu m to D Cl ass Ent er pr ise S er vers System I nstall ation Gu ide DC P ower Suppl y NO TE T o protect t he equipment from overloa d or short circuits that may cause equi pment d amage or fire, the po wer supp ly is fuse d inter nal ly .
24 Chapter 1 Adden dum to D C lass E nter pr ise S er vers Sys tem Instal latio n Guide DC P ower Supply Specifications Repla cement P ower Supply T o order a replacemen t DC Po wer Supply , order re placement part number Z 7634-670 03.
25 A Regulatory/Safety Stat ements.
26 Appendix A Regulator y/Safety Statements FCC S tate men t (U SA Only ) FCC S ta teme nt ( USA Onl y) The F e deral Communi cations Co mmission (in 47 CF R 15.105 ) has specified t hat the following noti ce be brought to the at tention of the users of this pr odu ct.
Appendix A 27 Regu lator y/Sa f ety Sta tements International Internat ional VCCI Class A Statement (Japan Only) Spécification A TI Classe A (France seulement) DECLARATION D'INST ALLATION ET DE .
28 Appendix A Regulator y/Safety Statements International Arrêté du 27 Mars 19 93, publié au J .O. du 28 Mars - ATI Product Noise Declaration ( Germany Only) Acoustic Noise Emissions LpA: 57 d B At bys tand er pos ition pe r ISO 77 79.
Appendix A 29 Regu lator y/Sa f ety Sta tements EMC Reg ulatory EMC Regulatory EMC Certification prEN 55024 -2 prEN 55024 -3 prEN 55024 -4 F or USA, FCC Class A, part 1 5 Fo r E u r o p e, C I S P R -.
30 Appendix A Regulator y/Safety Statements EMC Regulatory DECLARA TION OF CONFORMITY according to I SO/IEC G uide 22 and E N 45104 Manufac turer’s Name: Hewlett-Packard Company Manufac turer’s Addr ess: 8000 Footh ills Blvd.
デバイスHP (Hewlett-Packard) Z7634-96002の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
HP (Hewlett-Packard) Z7634-96002をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHP (Hewlett-Packard) Z7634-96002の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。HP (Hewlett-Packard) Z7634-96002の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。HP (Hewlett-Packard) Z7634-96002で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
HP (Hewlett-Packard) Z7634-96002を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHP (Hewlett-Packard) Z7634-96002の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、HP (Hewlett-Packard) Z7634-96002に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHP (Hewlett-Packard) Z7634-96002デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。