OwnerÕ s Manual 42999/44050 SINCE 1 8 8 6 ®.
Other Quality Pr oducts from Hunter Fans Air Purifiers Humidifiers.
Installation Operation T able Of Contents Features 6 Remove Old Thermostat 8 Labeling Wires 10 Connecting Wires and Mounting Thermostat 14 System Selector Switches 14 Start-Up 16 Reviewing Current T e.
Read This Befor e Installing Thermostat IMPORT ANT 1 Read the entire installation section of this Owner’ s Manual thoroughly before you begin to install or operate your Hunter Thermostat. • Remove the mylar label from the display window . INST ALLA TION 2 All installation is normally performed at your thermostat.
TEMPERA TURE RANGE 6 Y our thermostat can be programmed between 40°F and 95°F (5°C and 35°C). However , it will display room temperatur es from 32°F to 99°F (0°C to 37°C). POWER F AILURE 7 Whenever the main power is interrupted or fails, the battery power retains the pr ograms and current time.
FIL TER HEA T OFF COOL AUTO FA N RESET Featur es (Model 42999) ■ Function Switch For turning on heating and cooling system. ■ Fan ON and AUTO Selector Switch.
Featur es (Model 44050) ■ Function Switch For turning on heating and cooling system. ■ Fan ON and AUTO Selector Switch. ■ Reset Button For resetting thermostat.
8-9 Installation This thermostat comes with two #8 slotted screws and two wall anchors for mounting. T o install your unit, you should have the following tools and materials. ■ Slotted screwdriver ■ Electric drill and 3/16" bit ■ Hammer ■ T wo 1.
W all Mounting Plate Thermostat Cover W all Mounting Plate Thermostat Cover TYPICAL HOME THERMOST A TS FIGURE 1.
10-11 Installation ■ Each wire coming fr om the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in T able A on page 9.
Wir e Labeling RH G Y W RC RH RH RC RC G G Y Y W W and connect to thermostat T erminal shown then mark wire with label shown If the code letter on your existing thermostat is RH, R, VR or 4 24 V olt G.
12-13 Installation NOTE: If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and RC terminals. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals.
Snap open the wallplate from your thermostat by pr essing the release tab on the bottom of the thermostat. Position wallplate on wall and pull existing wires thr ough large opening. Then level for appearance. Mark holes for plastic anchors provided if existing holes do not line up with Hunter Thermostat holes.
14-15 Installation Connect Wir es and Mount Thermostat Cover to W all Plate Selector Switches The heating system selector and the F°/C° selector switches are located on the Printed Circuit Boar d. ■ Heating system selector The heating system selector is a switch on the Printed Circuit Boar d on the inside of the thermostat.
FIGURE 3 FIGURE 4 ■ Be sure to tighten the terminal scr ews securely , otherwise a loose wire could cause operational problems with your system or thermostat. ■ Push excess wire back into hole to pr event interference with mounting of the thermostat cover .
Pr ogramming ■ 68° indicates the current setting of the thermostat. ■ If pressed for mor e than 2 seconds, you will adjust the set- ting as explained below . 68 F TEMP SET TEMP FIL TER LO BA T HOLD HEA T COOL ■ 69° is current r oom temperature.
In this example we are raising the curr ent set temperature of 68°F to a new setting of 72°F . Setting New T emperatur e ■ Press arr ow to display current temperature setting.
Operations 72 . 7I . 70 . The Hunter Digital Thermostat measures and stor es the amount of time the heating or air conditioning system operated. After 500 hours of usage, the word “FIL TER” will appear and flash on the display , reminding you to check or replace your system filter .
Note: Filter button works only when “FIL TER” is displayed on the display . If Filter button is pressed when “FIL TER” is not displayed, the inter nal counter will not reset. Y our thermostat is pre-programmed at the factory to cycle when the temperature rises 1° above or 1° below the temperatur e setting.
T roubleshooting Pr oblem Solution SCRAMBLED OR DOUBLE DISPLA Y (numbers over numbers NO DISPLA Y ENTIRE DISPLA Y DIMS AUTO/F AN DOES NOT COME ON HEA TING OR COOLING DOES NOT GO ON OR OFF 1. Remove clear mylar sticker . 1. Check battery connections and batteries.
ERRA TIC DISPLA Y IF UNIT CONTINUES TO OPERA TE IN OFF POSITION THERMOST A T READS , HI, LO PERMANENTL Y 1. Pr ess the reset button once with a small pin and hold in for two seconds.
Wiring Diagrams 22-23 4-wire Heat/Cool System 5-wire Heat/Cool System THERMOST A T G W Y RH RC Heat Relay or V alve Heat /Cool T ransformer Fan Relay Cool Contactor Jumper THERMOST A T G W Y RH RC Hea.
2-wire Heat Only 3-wire Cool Only 3-wire Heat Only THERMOST A T G W Y RH RC Heat Relay or V alve Heat T ransformer THERMOST A T G W Y RH RC Heat Relay or V alve Heat T ransformer Fan Relay THERMOST A .
デバイスHunter 42999 44050Sの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hunter 42999 44050Sをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHunter 42999 44050Sの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hunter 42999 44050Sの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hunter 42999 44050Sで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hunter 42999 44050Sを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHunter 42999 44050Sの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hunter 42999 44050Sに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHunter 42999 44050Sデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。