T ype 2 Models T ype 2 Models T ype 2 Models Form# 42666-01 20081029 ©2008 Hunter Fan Co. For Y our Records and W arranty Assistance For reference, also attach your receipt or a copy of your receipt to the manual. __________________________________________ Model Name __________________________________________ Model No.
2 42666-01 • 10/29/08 • Hunte r Fan Company © 2008 Hunter Fan Company Y our new Hunter ® ceiling fan is an addition t o your home or oce that will provide comfort and performance for many years. is installat ion and operation manual gives you complete inst ructions for installing and operating your fan.
3 42666-01 • 10/29/08 • Hunte r Fan Company Ins t aller ’ s Choic e and O ptional Ac ce ssorie s Understan ding Mountin g and Instal ler’ s C hoic e ® Hunte r ’ s patent ed 3-p osition mounting syst em provides you maximum installation exibility and ease .
4 42666-01 • 10/29/08 • Hunte r Fan Company T o install a ceiling fan, be sure you can do the following: • Locate the ceiling jois t or other suitable supp ort in ceiling . • Drill holes for and install woo d s crews. • Identify and conne ct elec trical wires.
5 42666-01 • 10/29/08 • Hunte r Fan Company CAU TION: T o avoid possible ele ctrical shock , b efore installing your fan, disconnect the p ower by turning o t he circuit br eakers t o the outlet box and asso ciated wall switc h loc ation.
6 42666-01 • 10/29/08 • Hunte r Fan Company W A RNING: Fan m ay fall if not ass embled as directed in thes e installation ins tructions. 3-1. Unbundle the wires from t he fan. For Standard or Angle d mounting: 3-2. Insert the downrod through the canopy and canopy trim ring .
7 42666-01 • 10/29/08 • Hunte r Fan Company fsdfs df All wiring must b e in accorda nce with national and lo ca l elec trica l code s and ANSI/NFP A 70. If you are unfamiliar with wirin g , use a qualifie d elec trician . W all swit ches are not included.
8 42666-01 • 10/29/08 • Hunte r Fan Company W A RNING: Failur e to complete t he following steps could cause the fan to fall. No te: It is recommended you use a magnetic tip screwdriver for the following steps. 5-1. Rotate the hange r ball so the tab in the cano py is secure in the hanger ball gr oove .
9 42666-01 • 10/29/08 • Hunte r Fan Company 9 Our exclusive Easy Lock ™ blad e assembly enables you to lock the blades in place without tools and to r emove the blades easily for cleaning . 6-1. Op en the locking mechanism. 6-2. Align the holes in the blade with the blade iron.
10 42666-01 • 10/29/08 • Hunte r Fan Company Y our Hunter fan comes with an int egrated light xt ure assembly and an optional swit ch housing cap and plug b utton. i s feat ure gives you the option of installing the fan with OR without t he included light xtur e.
11 42666-01 • 10/29/08 • Hunte r Fan Company Lower Swit ch Housing Housing Ass embly Screw Plug Connector Detail 7-1. T o attach the lower swit ch housing , connec t the upper plug connector from the motor to t he lower plug connec tor in the lower switc h housing as sembly .
12 42666-01 • 10/29/08 • Hunte r Fan Company 7 • Completin g Y o ur Install ation With or Without a Bow l Lig ht Fixture ( C ontinue d) Installing the Gl ass Bowl 7-3. First install included 14W CFL bulbs into the sockets. 7-4. If the fandangle is attached to the extra pull ch ain, remove it now .
13 42666-01 • 10/29/08 • Hunte r Fan Company 7 • Completin g Y o ur Install ation With or Without a Bow l Lig ht Fixture ( C ontinue d) Uninstalling the Lig ht Fixture 7-12. T o uninstall the light xt ure, rst di sconnec t the plug connec tors betw een the black wire and t he red wire.
14 42666-01 • 10/29/08 • Hunte r Fan Company In warm weather , us e downward air ow patt ern In cold weather , us e upward air ow pattern 8-1. T urn on elec trical power to the fan. 8-2. e fan pull chain contr ols power to the fan. e pull chain has four settings in se quence: High, Medium, Low and O.
15 42666-01 • 10/29/08 • Hunte r Fan Company Problem: No thing happens ; fan do es no t move. 1. T urn power on, replace fuse , or reset break er . 2. Lo os en canopy , check all connections accor ding to the wiring the fan se ction. 3. Check the plug conne ction in the switc h housing .
デバイスHunter Fan 42666-01の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hunter Fan 42666-01をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHunter Fan 42666-01の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hunter Fan 42666-01の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hunter Fan 42666-01で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hunter Fan 42666-01を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHunter Fan 42666-01の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hunter Fan 42666-01に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHunter Fan 42666-01デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。