Hunter Fanメーカー44300の使用説明書/サービス説明書
ページ先へ移動 of 35
OwnerÕ s Manual SINCE 1 8 8 6 ® 44300/44350.
Other Quality Pr oducts fr om Hunter Fans Humidifiers Air Purifiers.
W e ar e pleased you have selected one of our broad line of home comfort pr oducts. Our products ar e manufactured to high quality standar ds and are designed for years of service. W e hope you will be satisfied and thank you for buying a Hunter pr oduct.
Read This Befor e Installing Thermostat IMPORT ANT 1 Read the entire installation section of this Owner’ s Manual thoroughly before you begin to install or operate your Hunter Thermostat. • Remove the mylar label from the display window . INST ALLA TION 2 All installation is normally performed at your thermostat.
This thermostat is designed to optimize the use of your heating and cooling equipment. It does this by matching your comfort (the temperatures in your home) to your schedule. An example: 6:00 am – Y ou wake up. Program 1 has the heat set to 70° (21°C).
LIGHT 6-7 Featur es Manual switch for turning on heating and cooling system. Display backlight for viewing in the dark. (Feature found only on certain models.
Changes the clock into 12 or 24 hour (military) mode. (Model 44300) HOLD/CLEAR button. (Model 44350) For entering minute of day . For reviewing and changing weekday or weekend programs Picks the day/days for programs Returns display to current time and temperature.
This thermostat comes with two #8 slotted screws and two wall anchors for mounting. T o install your unit, you should have the following tools and materials.
TYPICAL HOME THERMOST A TS FIGURE 1 W all Mounting Plate Thermostat Cover W all Mounting Plate Thermostat Cover.
■ Each wire coming fr om the wall to the existing thermostat is connected to a terminal point on that thermostat. Each of these terminal points is usually marked with a code letter as shown in T able A on page 11. ■ The number of wires in your system can be as few as two (for heat only systems), as many as eight, or any number in between.
Wir e Labeling RH G Y W RC RH RH RC RC G G Y Y W W and connect to thermostat T erminal shown then mark wire with label shown If the code letter on your existing thermostat is RH, R, VR or 4 24 V olt G.
12-13 Installation NOTE: I f your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and RC terminals. Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH and RC terminals.
Snap open the wallplate from your thermostat by pr essing the release tab on the bottom of the thermostat. Position wallplate on wall and pull existing wires thr ough large opening. Then level for appearance. Mark holes for plastic anchors provided if existing holes do not line up with Hunter Thermostat holes.
The heating system selector and the F°/C° selector switches are located on the Printed Circuit Boar d. ■ Heating system selector The heating system selector is a switch on the Printed Circuit Boar d on the inside of the thermostat. The switch is at “HG” position.
■ Be sure to tighten the terminal scr ews securely , otherwise a loose wire could cause operational problems with your system or thermostat. ■ Push excess wire back into hole to pr event interference with mounting of the thermostat cover . ■ Make sure the Function Switch is set at OFF , and the F AN-AUTO Switch is in AUTO.
Pr ogramming 1 Remove mylar label covering display window . 2 When the heating or cooling system is actually operating, “HEA T” or “COOL” will appear on the display . 3 If power is interrupted the batteries will keep all programs. 4 If “LOW BA TT” indicator appears on the display replace the batteries.
■ Press and hold until curr ent hour appears on display . ■ Press and hold until curr ent minutes appear on display . ■ Press until curr ent day appears on display . ■ Returns to normal time and temperature. ■ If return is not pressed it will r eturn automatically in 10 seconds.
Pr ogramming Studies conducted by the Department of Ener gy estimate that setting your thermostat back 10°F for two 8-hour periods during winter can reduce your fuel bill by as much as 33%. By setting your thermostat up 5° for two 8-hour periods during summer you can reduce your fuel bill up to 25%.
NOTE: The thermostat program will NOT take effect immediately after programming of your thermostat but at the next programmed time/temperature change. The thermostat is preset to 68°F for heat and 78°F for air conditioning.
Pr ogramming Before pr ogramming or changing the program, use this Personal Pr ogram Schedule to determine which times and temperature settings will best satisfy both your comfort and ener gy saving requirements. Use a pencil so you can revise your r ecords each time you change your temperature settings.
Y our thermostat can be programmed in two differ ent ways. 1. Auto-program method 2. Manual method Before pr ogramming, position the HEA T/OFF/COOL selector to the mode to be programmed. Auto-program method In auto-program method, you can pr ogram your thermostat instantly for the entire week by simply pressing “Auto Pr og.
Pr ogramming W eekday Pr ograms ■ Normal display of time, temper - ature, and day of the week. ■ Selects days M to F for same set of 4 programs each day .
■ Press once to change temperature to 69°F . ■ W eekday program 1 is complete. ■ Press PROG to move to program 2, 3, and 4 and follow the same steps M T W TH F SA SU SET TEMP HOLD TEMP 8 6 : 00 69 c AM PM HEAT COOL 1 234 FILTER LO BAT Use to insert or change time and temperatures of other pr ograms.
Pr ogramming ■ SA and SU will have same program. M T W TH F SA SU SET TEMP HOLD TEMP 83 : 00 68 c AM PM 1234 FILTER LO BAT HEAT COOL ■ M is selected, program for M only . M T W TH F SA SU SET TEMP HOLD TEMP 80 : 00 68 c AM PM 1234 FILTER LO BAT HEAT COOL 24-25 ■ M to F are selected.
■ T is selected. M T W TH F SA SU SET TEMP HOLD TEMP 80 : 00 68 c AM PM 1234 FILTER LO BAT PROG DA Y HEAT COOL ■ W is selected. M T W TH F SA SU SET TEMP HOLD TEMP 80 : 00 68 c AM PM 1234 FILTER L.
Pr ogramming W eekday Pr ogram ■ Normal display of current time, temperature, and day of week. ■ 1st weekday program is displayed. ■ Program indicator (1) appears.
T o Review The Curr ent T emperature Setting: Press for 2 seconds or less: or ■ Current time and temperatur e M T W TH F SA SU SET TEMP HOLD TEMP 8 9 : 15 68 c AM PM HEAT COOL 1 2 34 FILTER LO BAT ■ 70 indicates the current setting of the thermostat is 70°F .
Pr ogramming ■ Press arr ow to display current set and room temperatur es. M T W TH F SA SU 89 : 68 60 c AM PM HEAT COOL 1 2 34 FILTER LO BAT M T W TH F SA SU SET TEMP HOLD TEMP 89 : 70 60 c AM PM H.
In the event you wish to hold your manual override for vacation or just an extended period of time, follow the temporary manual override instructions on page 28, then immediately press HOLD/CLEAR. This will maintain override setting indefinitely . “HOLD” will appear on the display .
Other Featur es Y our thermostat is pre-pr ogrammed at the factory to cycle when the temperature rises 1° above or 1° below the temperature setting. It cannot be changed. T emperatur e Span The 12/24 hour switch is located on the printed circuit boar d inside the thermostat.
Operations 72 . 7I . 70 . Y our thermostat also keeps a recor d of the number of hours your filter has been in use. T o maximize energy ef ficienty , change or clean your filter regularly .
T roubleshooting Pr oblem Solution SCRAMBLED OR DOUBLE DISPLA Y (numbers over numbers NO DISPLA Y ENTIRE DISPLA Y DIMS PROGRAM DOES NOT CHANGE A T YOUR DESIRED SETTING AUTO/F AN DOES NOT COME ON 1. Remove clear mylar sticker . 1. Check battery connections and batteries.
HEA TING OR COOLING DOES NOT GO ON OR OFF ERRA TIC DISPLA Y IF UNIT CONTINUES TO OPERA TE IN OFF POSITION THERMOST A T READS , HI, LO PERMANENTL Y 1. Check that function switch is in corr ect position (“HEA T” or “COOL”). 2. Ther e may be as much as 20 seconds delay before the system turns on - wait and check.
34-35 Wiring Diagrams 4-wire Heat/Cool System 5-wire Heat/Cool System THERMOST A T G W Y RH RC Heat Relay or V alve Heat /Cool T ransformer Fan Relay Cool Contactor Jumper THERMOST A T G W Y RH RC Hea.
2-wire Heat Only 3-wire Cool Only 3-wire Heat Only THERMOST A T G W Y RH RC Heat Relay or V alve Heat T ransformer THERMOST A T G W Y RH RC Heat Relay or V alve Heat T ransformer Fan Relay THERMOST A .
デバイスHunter Fan 44300の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Hunter Fan 44300をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはHunter Fan 44300の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Hunter Fan 44300の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Hunter Fan 44300で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Hunter Fan 44300を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はHunter Fan 44300の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Hunter Fan 44300に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちHunter Fan 44300デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。