IBMメーカーRemote Supervisor Adapter IIの使用説明書/サービス説明書
ページ先へ移動 of 132
Rem ot e Su p e rvis o r Ad a p t e r II SlimLin e an d Re mo t e S u pe rvis o r Ad a p t e r II Us er ’ s Gu i d e .
.
Rem ot e Su p e rvis o r Ad a p t e r II SlimLin e an d Re mo t e S u pe rvis o r Ad a p t e r II Us er ’ s Gu i d e .
Note: Before using this information and the product it supports, read the general information in Appendix B, “Notices,” on page 1 15. Seventh Edition (April 2007) © Copyright International Business Machines Corporation 2003, 2007. All rights reserved.
Contents Chapter 1. Introduction . . . . . . . . . . . . . . . . . . . . . .1 Remote Supervisor Adapter II features . . . . . . . . . . . . . . . .1 Web browser and operating-system requirements . . . . . . . . . . . .3 Notices used in this book . . .
Using the configuration file . . . . . . . . . . . . . . . . . . . .6 4 Backing up your current configuration . . . . . . . . . . . . . . .6 4 Restoring and modifying your ASM configuration . . . . . . . . . . .6 5 Restoring ASM defaults . . . . . . .
srcfg command . . . . . . . . . . . . . . . . . . . . . . . 104 ssl command . . . . . . . . . . . . . . . . . . . . . . . . 105 tcpcmdmode command . . . . . . . . . . . . . . . . . . . . 106 timeouts command . . . . . . . . . . . . . . . . . . . . . .
vi Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User ’s Guide.
Chapter 1. Introduction This document explains how to use the functions of the IBM ® Remote Supervisor Adapter II SlimLine and the IBM Remote Supervisor Adapter II when they are installed in an IBM server .
v Alphanumeric or numeric pager alerts (not supported with the Remote Supervisor Adapter II SlimLine) v Automatic notification and alerts v Automated Server Restart (ASR) v Continuous health monitorin.
We b browser and operating-system requirements The Remote Supervisor Adapter II Web interface requires the Java ™ Plug-in 1.4 or later and one of the following Web browsers: v Microsoft ® Internet Explorer version 5.5 or later with the latest Service Pack v Netscape Navigator version 7.
4 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User ’s Guide.
Chapter 2. Opening and using the We b interface To access the Remote Supervisor Adapter II remotely using the Remote Supervisor Adapter II Web interface, you must log in to the adapter . This chapter describes the login procedures and describes the actions you can perform from the Remote Supervisor Adapter II Web interface.
3. Depending on how your system administrator has configured the user ID, the following window might open. 4. The Welcome window opens. Select a timeout value from the drop-down list in the field that is provided.
5. Click Continue to start the session. The browser opens the System Status page, which gives you a quick view of the server status and the server health summary .
Remote Supervisor Adapter II action descriptions T able 1 lists the actions that are available when you are logged in to the Remote Supervisor Adapter II.
T able 1. Remote Supervisor Adapter II actions (continued) Link Action Description Access Remote ASM 2 Access other service processors on the ASM interconnect network From the Access Remote ASM page, you can view a list of service processors that are present on the ASM interconnect network and establish a connection to any of those systems.
T able 1. Remote Supervisor Adapter II actions (continued) Link Action Description Security Configure the Secure Sockets Layer (SSL) Yo u can enable or disable SSL and manage the SSL certificates that are used. Yo u can also enable or disable whether an SSL connection is used to connect to an LDAP server .
Chapter 3. Configuring the Remote Supervisor Adapter II Use the links under ASM Control in the navigation pane to configure the Remote Supervisor Adapter II.
– TCP command mode protocol – Service location protocol v From the Security page, you can install and configure the Secure Sockets Layer (SSL) settings. v From the Configuration File page, you can back up, modify , and restore the configuration of the Remote Supervisor Adapter II.
field can contain up to 63 characters. To minimize confusion, set the ASM Name field to the nonqualified portion of the IP host name. The nonqualified IP host name consists of up to the first period of a fully qualified IP host name. For example, for the fully qualified IP host name asmcard1.
v Nonmaskable interrupt 3. Enable the server timeouts that correspond to the events that you want the Remote Supervisor Adapter II to respond to automatically . POST watchdog Use the POST watchdog field to specify the number of minutes that the Remote Supervisor Adapter II will wait for the server to complete a power-on self-test (POST).
POST and the starting of the operating system. If this interval is exceeded, the Remote Supervisor Adapter II generates a loader timeout alert and automatically restarts the server .
To disable the automatic server restart after a nonmaskable interrupt, select Disabled . 4. Scroll to the bottom of the page and click Save . Setting the date and time The Remote Supervisor Adapter II contains its own real-time clock to time stamp all events that are logged in the event log.
Synchronizing clocks in a network The Network T ime Protocol (NTP) provides a way to synchronize clocks throughout a computer network, enabling any NTP client to obtain the correct time from an NTP server .
Disabling the USB device driver interface If you want to prevent any application that is running on the server from requesting the Remote Supervisor Adapter II to perform tasks, you must disable the USB device driver interface. To disable the USB device driver interface, complete the following steps.
Note: By default, the Remote Supervisor Adapter II is configured with one login profile that enables remote access using a login user ID of USERID and a password of PASSW0RD (the 0 is a zero, not the letter O). To avoid a potential security exposure, change this default login profile during the initial setup of the Remote Supervisor Adapter II.
Note: This login ID is used to grant remote access to the Remote Supervisor Adapter II. 5. In the Password field, assign a password to the login ID. A password must contain at least five characters, one of which must be a nonalphabetic character . Null or empty passwords are accepted.
1. Log in to the Remote Supervisor Adapter II for which you want to set the global login settings. For more information, see Chapter 2, “Opening and using the Web interface,” on page 5. 2. In the navigation pane, click Login Profiles . 3. Scroll down to the Global Login Settings area.
Yo u can view and change the account security management configuration on the Custom Security Settings page. When you change the User login password required setting, you must also have a password, to be consistent with the requirement. User login password required Use this field to indicate whether a login ID with no password is allowed.
2. Yo u cannot distinguish between the alerts that are sent to remote alert recipients. All configured recipients receive each alert that you select. Configuring remote alert recipients Notes: 1.
4. To have only critical alerts sent to the recipient, select the Receives critical alerts only check box. 5. In the Status field, click Enabled to activate the remote alert recipient. 6. In the Name field, type the name of the recipient or other identifier .
For example, to log in to the IBM Global Network ® , the PPP login ID is in the following format: secureip. y. z where y is your account name and z is your user ID. 11 . In the PPP password field, type the password that is used to log in to the ISP .
To verify whether the selected Remote Supervisor Adapter II is the gateway to the interconnect network, complete the following steps: 1. Log in to the Remote Supervisor Adapter II for which you want to see the alert forwarding status. For more information, see Chapter 2, “Opening and using the Web interface,” on page 5.
Remote alert retry limit Use the Remote alert retry limit field to specify the number of additional times that the Remote Supervisor Adapter II will attempt to send an alert to a recipient.
T able 2. Critical remote alerts Alphanumeric pager code Alphanumeric recovery code Event Action 00 50 T emperature irregularity Generates an alert if any of the monitored temperatures are outside critical threshold values. To view the threshold values, click the temperature readings on the System Health page.
System alerts System alerts are generated for events that occur as a result of system errors. If the Select all system alerts check box is selected, an alert can be sent for any system alert. Notes: a. The Select all system alerts check box is not available on all servers.
1. Log in to the Remote Supervisor Adapter II where you want to set local events. For more information, see Chapter 2, “Opening and using the Web interface,” on page 5. 2. In the navigation pane, click Alerts and scroll down to the Monitored Local Events area.
2. In the navigation pane, click Serial Port . A page similar to the one in the following illustration is displayed. 3. In the Port function field, select the function for which this serial port will be used.
Set these values only if the alert forwarding functions are not working properly . Each string that is marked with an asterisk (*) must have a carriage return (^M) manually entered at the end of the field value. The following table describes the initialization strings for this modem.
T able 6. Port 1 settings (continued) Field What you type Escape guard (0 - 250) T ype the length of idle time that is used before and after the escape string is issued to the modem, so that the modem will recognize the escape string. This value is measured in 10-millisecond intervals.
v Yo u update the Remote Supervisor Adapter II firmware. For information about obtaining Remote Supervisor Adapter II firmware and software, see the Installation Guide . v Y our operating system has serial support for text management in the operating system.
b. Configure the Baud rate , Parity , and Stop bits fields to match the serial port settings on the server . Notes: 1) Serial redirection does not support hardware-based flow control. Disable the terminal flow control. 2) To prevent buffer overrun and character loss, configure both serial ports with the same baud rate.
Note: All traf fic from COM2 is now routed to the T elnet session. All traffic from the T elnet session is routed to COM2. ESC ( Note: In the default mode (EMS compatible), press Esc then the open parenthesis symbol [ ( ] to return to the command-line interface.
sequences are defined by the Microsoft Windows Server 2003 Emergency Management Services specification. The key sequences that are supported are described in the following table.
EMS reset key sequence is not available, and the Remote Supervisor Adapter II will not issue the EMS acknowledgment when the enter key sequence is accepted. 5. At the bottom of the page, click Save . 6. To begin using the new settings, in the left navigation pane, click Restart ASM .
SSH This is the port for the SSH. The default is 22. SNMP Agent This is the port number for the SNMP agent that runs on the Remote Supervisor Adapter II. The default value is 161. Other valid values are in the range 1 through 65535. SNMP T raps This is the port number that is used for SNMP traps.
3. If you want to use an Ethernet connection, select Enabled in the Interface field. Ethernet is enabled by default. 4. If you want to use a Dynamic Host Configuration Protocol (DHCP) server connection, enable it by clicking either of the following choices in the DHCP field: v Enabled v Tr y DHCP server .
qualified IP host name. For example, for the fully qualified IP host name asmcard1.us.company .com, the nonqualified IP host name is asmcard1. For information about your host name, see “Setting system information” on page 12. 6. In the IP address field, type the IP address of the Remote Supervisor Adapter II.
T able 9. Advanced Ethernet setup (continued) Field Function Burned-in MAC address The burned-in MAC address is a unique physical address that is assigned to this Remote Supervisor Adapter II by the manufacturer . The address is also a read-only field.
3. In the Interface field, select Enabled . 4. In the Local IP address field, type the local IP address for the PPP interface on this Remote Supervisor Adapter II. The field defaults to 192.96.1.1. The IP address must contain four integers from 0 through 255 separated by periods and no spaces.
Note: If you plan to configure Simple Network Management Protocol (SNMP) traps on the Remote Supervisor Adapter II, you must install and compile the management information base (MIB) on your SNMP manager .
6. Set up a community to define the administrative relationship between SNMP agents and SNMP managers. Yo u must define at least one community . Each community definition consists of the following par.
1. Log in to the Remote Supervisor Adapter II where you want to configure SMTP . For more information, see Chapter 2, “Opening and using the Web interface,” on page 5. 2. In the navigation pane, click Network Protocols and scroll down to the SMTP area.
The Remote Supervisor Adapter II contains a V ersion 2.0 LDAP client that you can configure to provide user authentication through one or more LDAP servers. The LDAP server that is to be used for authentication can be discovered dynamically or manually preconfigured.
Service Name The DNS SRV request that is sent to the DNS server must also specify a service name. The configured value is used. If this field is left blank, the default value is ldap. The DNS SRV request must also specify a protocol name. The default is tcp and is not configurable.
Binding Method Before the LDAP server can be searched or queried, a bind request must be sent. This parameter controls how this initial bind to the LDAP server is performed. Choose from the following three options: – Anonymously . Bind without a DN or password.
3. To configure the search attributes, use the following information. UID Search Attribute When the selected binding method is Anonymously or w/ Configured Credentials , the initial bind to the LDAP s.
The IBMRBSPermission= keyword is used to allow it to be placed anywhere in the attribute field. This enables the LDAP administrator to reuse an existing attribute, therefore preventing an extension to the LDAP schema. This also enables the attribute to be used for its original purpose.
Priority is given to login permissions that are retrieved directly from the user record. If the login permission attribute is not in the user ’s record, an attempt is made to retrieve the permissions from the groups to which the user belongs. This is done as part of the group authentication phase.
3. Yo u can configure the following parameters: Address type This is the address type that the MM SLP server listens on. If Broadcast is selected, the SLP server listens on the broadcast address of 255.255.255.255. If Multicast is selected, the SLP server listens on the IP address that is specified in the Multicast address field.
between the Remote Supervisor Adapter II and an LDAP server . If you are not familiar with the use of SSL certificates, read the information in “SSL certificate overview.” Use the following general tasks list to configure the security for the Remote Supervisor Adapter II: 1.
The function of the certificate authority is to verify the identity of the Remote Supervisor Adapter II. A certificate contains digital signatures for the certificate authority and the Remote Supervisor Adapter II.
b. Before you can enable SSL, a valid SSL certificate must be in place. c. To use SSL, you must configure a client We b browser to use SSL3 or TLS. Older export-grade browsers with only SSL2 support cannot be used. 3. In the SSL Server Certificate Management area, select Generate a New Key and a Self-signed Certificate .
4. T ype the information in the required fields and any optional fields that apply to your configuration. The fields are the same as for the self-signed certificate, with some additional fields. Read the information in the following sections for a description of each of the common fields.
Web address to the name that appears in the certificate. To prevent certificate warnings from the browser , the value that is used in this field must match the host name that is used by the browser to connect to the Remote Supervisor Adapter II. For example, if the address in the Web address bar is http://mm1 1.
name that is assigned to the Remote Supervisor Adapter II. This field can contain a maximum of 60 characters. 5. After completing the information, click Generate CSR . The new encryption keys and certificate are generated. This process might take several minutes.
10. Click Browse . 11 . Click the certificate file that you want and then click Open . The file name (including the full path) is displayed in the field next to the Browse button. 12. Click Import Server Certificate to begin the process. A progress indicator is displayed as the file is transferred to storage on the Remote Supervisor Adapter II.
SSL client trusted certificate management The secure SSL client (LDAP client) uses trusted certificates to positively identify the LDAP server . A trusted certificate can be the certificate of the certificate authority that signed the certificate of the LDAP server , or it can be the actual certificate of the LDAP server .
The Remove button is now available for the T rusted CA Certificate 1 option. If you want to remove a trusted certificate, click the corresponding Remove button. Yo u can import other trusted certificates using the T rusted CA Certificate 2 and the T rusted CA Certificate 3 Import buttons.
Secure Shell users are authenticated by exchanging user ID and password. The password and user ID are sent after the encryption channel is established. The user ID and password pair can be one of the 12 locally stored user IDs and passwords, or they can be stored on an LDAP server .
3. Click Enabled in the SSH Server field. 4. In the navigation pane, click Restart ASM to restart the Remote Supervisor Adapter II. Using the Secure Shell server If you are using the Secure Shell client that is included in Red Hat Linux version 7.3, to start a Secure Shell session to a Remote Supervisor Adapter II with network address 192.
1. Log in to the Remote Supervisor Adapter II where you want to back up your current configuration. For more information, see Chapter 2, “Opening and using the Web interface,” on page 5. 2. In the navigation pane, click Configuration File . 3. In the Backup ASM Configuration area, click view the current configuration summary .
Note: The security settings on the Security page are not restored by the restore operation. To modify security settings, see “Secure Web server and secure LDAP” on page 53. 7. After receiving a confirmation that the restore process is complete, in the navigation pane, click Restart ASM ; then, click Restart .
2. If you are running Internet Explorer or Netscape Navigator , click Ye s in the confirmation window . The current browser window closes to maintain security . Yo u must manually close other open browser windows, if any , to prevent a cached version of your user ID and password from remaining available.
68 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User ’s Guide.
Chapter 4. Monitoring remote server status Use the links under the Monitors heading of the navigation pane to view the status of the server that you are accessing.
v Either a red circle that contains an X or a yellow triangle that contains an exclamation point and the phrase One or more monitored parameters are abnormal If the monitored parameters are operating outside normal ranges, a list of the specific abnormal parameters is displayed on the System Health Summary page.
Note: The hard shutdown alert is sent only if a soft shutdown alert has not yet been sent. If the system is monitored by a baseboard management controller (BMC) instead of the Remote Supervisor Adapter II, the IPMI thresholds that are supported by the BMC are displayed on the T emperature Thresholds page.
Soft Shutdown When the voltage drops below or exceeds a specified voltage range, a voltage alert is sent to configured remote alert recipients, and the server begins the shutdown process with an orderly operating-system shutdown. The server then turns itself off.
operating-system loader screen. Only error conditions are captured and maintained. The Remote Supervisor Adapter II stores only the most recent error event information, overwriting older information when a new error event occurs. To remotely access a server operating-system-failure screen image, complete the following steps: a.
The event log has a limited capacity . When that limit is reached, the older events are deleted in a first-in, first-out order . Yo u can sort and filter entries in the event log. To access and view the event log, complete the following steps: 1. Log in to the Remote Supervisor Adapter II.
V iewing vital product data When the server starts, the Remote Supervisor Adapter II collects system, basic input/output (BIOS) information, and server component vital product data (VPD) and stores it in nonvolatile memory . Yo u can access this information at any time from almost any computer .
T able 13. Component activity log Field Function FRU number Identifies the field replaceable unit (FRU) number (a seven-digit alphanumeric identifier) of the component. Serial number Identifies the serial number of the component. Manufacturer ID Identifies the manufacturer of the component.
T able 16. ASM vital product data (continued) Field Function Build ID Identifies the build IDs of the application firmware and the startup ROM firmware. File name Identifies the file names of the application firmware and the startup ROM firmware. Release date Identifies the release dates of the application firmware and the startup ROM firmware.
78 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User ’s Guide.
Chapter 5. Performing Remote Supervisor Adapter II tasks Use the functions under the T asks heading in the navigation pane to directly control the actions of the Remote Supervisor Adapter II and your server . The tasks that you can perform depend on the server in which the Remote Supervisor Adapter II is installed.
v OS booted v CPUs held in reset Restart count The Restart count field shows the number of times that the server has been restarted. Note: The counter is reset to zero each time the ASM subsystem is cleared to factory defaults. Power-on hours The Power-on hours field shows the total number of hours that the server has been turned on.
Power on server at specified time To turn on the server at a specified time and start the operating system, click Power on Server at Specified Time and set the time to turn on the server . Power off server immediately To turn off the server without shutting down the operating system, click Power Off Server Immediately .
3. Click the Cache tab. 4. Choose one of the following options: v Clear the Enable Caching check box. If you choose this option, Java caching is always disabled. v Click Clear Caching . If you choose this option, you must click Clear Caching after each Remote Supervisor Adapter II firmware update.
console and the login session. After a short delay , you can log in to the adapter again with a new session, start the remote console again, and exit the server Configuration/Setup Utility program.
v SUSE Linux version 8.0 v Novell NetWare 6.5 2. The client system requires Microsoft Windows 2000 or later and the Java 1.4 Plug-in or later . 3. The client system must have an Intel ® Pentium ® III microprocessor or greater , operating at 700 MHz or faster , or equivalent.
maximum of one drive or image can be stored on the Remote Supervisor Adapter II. The size of the drive or image contents must be 1.44 MB or smaller . Important: Yo u will lose the disk image when the Remote Supervisor Adapter II is restarted or the Remote Supervisor Adapter II firmware is updated.
1) In the Microsoft Windows Control Panel, click Add/Remove Hardware ; then, click Next . 2) Select Uninstall/Unplug a device ; then, click Next . 3) Click Unplug/Eject a device ; then, click Next . b. Select USB Mass Storage Device and click Stop . c.
3. Use the following information to complete the quick setup information: Serial pass-thru The serial data of the server is directed to COM1 and then passes through to COM2. The pass-thru data can be accessed through COM2. The Remote Supervisor Adapter II command line interface (CLI) is also accessible through COM2.
Updating firmware Use the Firmware Update option on the navigation pane to update the firmware of the Remote Supervisor Adapter II. Notes: 1. To remotely update the firmware or operating system on the server , see “Remote disk” on page 83.
12. Click OK to close the current browser window . 13. Repeat step 2 on page 88 through step 12 for each packet that you must update. 14. After the Remote Supervisor Adapter II firmware is updated, log in to the Remote Supervisor Adapter II again to access the Web interface.
the table, click the login link that corresponds to the remote system that you want to access. Then, follow the standard login procedure to gain access to that system. Direct LAN Connection Click the IP address link to bypass the ASM interconnect connection and to connect to a remote system directly through your Ethernet network.
Chapter 6. Command-line interface Use the Remote Supervisor Adapter II command line interface (CLI) to access the Remote Supervisor Adapter II or Remote Supervisor Adapter II SlimLine without having to use the Web interface. It provides a subset of the management functions that are provided by the Web interface.
Features and limitations The CLI has the following features and limitations: v Multiple concurrent CLI sessions are allowed with different access methods (T elnet, SSH, or serial). – At most, two T elnet command-line sessions can be active at any time.
v All commands have the -h, -help , and ? options, which give syntax help. All of the following examples will give the same result: x345RSA> power -h x345RSA> power -help x345RSA> power ? v Some of the commands listed in the following sections might not be available.
Monitor commands The monitor commands are as follows: v clearlog v fans v readlog v syshealth v temps v volts clearlog command Description Use the clearlog command to clear the event log of the Remote Supervisor Adapter II or Remote Supervisor Adapter II SlimLine.
8 I SERVPROC 12/18/03 10:09:25 Ethernet[0] Link Established at 100Mb, Full Duplex. 9 I SERVPROC 12/18/03 10:09:24 Ethernet[0] configured to do Auto Speed/Auto Duplex.
3.3v 3.35 2.80 2.95 3.05 3.10 3.50 3.65 3.70 3.85 12v 12.25 11.10 11.30 11.50 11.85 12.15 12.25 12.40 12.65 -5v -5.10 -5.85 -5.65 -5.40 -5.20 -4.85 -4.
power command Syntax power on power off [-s] power state power cycle [-s] Description Use the power command to control the server power . To issue the power commands, you must have power and restart access authority . power on turns on the server power .
Description Use the console command to start a serial redirect console session to the designated serial port of the Remote Supervisor Adapter II or the Remote Supervisor Adapter II SlimLine.
Option Description -d Assigned domain name -dns1 Primary DNS server IP address -dns2 Secondary DNS IP address -dns3 T ertiary DNS server IP address ifconfig command Syntax ifconfig eth0 [ options ] if.
Option Description V alues -m MTU Numeric between 60 and 1500 -l LAA MAC address format. Multicast addresses are not allowed (the first byte must be even). -ri Remote IP address V alid IP address format -a Authentication protocol pap, chap, cthenp Example x345RSA> ifconfig eth0 -state enabled -c dthens -i 192.
The following table shows the arguments for the options. Option Description V alues -a User authentication method Local only , LDAP only , local first then LDAP , LDAP first then local -b Binding meth.
ntp command Syntax ntp [ options ] options: -en state -i hostname -f frequency -synch Description Use the ntp command to display and configure the Network T ime Protocol (NTP).
Option Description -exp Maximum password age [0 - 365] days. Set to 0 for no expiration. -cnt Number of previous passwords that cannot be reused [0 - 5] -nul Allows accounts with no password [yes | no.
Option Description V alues -climode CLI mode none, cliems, cliuser v none: The command-line interface is disabled v cliems: The command-line interface is enabled with EMS-compatible keystroke sequence.
Description Use the srcfg command to configure the serial redirection. T ype srcfg to display the current configuration. To change the serial redirect configuration, type the options, followed by the values. To change the serial redirect configuration, you must have at least Adapter Networking and Security Configuration authority .
Parameters The following parameters are presented in the option status display for the ssl command and are output only from the command-line interface: Server secure transport enable This status display is read-only and cannot be set directly . Server Web/CMD key status This status display is read-only and cannot be set directly .
Configuration - Networking & Security or Adapter Configuration - Advanced (Firmware Update, Restart ASM, Restore Configuration) authority level. The following table shows the arguments for the options. Option Description V alues -t T imeout A timeout value in seconds, up to a maximum of 4 294 967 295.
x345RSA> timeouts -p 5 -o 2.5 -l 3.5 -f 3 -n 1 users command Syntax users [ options ] options: - user number -n username -p password -a authority level Description Use the users command to access all user accounts and their authority levels, and to create new user accounts and modify existing accounts.
11. <not used> 12. <not used> x345RSA> users -7 -n sptest -p PASSW0RD -a custom:am|rca|cel|nsc|ac ok x345RSA> users 1. USERID Read/Write Password Expires: no expiration 2. test Read/Write Password Expires: no expiration 3. test2 Read/Write Password Expires: no expiration 4.
v For +10, the daylight saving time settings are as follows: off, ea (Eastern Australia), tas (T asmania), vlad (Vladivostok). v The year must be from 2000 to 2089, inclusive. v The month, date, hours, minutes, and seconds can all be single-digit values (for example, 9:50:25 instead of 09:50:25).
Example x345RSA> update -v -i 192.168.70.120 -l dev.pkt TFTP file upload successful 1253022. Starting flash packet preparation. Flash preparation - packet percent complete 24. Flash preparation - packet percent complete 48. Flash preparation - packet percent complete 72.
11 2 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User’s Guide.
Appendix A. Getting help and technical assistance If you need help, service, or technical assistance or just want more information about IBM products, you will find a wide variety of sources available from IBM to assist you.
Getting help and information from the World W ide Web On the World Wide W eb, the IBM Web site has up-to-date information about IBM systems, optional devices, services, and support. The address for IBM System x ™ and xSeries ® information is http://www .
Appendix B. Notices This information was developed for products and services offered in the U.S.A. IBM may not offer the products, services, or features discussed in this document in other countries. Consult your local IBM representative for information on the products and services currently available in your area.
BladeCenter Predictive Failure Analysis XA-32 Chipkill ServeRAID XA-64 e-business logo ServerGuide X-Architecture Eserv er ServerProven XpandOnDemand FlashCopy System x xSeries i5/OS Intel, Intel Xeon, Itanium, and Pentium are trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.
IBM makes no representation or warranties regarding non-IBM products and services that are ServerProven ® , including but not limited to the implied warranties of merchantability and fitness for a particular purpose. These products are offered and warranted solely by third parties.
11 8 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User’s Guide.
Index A alerts configuring recipients for 23 forwarding from ISMP 25 gateway (forwarding) 25 ISMP , gateway to network 25 selecting to send critical 27 system 29 warning 28 setting remote attempts 26 .
H hardware service and support 11 4 help, getting 11 3 host server startup sequence, changing 8 I IBM Support Line 11 4 initialization-string guidelines for modem 33 IP address, default static 5 ISMP .
Remote Supervisor Adapter II (continued) configuring 11 features 1 functions 1 logging in to Web interface 5 monitoring and configuring 36 SlimLine 1 requirements operating system 3 Web browser 3 rest.
web site (continued) support line, telephone numbers 11 4 122 Remote Supervisor Adapter II SlimLine and Remote Supervisor Adapter II: User ’s Guide.
.
Part Number: 43W7827 Printed in USA (1P) P/N: 43W7827.
デバイスIBM Remote Supervisor Adapter IIの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
IBM Remote Supervisor Adapter IIをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIBM Remote Supervisor Adapter IIの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。IBM Remote Supervisor Adapter IIの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。IBM Remote Supervisor Adapter IIで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
IBM Remote Supervisor Adapter IIを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIBM Remote Supervisor Adapter IIの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、IBM Remote Supervisor Adapter IIに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIBM Remote Supervisor Adapter IIデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。