Industrial ScientificメーカーATX612の使用説明書/サービス説明書
ページ先へ移動 of 17
P/N 1706-3421 REV 03 Printed 0900-2000 Specifications Subject to Change 1001 Oakdale Road, Oakdale, P A 15071-1500 (412) 788-4353 • T oll Free 1-800-DETECTS F AX 412-788-8353 • Service Dept. 1-888-788-4353 Multi-Gas Monitor AT X 612 Instruction Manual GUARANTEED.
OUR MISSION Design - Manufactur e - Sell: Highest quality pr oducts for the pr eservation of life and pr operty . Pr ovide: Best customer service available.
Dear V alued Customer , Thank you for buying and using Industrial Scientific’ s Model A TX612 Multi-Gas Monitor . Y our A TX612 can be relied upon for dependable service, day after day . It has been designed, manufactured, tested and proven under the most scrutinizing conditions possible.
Multi-Gas Monitor AT X 612 1. W ARNINGS AND C AUTIONAR Y S T A TEMENTS 3 2. U NP ACKING T HE I NSTRUMENT 4 3. A TX612 F EA TURES 4 4. I NSTRUMENT O PERA TION 5 4 .1 Charging the Battery 5 4.1.1 Alkaline Battery Option 8 4 .2 Turning the A TX612 On and Off 8 4.
4 5 2. U NP ACKING THE I NSTRUMENT The shipping box should contain the following items. Account for each item before discarding the box. Q UANTITY P ART N UMBER D ESCRIPTION 1 1810-2707 A TX612 Multi-.
INDUSTRIAL SCIENTIFIC ATX612 OXYGEN LEL E BATT PPM % ON/OFF MODE 6 7 Hidden (+) Key Alarm Speaker On/Off/Mode Key Ultra-bright V isual Alarm Light Bar Battery Status Indicator Hidden (-) Key Display E.
8 9 CO H2S 02 LEL ATX612 VER 1.0 5 O 0 21.0 0 The remote sample tube should be connected to the barbed inlet fitting on the bottom of the A TX612 (See Figure 3). NOTE: When drawing a r emote sample, allow 2 seconds per foot (0.3 meter) of tubing length in addition to the normal sensor r esponse time befor e observing the instrument r eadings.
10 11 4.6.2 HIGH ALARM When a monitored gas concentration reaches the high alarm level setpoint, the instrument emits a continuous dual tone alarm. As with the low alarm condition, the red alarm light bar and backlight will flash simultaneously with the displayed gas value.
12 13 ZERO PRESS ZEROING 21.0 02 CAL 4.6.6 BA TTERY F AILURE When the battery has insufficient char ge to operate the instrument, “BA TTER Y F AIL” is displayed. The visual alarm will be activated and the instrument will emit a short beep once every second for approximately 30 seconds after which the instrument will turn itself off.
14 15 CODE 0 PRESS • T o continue full calibration, press (E) and the instrument will display the first sensor to be calibrated along with the calibration gas setting. The message APPL Y CAL GAS will scroll across the bottom of the display . NOTE: If the gas concentration does not match the setting, pr ess the MODE switch to abort calibration.
16 17 CODE PRESS CODE 123 PRESS • Press (+) to step to the INST ANT function and set instantaneous alarm values. The display will indicate INST ANT along with the scrolling prompt PRESS (+) FOR NEXT (E) TO SELECT . • Press (E) to enter the instantaneous alarms function.
18 19 The datalogging section of the instrument is always powered and a battery backup circuit protects it from loss of data for up to 40 minutes during battery changes. NOTE: The instrument must be stor ed on a battery char ger when not in use to pr event loss of data due to battery dischar ge.
20 21 • Remove the battery pack from the instrument as described in Section 8.2. • Remove the two screws which hold the battery module in place as shown in Figure 4. • Lift the Nicad battery module from the battery pack. • Place the new Nicad module in the battery pack.
22 23 I TEM P ART N UMBER D ESCRIPTION (Q TY ) 1 1705-8868 Main PC Board (1) 2 1705-6755 Display PC Board (1) 3 1705-9247 Interface PC Board (1) 4 1705-9031 Chassis (1) 5 1706-3447 Pump Assembly (1) 6.
24 25.
27 26 11 . D EF AUL T A LARM S ETTINGS GAS LOW ALARM HIGH ALARM O 2 19.5% 23.5% LEL 10% 20% CH 4 1.0% 1.5% CO 35 PPM 70 PPM H 2 S 10 PPM 20 PPM SO 2 2.0 PM 4.0 PPM NO 2 3.0 PPM 6.0 PPM Cl 2 0.5 PPM 1.0 PPM ClO 2 0.3 PPM 1.0 PPM NOTE: Factory alarm settings may not coincide with local r egulations.
28 29 Industrial Scientific portable gas monitoring instruments are warranted to be free from defects in material and workmanship for as long as the instrument is in service.
デバイスIndustrial Scientific ATX612の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Industrial Scientific ATX612をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIndustrial Scientific ATX612の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Industrial Scientific ATX612の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Industrial Scientific ATX612で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Industrial Scientific ATX612を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIndustrial Scientific ATX612の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Industrial Scientific ATX612に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIndustrial Scientific ATX612デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。