Par t I The Modular L YNX System Modular L YNX ! Getting Star ted ! Connecting the L YNX System ! Mounting the L YNX System ! Powering the L YNX System ! The Communications Interface ! Configuring the.
1 - 2 Modular LYNX System 12.05.2003 T able of Contents Section 1: Getting Started ..................................................................................................... .............................................. 1- 5 Section Overview .
1 - 3 Modular L YNX System Modular LYNX System 12.05.2003 T ypical Functions of the Differential I/O ...................................................................................... .............................................. 1-34 Connecting and Using an Encoder .
1 - 4 Modular LYNX System 12.05.2003 T able 7.1: Power Requirements for the L Y NX Control Module ....................................................................... ...................... 1-40 T able 7.2: L YNX Control Module LED Indicators .....
1 - 5 Modular L YNX System Modular LYNX System 12.05.2003 Section 1 Getting Started Section Overview The purpose of this section is to get you up and running quickly . This section will help you do the following: ! Connect power to the L YNX Control Module.
1 - 6 Modular LYNX System 12.05.2003 User Provided T ools and Equipment Needed ! Serial Cable ! IM483 or equivalent step motor driver ! ISP200-4 or equivalent power supply ! M-22XX or equivalent stepp.
1 - 7 Modular L YNX System Modular LYNX System 12.05.2003 Once the IMS T erminal is installed you may run the Setup. 1 ) Open the IMS T erm by clicking Start>Programs>IMS T erminal>IMS T erm. 2 ) Select or verify the Communications Port that you will be using with your L YNX.
1 - 8 Modular LYNX System 12.05.2003 Once you have been able to move the motor , the next step is to write a simple program to illustrate one of the dynamic features of the L YNX: the ability to convert motor steps to a dimension of linear or rotary distance.
1 - 9 Modular L YNX System Modular LYNX System 12.05.2003 Section 2 Connecting the L YNX System Section Overview Each module of the L YNX System is a closed unit with a header of pins and locking tabs to connect it to another module in the system. Optional I/O modules are connected on the RIGHT side of the Control Module.
1 - 10 Modular LYNX System 12.05.2003 Section 3 Mounting the L YNX System Section Overview This section covers the two basic methods of mounting the L YNX System. ! Panel Mount. ! DIN Rail Mounting Option. Panel Mount Using the panel mount option, the L YNX is designed to use #10 hardware (not included).
1 - 11 Modular L YNX System Modular LYNX System 12.05.2003 3 . Holding the L YNX System at an angle away from you, lower the upper slot of the DIN rail attachment onto the top edge of the DIN rail. Snap L YNX system into place. Figure 3.2. 4 . Insert #6 X .
1 - 12 Modular LYNX System 12.05.2003 Section 4 Powering the L YNX System Section Overview This section covers the two basic power configurations for your L YNX System. ! Basic rules of wiring and shielding. ! L YNX Control Module with IMS Drivers. ! L YNX Control Module as Stand-alone or with Optional I/O Module.
1 - 13 Modular L YNX System Modular LYNX System 12.05.2003 L YNX Control Module with IMS Driver In this example, power is connected to the L YNX Control Module via connector P1. All optional plug-on modules are then powered from the L YNX Control Module.
1 - 14 Modular LYNX System 12.05.2003 Stand-alone or with Optional I/O Modules +12 to +75VDC Supply A +12 to +75VDC unregulated supply connected to P1 provides power to the L YNX Control Module and any optional I/O modules.
1 - 15 Modular L YNX System Modular LYNX System 12.05.2003 Power Requirements ! W ARNING! When using an unregulated supply , ensure that the output voltage does not exceed the maximum driver input vol.
1 - 16 Modular LYNX System 12.05.2003 Section 5 The Communications Interface Section Overview The L YNX Control Module features two communication interfaces: RS-232 and RS-485 . For both channels, the BAUD rate is software configurated, using the BAUD variable, to 4800, 9600, 19200 or 38400 bits/sec.
1 - 17 Modular L YNX System Modular LYNX System 12.05.2003 Figure 5.1: Connecting the RS-232 Interface, Single Control Module System T able 5.1: Wiring Connections: RS-232 Interface Single Control Mod.
1 - 18 Modular LYNX System 12.05.2003 name, to identify it in the system. This can be done using configuration switches A0-A2, or by using the software command SET DN . For example, to set the name of a controller to "A" you would use the following command: SET DN = "A".
1 - 19 Modular L YNX System Modular LYNX System 12.05.2003 Figure 5.2: RS-232 Interface, Multiple Control Module System T able 5.3: Connections and Settings Multiple Control Module System, RS-232 Inte.
1 - 20 Modular LYNX System 12.05.2003 Connecting the RS-485 Interface Single Controller System In a Single Controller System, the RS-485 interface option would be used if the Control Module is located at a distance greater than 50 feet from the Host PC.
1 - 21 Modular L YNX System Modular LYNX System 12.05.2003 Multiple Controller System When using the RS-485 interface in a Multiple Control- ler System, the Host PC as well as all of the control modules communicate on the RS-485 interface.
1 - 22 Modular LYNX System 12.05.2003 T able 5.6: RS-485 Interface Connections and Settings, Multiple Control Module System Figure 5.4: RS-485 Interface, Multiple Control Module System It is also poss.
1 - 23 Modular L YNX System Modular LYNX System 12.05.2003 L YNX Control Module Modes of Operation There are three modes of operation for the L YNX control module.
1 - 24 Modular LYNX System 12.05.2003 carriage return line feed characters that are transmitted in response to the Enter key on the keyboard provided the ASCII setup specifies “Send line feeds with line ends”. Note that there need not be a space between the data for the last parameter and the CR/LF .
1 - 25 Modular L YNX System Modular LYNX System 12.05.2003 Section 6 Configuring the Digital I/O Section Overview This section covers the usage of the Isolated Digital and High Speed Differential I/O Modules which are available on the L YNX System. ! System I/O A vailability by Module.
1 - 26 Modular LYNX System 12.05.2003 The Isolated Digital I/O The L YNX CM100 Control Module has a standard set of twelve +5 to +24VDC I/O lines and the L YNX CM200 Combination Control Module has a standard set of six +5 to +24VDC I/O lines.
1 - 27 Modular L YNX System Modular LYNX System 12.05.2003 T able 6.2: IOS V ariable Settings IOS = , , X XX X X T o configu re an e nti r e I/O Grou p e nte r the Group # ( 2 0, 3 0 , 40 or 50 ) h er.
1 - 28 Modular LYNX System 12.05.2003 Configuring an Input Figure 6.2 below illustrates the Input Equivalent Circuit of the Isolated I/O being used with a switch. T o illustrate the usage of an input you will go through the steps to configure this switch to start a simple program at Line 1000 to index a motor 200 user units.
1 - 29 Modular L YNX System Modular LYNX System 12.05.2003 Configuring an Output Figure 6.3 illustrates the Output equivalent circuit of the Isolated I/O. When used as an output the I/O line is able to sink 350mA continuous for each output, or a total of 1.
1 - 30 Modular LYNX System 12.05.2003 Read/Write an I/O Group When using the IO variable to read the state of a group of inputs/outputs, or write to a group of outputs you would first want to configure the entire I/O group to be general purpose inputs or outputs using the IOS variable.
1 - 31 Modular L YNX System Modular LYNX System 12.05.2003 The Differential I/O The Clock Interface The L YNX has four clock pairs that are used by the high speed I/O.
1 - 32 Modular LYNX System 12.05.2003 Configuring The Differential I/O - The IOS V ariable The high speed differential I/O is configured by means of the IOS variable, and is used in the the same fashion in which the isolated I/O is configured.
1 - 33 Modular L YNX System Modular LYNX System 12.05.2003 is demonstrated in T ypical Functions of the Differ ential I/O: Connecting and Using an Encoder .
1 - 34 Modular LYNX System 12.05.2003 T ypical Functions of the Differential I/O Connecting and Using an Encoder The differential I/O module can be set up to receive encoder feedback using either a differential or a single ended output encoder .
1 - 35 Modular L YNX System Modular LYNX System 12.05.2003 Figure 6.8: Connecting and Using an Encoder DIR + DIR - SCK- SCK+ GND +5V RX- RX+ TX - TX + CG ND RX TX 22 21 23 24 25 26 31 32 33 34 35 36 I.
1 - 36 Modular LYNX System 12.05.2003 Half Axis Operation (Follower) In half axis mode the master clock is taken from a clock input 2, 3 or 4 (line pairs 13-14, 15-16 or 17-18) which have been set for input, clock type and ratio enabled.
1 - 37 Modular L YNX System Modular LYNX System 12.05.2003 DIR+ DIR- SCK- SCK+ GND +5V RX- RX+ TX- TX+ CGND RX TX 22 21 23 24 25 26 31 32 33 34 35 36 IG 123 456 123 456 123 45 6 22 21 23 24 25 26 31 3.
1 - 38 Modular LYNX System 12.05.2003 NOTE: The RA TIO variable must be set to less than 2 or -2 or Error Code 9004, “Ratio Out of Range” will occur .
1 - 39 Modular L YNX System Modular LYNX System 12.05.2003 Section 7 The L YNX Contr ol Module (LX-CM100-000) Section Overview This section will cover: ! Hardware Specifications ! Environmental Specif.
1 - 40 Modular LYNX System 12.05.2003 Power Requirements Connection Overview Figure 7.2: LYNX Control Module, Switches and Connections T able 7.1: Power Requirements for the LYNX Control Module s n o .
1 - 41 Modular L YNX System Modular LYNX System 12.05.2003 Pin Assignment and Description LED Indicators r o l o C D E L g n i n a e M n e e r Gn O r e w o P d e R e h t g n i t t e s y b r o t a c i d n i e h t e l b a s i d r o e l b a n e o t e s o o h c n a c r e s u e h T .
1 - 42 Modular LYNX System 12.05.2003 Switch Assignments O / I l a t i g i D d e t a l o s I : r o t c e n n o C l a n i m r e T e l b a e v o m e R n o i t i s o P 3 1 - 3 P # n i P n o i t c n u F n.
1 - 43 Modular L YNX System Modular LYNX System 12.05.2003 Section 8 The L YNX Contr ol Module (Combination) Section Overview The Control Module (Combination) (IMS Part # LX-CM200-000) offers the user of purchasing a L YNX Control Module with 3 differential I/O Channels and 6 Isolated I/O lines instead of the standard 2 Isolated I/O groups.
1 - 44 Modular LYNX System 12.05.2003 Power Requirements Connection Overview Figure 8.2: LYNX Control Module (Combination) Connections and Switches T able 8.
1 - 45 Modular L YNX System Modular LYNX System 12.05.2003 Pin Assignment and Description LED Indicators r o l o C D E L g n i n a e M n e e r Gn O r e w o P d e R e h t g n i t t e s y b r o t a c i d n i e h t e l b a s i d r o e l b a n e o t e s o o h c n a c r e s u e h T .
1 - 46 Modular LYNX System 12.05.2003 s t u p n I g n i s i c r e x E r o f e l b a s U , e m i T y n a t a d e g n a h C e B n a C : s e h c t i w S p U - l l u P O / I 0 2 p u o r G # h c t i w S n o i t c n u F n o i t p i r c s e D 6 - 1 s e h c t i w S l a u d i v i d n I 0 2 p u o r G O / I r o f .
1 - 47 Modular L YNX System Modular LYNX System 12.05.2003 Section 9 The Isolated Digital I/O Module Section Overview The Isolated I/O Module (IMS Part # LX-DI100-000) offers the user an additional 12.
1 - 48 Modular LYNX System 12.05.2003 Pin Assignments And Description Connection Overview 12 3 456 42 41 43 44 45 46 123 45 6 51 52 53 54 55 56 ISOLA TED I/ O M ODU L E 42 41 43 44 45 46 51 52 53 54 5.
1 - 49 Modular L YNX System Modular LYNX System 12.05.2003 Switch Assignments And Description Input Specifications Figure 9.3: LYNX Isolated I/O Input Equivalent Circuit s t u p n I g n i s i c r e x .
1 - 50 Modular LYNX System 12.05.2003 Input Filtering User definable Digital filtering makes the L YNX well suited for noisy industrial environments. The filter setting is software selectable using the IOF V ariable with a minimum guaranteed detectable pulse width of 18 microseconds to 2.
1 - 51 Modular L YNX System Modular LYNX System 12.05.2003 Section 10 The Differential Digital I/O Module Section Overview A L YNX system may contain an optional Differential I/O Module (IMS Part# LX-DD100-000) which provides six (6) high speed differential I/Os.
1 - 52 Modular LYNX System 12.05.2003 Power Requirements Power is supplied through the L YNX Control Module. DI FFERENTIAL I/ O MODULE 13+ 13- 14- 14+ 15- 15+ 16- 16+ 17- 17+ 18- 18+ PGND TM Grou p 10 H igh Sp eed I /O P1 Grou nd Connection Overview Figure 10.
1 - 53 Modular L YNX System Modular LYNX System 12.05.2003 Pin Assingments And Description Input Specifications s n o i t a c i f i c e p S t u p n I O / I l a i t n e r e f f i D d e e p S h g i H d l o h s e r h T t u p n I l a i t n e r e f f i DV 2 .
1 - 54 Modular LYNX System 12.05.2003 Input Filtering User definable Digital filtering makes the L YNX well suited for noisy industrial environments. The filter setting is software selectable using the IOF V ariable with a minimum guaranteed detectable pulse width of 18 microseconds to 2.
1 - 55 Modular L YNX System Modular LYNX System 12.05.2003 Output Specifications Figure 10.4: LYNX Differential I/O Output Equivalent Circuit s n o i t a c i f i c e p S t u p t u O O / I l a i t n e r e f f i D d e e p S h g i H d a o L o N d a o L A m 6 0 c i g o L - e g a t l o V t u p t u OV 5 .
1 - 56 Modular LYNX System 12.05.2003 Intentionally Left Blank.
デバイスIntelligent Motion Systems Modular LYNX Systemの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Intelligent Motion Systems Modular LYNX Systemをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIntelligent Motion Systems Modular LYNX Systemの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Intelligent Motion Systems Modular LYNX Systemの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Intelligent Motion Systems Modular LYNX Systemで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Intelligent Motion Systems Modular LYNX Systemを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIntelligent Motion Systems Modular LYNX Systemの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Intelligent Motion Systems Modular LYNX Systemに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIntelligent Motion Systems Modular LYNX Systemデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。