Tankless W ater Heater System Design Manual Plumbing schematics for single and multiple tankless water heaters in use with domestic systems, recirculation, and storage tanks.
2 Certifications .................................................................................. 3 Water Quality and Scale ................................................................ 4 Pump Sizing for Circulation ..............................
3 Approvals Certified to applicable U.S. standards for appliances using gas or other petroleum fuel. Certified to applicable Canadian standards for appliances using gas or other petroleum fuel. Certified by the Uniform Plumbing Code (UPC) Certified by National Sanitation Foundation (NSF), www.
4 W ater Quality and Scale A complete water analysis and an unde rstanding of system requirements are needed to prote ct the tankless water heaters and water heating systems from scale. Water analysis shows whether water is hard or soft. Hard water, unless treated, will cause scaling or liming of the heat exchanger.
5 Pump Sizing for Circulation 1. Use the chart below or one appropriate for your co nditions to determine the heat loss in the length of the hot water supply and return piping. For example, 100 ft of 1-1/2 in bare copper tubing results in a heat loss of 5300 Btu/h.
6 T ank W ater Heaters in a Circulation Loop The following applies when using a tank water heater (gas or electric) to provide heat for a circulation loop. Drawing WH-1-RGE is an example. The heat output of the tank must be equal to or greater than the calculated circulation loop heat loss.
The following applies when using tankless water heaters to recover a storage tank. Drawing WH-1-B is an example. Tankless water heaters have a pressure loss which must be considered in the system design. Reference the pressure loss curve for the heater m odel being used to determine the pump size for the desired recovery rate.
8 Pressure Loss Curves Pressure Loss (psi) Water Flow (gpm) 0. 0 5. 0 10. 0 15. 0 20. 0 25. 0 30. 0 35. 0 40. 0 45. 0 01 234 56 789 1 0 1 1 0. 0 10. 0 20.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e W.
23 Domestic Hot Water - Circulation Systems 3 Tankless Water Heaters with Gas or Electric Tank Preferred Piping Installation Tankless Water Heater Tankless Water Heater Drawing Number: Drawing Date: P.
24 Tankless Tankless Tankless Tankless Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pu.
25 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
26 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
27 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
28 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Va.
29 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion Ch e c k V a l ve Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Va.
30 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
31 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
32 Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv .
Drawing Number: Drawing Date: Pres s ure R elief Valv e 3/ 4" Ball Valv e 3/ 4" U nion C hec k Valv e Ke y S Pres s ure R egulat or C irc ulating Pum p Solenoid Valv e Boiler D rain Valv e M.
34 Notes.
35 Notes.
• 500 T ennessee Waltz Parkway • Ashland, TN 37015 •.
デバイスAmerican Water Heater GTS-305-PEの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
American Water Heater GTS-305-PEをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmerican Water Heater GTS-305-PEの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。American Water Heater GTS-305-PEの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。American Water Heater GTS-305-PEで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
American Water Heater GTS-305-PEを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmerican Water Heater GTS-305-PEの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、American Water Heater GTS-305-PEに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmerican Water Heater GTS-305-PEデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。