Gardtec 350+ 2897PDF GARDINER TECHNOLOGY Gar dtec 350+ Quic k Star t User Guide.
Intr oduction This Quick Start Guide is intended to help end users who are new to security systems in the da y to da y use of the system. W e recommend that this guide is used in conjunction with the end user manual that w as supplied with the control panel.
T ampers & P As Y our security system protects itself against tamper ing. In the e vent of an y control equipment, detectors or sounders being opened or cables being cut the internal and/or the e xter nal will sound. Dependant on the le v el of system you ha v e installed this ma y require an engineer call-out to reset the system.
P o wer LED The P ower LED giv es an indication of that the mains supply to the unit is good. It should be illuminated at all times e xcept when User Programming mode is being used.
T o P art Set the System Then retire to an unprotected area Note: Y our engineer ma y hav e programmed the P ar t Set e xit sounders as silent. If so a single beep will be giv en when the e xit time e xpires.
Resetting After An Alarm After an alar m all the LEDs will be flashing. Pressing No will displa y the cause of the alar m f or 3 seconds. F or example . System is Unset. Z 3 illuminated. All LEDs are flashing. Zone 3 was activ ated when system was set.
User Pr ogramming Mode T o enhance the flexibility of the Gardtec 350 control panel there are fiv e user programmab le options av ailable . When programming the user options the displa y is via the fiv e zone LEDs and the legend to the right of the LEDs is used (see illustration belo w).
TEST This option allows a Master User to test the system z ones and sounders. LOG This option allows a Master User to vie w the system Ev ent Log. CHIME One or more system zones ma y hav e been programmed as chime z ones b y your installation engineer .
The displa y will show . If you wish to Remo v e more zones return to * OR T o set the system with the Zone(s) you selected Remov ed Exit Wa i t After e xiting and securing the premises alwa ys wait until the e xit sounders hav e stopped bef ore leaving.
The displa y will show . The displa y will show . The displa y will show . When you ha ve finished testing the system press. This is T est Mode. Y ou ma y now ‘walk T est’ the system. Each time you activ ate a zone the inter nal sounder will sound and the corresponding LED will illuminate on the control panel.
Vie wing The Log With the system in Da y Mode (Unset). The displa y will show . The displa y will show . The displa y will show ..
The displa y will now sho w the last system e v ent and will v ar y dependant on what that e v ent was . Whilst using the Log Mode the No ke y is used to move to the pre vious ev ent and the Y es ke y is used to move to the ne xt ev ent.
T urning Chime On/Off Chime zones will ha v e been pre viously programmed b y your installation engineer . A Master le v el user ma y tur n the Chime function On or Off . Zones that are programmed as Chime z ones will giv e a low le vel ‘beep’ sequence when activated.
The displa y will show . The displa y will show . T o Escape back to Da y Mode. Pr ogramming User Codes Up to nine user codes ma y be programmed into the 350+ control panel, each user code has a predeter mined le v el of access.
The sequence f or programming User Codes is . Enter User Code Programming Mode Enter the User Number (1 to 9) you wish to progr am Enter the Code you require f or the User Re-Enter the Code you require f or the User Retur n to Da y Mode This is shown step b y step below .
The displa y will show . The displa y will show . The displa y will show ..
The displa y will show . The displa y will show . The displa y will show . Enter User Number (1 to 9) Note: T amper LED has rapid flash Enter New Code Note: T amper LED has slow flash.
The displa y will show . The displa y will show . T o Escape back to Da y Mode Note: T o delete a User Code enter 0000 as the New Code . User Number 1 is the main system code, theref ore it may only be changed and not deleted. Additional inf ormation is contained within the User Manual that was supplied with the Gardtec 350 Contr ol Panel.
デバイスAmeriGlide GARDTEC 350+の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
AmeriGlide GARDTEC 350+をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAmeriGlide GARDTEC 350+の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。AmeriGlide GARDTEC 350+の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。AmeriGlide GARDTEC 350+で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
AmeriGlide GARDTEC 350+を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAmeriGlide GARDTEC 350+の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、AmeriGlide GARDTEC 350+に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAmeriGlide GARDTEC 350+デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。