omega.com e-mail: info@omega.com For latest product manuals: omegamanual.info EP510, IP510, EP511, IP511 SERIES Electr oneumatic Conver ters Shop online at U ser ’ s Guide MADE IN.
Servicing Nor th America: U.S.A.: Omega Engineering, Inc., One Omega Drive, P.O. Box 4047 ISO 90 01 Cer tif ied Stamford, CT 06907-0047 USA Toll Free: 1-800-826-6342 TEL: (203) 359-1660 FAX: (203) 359-7700 e-mail: info@omega.
A IR CONNECTIONS S UPPLY Connect air supply to 1/4 NPT port marked "IN." If the above specifications are not met, possibility of internal clogging exists.
M EP510 AND IP510 OUNTING GENERAL NEMA 1 and NEMA 4X transducers can be mounted in any position. DIRECT MOUNTING PIPE • Any NEMA 1 transducers may be supported by its own plumbing for air supply and output. NEMA 4X transducers may also be supported using 1/2" explosion proof conduit in the electrical port.
E LECTRICAL CONNECTIONS P RECAUTIONS TO BE OBSERVED DURING INSTALLATION These Transducers were tested at the EMC Test Centre, Dunfermline, Fife, KY11 5LB to the Electromagnetic Compatibility Directive effective January 1, 1996. The relevant EMC specifications tested were the following: EN 50081-1 (1992) and EN 50082-2 (1992).
WARNING: In explosive atmospheres, electrical power must be removed from the transducer before attempting to remove the cover and until the cover is fully reinstalled. Failure to do so may result in electrical spark or explosion. CAUTION: Only attempt electrical adjustments as described below.
R EPLACING ORIFICE: T his can be accomplished without removing the unit from its mounting or plumbing. 1. Turn off supply pressure and unscrew the brass orifice assembly located on the side of the housing with the gauge port. NOTE: Small sealing o-ring may remain inside of the housing.
EXPLOSION & DUST-IGNITION PROOF CERTIFICATIONS F ACTORY MUTUAL and CANADIAN STANDARDS ASSOCIATION WARNING: The following ratings are valid ONLY WHEN the cover is installed for FM and CSA. BOTH the cover and the locking device, using tamper resistant screws must be installed.
M- 410 9/1 10 4 I P5 10, EP 51 0, IP 511 , EP5 11 SE RIE S A 9 TABLE 5: KITS KIT NAME PART NUMBER 1. Panel Mounting Kit 010135-000 2. Valve Mounting Kit 010134-000 3. 2" Pipe Mounting Kit (Valve Mounting Kit is required) 010143-000 4. DIN Rail Adapter 010115-000 5.
M- 410 9/1 10 4 I P5 10, EP 51 0, IP5 11 , E P5 11 SE RIE S A 10 510 and 511 Series I/P AND E/P TRANSDUCER SPECIFICATIONS Accuracy: ± 0.10% of output span, typical ± 0.25% of output span, maximum Hysteresis: 0.01% of output span, typical 0.10% of output span, maximum Dead Band: Not measurable Repeatability: 0.
W ARRANTY / DISCLAIMER OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months fro m da te of pu rcha se. OMEGA ’ s W ARRANTY adds an additional one (1) month grace period to the normal one (1) year product warranty to cover handling and shipping time.
M4109/0909 Where Do I Find Ever ything I Need for Pr ocess Measurement and Control? OM EGA…Of Course! Shop online at omega.com SM TEMPERA TURE 䡺 ⻬ Thermocouple, RTD & Thermistor Probes, Conn.
デバイスIomega EP510の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Iomega EP510をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはIomega EP510の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Iomega EP510の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Iomega EP510で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Iomega EP510を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はIomega EP510の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Iomega EP510に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちIomega EP510デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。