TECHNICAL MANUAL INST ALLA TION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS Jackson MSC LLC. P .O. Box 1060 Barbourville, KY . 40906 (606) 523-9795 Fax: (606) 523-9196 www .
ALL NEW JACKSON DISHW ASHERS ARE W ARRANTED TO THE ORIGINAL PURCHASER T O BE FREE FROM DEFECTS IN MA TERIAL OR WORKMANSHIP , UNDER NORMAL USE AND OPERA TION FOR A PERIOD OF (1) ONE YEAR FROM THE DA TE OF PURCHASE, BUT IN NO EVENT T O EXCEED (18) EIGHTEEN MONTHS FROM THE DA TE OF SHIPMENT FROM THE F ACT ORY .
3 ST OP! PA R E ! ARRET! CALL 1-88 8-800-5672 TO REGISTER THIS PRO DUCT! F AILURE TO DO SO WILL VOID THE W ARRAN TY! LL AME AL 1-888-80 0-5672 P AR A REGISTR AR ESTE P RODUCTO! AL NO HACERL O L A GARANTIA SERA AN UL ADA! S.
i REVISION/ P AGE REVISION DA TE MADE BY APPLICABLE ECN DET AILS A 1 1-19-2004 MAW 7202 Initial release of manual. B 03-17-2005 MA W 7253, 7272 6999 Added hose connections, curtain inst allation & det ailed instruction pages. Updated limit switch actuators.
ii NOMENCLA TURE FOR THE MODELS COVERED IN THIS MANUAL TS-44GP TS = T raditional Series of rack conveyors TSC = T raditional Series (water conserver) of rack conveyors 44 = 44” wide machine 66 = 66” wide machine No suffix = Electrically heated, hot water sanitizing machine GP = Gas heated, hot water sanitizing machine Model: Serial No.
SECTION DESCRIPTION P AGE I. SPECIFICA TION INFORMA TION Operating Characteristics 2 Electrical Requirements TS-44/TSC-44 3 Electrical Requirements TS-66/TSC-66 3 TS-44/TSC-44 Dimensions 4 TS-66/TSC-6.
Pawl Bar Assemblies 66 TS/TSC-44 Rack Rail Assembly 67 TS/TSC-66 Rack Rail Assemblies 68 Drive Assembly 69 Float Switch Components/Scrap Basket Assembly 72 Miscellaneous Parts & W eldments 73 S tr.
1 SECTION 1: SPECIFICA TION INFORMA TION.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION OPERA TING CHARACTERISTICS 2 RACKS PER HOUR: TS-44/TS-44GP 252 TSC-44/TS-44G.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION ELECTRICAL REQUIREMENTS 3 NOTE: T ypical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed- trip circuit breaker sizes as listed in the NEC 2002 Edition.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION TS-44/TSC-44 DIMENSIONS 4 8" 62" 17" 8" 60" 25" 21" 6" 4-1/ 2" LEFT TO RIGHT MODEL SHO WN.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION TS-44/TSC-44 DIMENSIONS (CONTINUED) 5 LEGEND FOR TS-44/TSC-44/TS-44GP/TSC-44GP DIMENSIONS: A = 1/2” IPS incoming water connection, approximately 59-1/2” above the finished floor .
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION TS-44/TSC-44 DIMENSIONS (CONTINUED) 6 NOTES CONCERNING THE TS-44/TSC-44 DIMENSIONS: 1. All dimensions are +/- 1/2” in the vertical due to adjustment of the bullet feet.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION TS-66/TSC-66 (LEFT TO RIGHT) DIMENSIONS 7 D A B C HEIGH T WITH THE DO OR OPEN IS 72". Add 3” to overall width to take into account the conduit on the back of the machine.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION TS-66/TSC-66 (LEFT TO RIGHT) DIMENSIONS (CONTINUED) 8 LEGEND FOR TS-66/TSC-66 (LEFT TO RIGHT) DIMENSIONS: A = Incoming electrical connection point, approximately 61-1/4” above the finished floor .
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION TS-66/TSC-66 (RIGHT TO LEFT) DIMENSIONS 9 A B C D Add 3” to overall width to take into account the con- duit on the back of the machine.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION TS-66/TSC-66 (RIGHT TO LEFT) DIMENSIONS 10 LEGEND FOR TS-66/TSC-66 (RIGHT TO LEFT) DIMENSIONS: A = Incoming electrical connection point, approximately 61-1/4” above the finished floor .
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION DISHT ABLE DIMENSIONS 11 “C” 8” 12 1/2” 4 1/2” 25” 8” T ABLE TO T ABLE 4” “B” “A” 10 1/2” 21” OPENING 4” wide x 16” long vent connection in splash shields.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION SIDE LOADER (LEFT TO RIGHT) DIMENSIONS 12 NOTE: ALL DIMENSIONS ARE TYPICAL. 23” or 30” depending on the width of the side loader .
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION SIDE LOADER (RIGHT TO LEFT) DIMENSIONS 13 NOTE: ALL DIMENSIONS ARE TYPICAL. 14 1/2” 29” 8” or 15” depending on the width of the side loader .
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION SIDE LOADER (INST ALLED) DIMENSIONS 14 Refer to chart above.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION SCRAP TROUGH DIMENSIONS 15 NOTE: DIMENSIONS ARE TYPICAL FOR BOTH ENDS.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 1: SPECIFICA TION INFORMA TION TYPICAL ELECTRIC AND GAS BOOSTER DIMENSIONS 16 3 4 /" N P T Cou pling f.
17 SECTION 2: INST ALLA TION & OPERA TION INSTRUCTIONS.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 2: INST ALLA TION/OPERA TION INSTRUCTIONS INST ALLA TION INSTRUCTIONS 18 VISUAL INSPECTION: Before installing the unit, check the container and machine for damage.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 2: INST ALLA TION/OPERA TION INSTRUCTIONS INST ALLA TION INSTRUCTIONS (CONTINUED) 19 ELECTRICAL POWER CONNE.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 2: INST ALLA TION/OPERA TION INSTRUCTIONS INST ALLA TION INSTRUCTIONS (CONTINUED) 20 CHEMICAL FEEDER EQUIPM.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 2: INST ALLA TION/OPERA TION INSTRUCTIONS DELIMING OPERA TIONS 21 DELIMING OPERA TIONS: In order to maintain the dishmachine at it s optimum performance level, it will be required to remove lime and corrosion deposits on a frequent basis.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 2: INST ALLA TION/OPERA TION INSTRUCTIONS CURT AIN INST ALLA TION DIAGRAMS 22 TS SERIES MACHINES 44 S 12&qu.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 2: INST ALLA TION/OPERA TION INSTRUCTIONS SIDE LOADER INST ALLA TION & OPERA TION INSTRUCTIONS 23 This accessory assists in the delivery of a full dish rack from the break down (scrapping) t able to the dishmachine.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A 24 SECTION 2: INST ALLA TION & OPERA TION INSTRUCTIONS DISHMACHINE OPERA TING INSTRUCTIONS PREP ARA TION: Before proceeding with the start-up of the unit, verify the following: 1.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A 25 SECTION 2: INST ALLA TION & OPERA TION INSTRUCTIONS DETERGENT CONTROL Detergent usage and water hardness are two factors that contribute greatly to how efficiently your dishmachine will operate.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A 26 SECTION 2: INST ALLA TION & OPERA TION INSTRUCTIONS STRIKER PLA TE LIMIT SWITCH INST ALL TION INSTRUCTIONS TABLE LIM I T SWITCH THROUGH ROD HOLES TABLE SWITCH RO DS STRIKE PLAT E STRIKE PLATE BOLTS MOUNTING BOLTS TABLE BOTT OM 3.
27 SECTION 3: PREVENT A TIVE MAINTENANCE.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 3: PREVENT A TIVE MAINTENANCE PREVENT A TIVE MAINTENANCE The dishmachines covered in this manual are designed to operate with a minimum of interaction with the operator .
29 SECTION 4: TROUBLESHOOTING.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 4: TROUBLESHOOTING COMMON PROBLEMS 30 W ARNING: Inspection, testing and rep air of electrical equipment should only be performed by a qualified ser- vice technician.
TS Series Conveyors T echnical Manual 7610-002-98-29 Issued: 02-15-2006 Revised: N/A SECTION 4: TROUBLESHOOTING COMMON PROBLEMS 31 Problem: Racks go through the machine, but result s are poor . 1. V erify that detergent is being dispensed into the machine at the appropriate quantities for the water volume.
デバイスJackson TSC-44GPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Jackson TSC-44GPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはJackson TSC-44GPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Jackson TSC-44GPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Jackson TSC-44GPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Jackson TSC-44GPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はJackson TSC-44GPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Jackson TSC-44GPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちJackson TSC-44GPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。