SEDONA ™ Steam & Shower Base INST ALLA TION/OPERA TING INSTRUCTIONS.
IMPORT ANT SAFETY INFORMA TION READ ALL INSTALLATION INSTRUCTIONS Jacuzzi Whirlpool Bath does not recommend prolonged periods of use of the steamer. Prolonged use of the steam system can raise excessively the internal human body temperature and impair the body’s ability to regulate its internal temperature (hyperthermia).
CONTENTS Specifications _________________________________________________________________________ 2 Roughing-in Reference _________________________________________________________________ 2 Framing an.
*SteamPro supplied with NEMA 6-50P plug. NEMA 6-50R receptacle required. Product specifications are subject to change without notice. SPECIFICATIONS DIMENSIONS 60" (1524 mm) L 32" ( 813 mm) W 18-5/8" ( 473 mm) H TOTAL WEIGHT/ FLOOR LOADING 310 lbs (141 kg) /23 lb/sq.
10-1/2" x 5" DRAIN CUT -OUT 15-3/8" 33-1/4" 60-1/4" FRONT OF DOUBLE STUDS SUB-FLOOR 90º 90º MINIMUM 6" FROM FINISHED CEILING OR BOTTOM OF OPTIONAL DOME TO TEMPERA TURE .
4 Drain Down Locations There are several locations (left hand unit shown) where the optional automatic valve may be located when connecting to a drain line as shown in illustration. Right hand unit is mirror image. Exact location to be determined by installer.
5 Minerals in the water or poor water quality can shorten the life of the steam generator or cause erratic operation if the tank is not drained regularly. Drain the tank frequently. Jacuzzi Whirlpool Bath also strongly recommends purchasing and installing the optional automatic drain down valve.
6 SHUT OFF V AL VE WA TER SUPPL Y (3/8" COPPER TUBING) W ater Supply Consult local authorities for plumbing code require- ments in your area. Connect house cold water supply to steam generator supply tubing. IMPORTANT: Jacuzzi Whirlpool Bath does not warrant connections of water supply fittings and piping or drain systems.
7 Controller Mounting Finished Wall Mounting The low voltage control can be mounted directly to a finished wall either inside or outside the steam room. Using a 2" hole saw, drill a hole in the finished wall where the control is to be mounted (the control cable should already be roughed-in to this location).
8 W ALL PROBE MUST POINT DOWNW ARD 7/8" HOLE OPTIONAL TRIM RING SILICONE SEALANT PIGT AIL Flange Mounting After base is in position secure flange to studs with screws provided.
9 Service Access Service access is through the removable panel. To remove panel, grab the middle of the panel and bow outwards till clips disengage. SERVICE ACCESS P ANEL GRAB P ANEL IN MIDDLE AND BOW.
10 REMOVE SCREWS MOUNTING BRACKET SHIPPING RESTRAINT WA TER SUPPL Y SHUT OFF V AL VE TO STEAM HEAD DRAIN DOWN Maintenance of the SteamPro Unit Maintenance of the SteamPro includes flushing and visually inspecting for water leaks. To remove the unit remove the access panel.
11 T roubleshooting There are no user serviceable parts in the Generator. All repair should be performed by a qualified service person. For additional assistance or the factory authorized service person nearest you call the Service Department at 1-800- 363-0251 (This number is only for service for the steam generator.
12 T roubleshooting.
13 W iring Diagram.
14 ©2002 Jacuzzi Whirlpool Bath T87100B 2/04 Jacuzzi Whirlpool Bath National Headquarters P.O. Drawer J, Walnut Creek, CA 94596 (925) 938-7070 Service Support: Call (800) 288-4002 Jacuzzi Whirlpool Shower base has obtained applicable code (standards) listings generally available on a national basis for products of this type.
Jacuzzi Whirlpool Bath C/O AMEREC P.O. Box 2258 Woodinville WA, 98072 Jacuzzi Whirlpool Bath, warrants that its Steam Generators (warranted products) are free of manufacturing defects both as to workm.
6. Procedure. Requests for repair or replacement, a return authorization number, or warranty information should be directed to AMEREC by calling toll-free 1-800-363-0251 or by writing to AMEREC, 17683 128th Place N.
Jacuzzi Whirlpool Bath Limited W arranty Builder Gr oup Bath Pr oduct Jacuzzi Whirlpool Bath P .O. Drawer J W alnut Creek, CA 94596-9885 WARRANTY COVERAGE Jacuzzi Whirlpool Bath (the “Company”) of.
RESPONSIBILITIES OF OTHERS Inspecting the unit prior to installation is the responsibility of the installer or building contractor who acts on behalf of the user. They are responsible for ensuring the unit is free of defect or damage. Notices are placed on and in the unit and on the shipping carton advising the installer of this responsibility.
デバイスJacuzzi SEDONAの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Jacuzzi SEDONAをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはJacuzzi SEDONAの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Jacuzzi SEDONAの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Jacuzzi SEDONAで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Jacuzzi SEDONAを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はJacuzzi SEDONAの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Jacuzzi SEDONAに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちJacuzzi SEDONAデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。