JLAメーカー/T75の使用説明書/サービス説明書
ページ先へ移動 of 32
T20 / T30 / T50 / T75 Installa tion/Oper a tor Manual Part No. 1 13429 - 9 JLA Limited Meadowcroft Lane, Halifax Road Ripponden West Y orkshire, England HX6 4AJ T elephone: 01422 822282 / Fax: 01422 8.
2 JLA Limited 1 13429 - 9 “IMPORT ANT NOTE T O PUR CHASER” Information must be obtained from your local gas supplier on the instructions to be followed if the user smells gas. These instructions must be posted in a prominent location near the dryer .
1 13429 - 9 T elephone 01422 822282 3 IMPORT ANT Y ou must disconnect and lockout the electric supply and the gas supply or the steam supply before any covers or guards are removed from the machine to allow access for cleaning, adjusting, installation, or testing of any equipment per OSHA standards.
4 JLA Limited 1 13429 - 9 Safety Precautions ____________________ Warning For your safety , the information in this manual must be followed to minimize the risk of fire or explosion and to prevent property damage, personal injury , or loss of life. The dryer must never be operated with any of the back guards, outer tops, or service panels removed.
1 13429 - 9 T elephone 01422 822282 5 ! ! ! ! NOTES ______________________________________________________ _____________________________________________________________ _______________________________.
6 JLA Limited 1 13429 - 9 MA X I MUM C A PAC I TY (D RY WE IG HT ) 2 0 l b 9.07 kg T U M B L E R D I A M E T E R 25- 3/4” 65. 41 cm T U MBLER DEPT H 2 4 ” 60 . 96 cm T U M B L E R V O L U M E 7- 1/2 c u f t 212. 38 L TUM B L E R/ D R I V E M OTOR 1 / 4 h p 0.
1 13429 - 9 T elephone 01422 822282 7 T20 Specifications __________________________________________________________________.
8 JLA Limited 1 13429 - 9 MA X I MUM C A PAC I TY (D RY WE I GHT ) 3 0 l b 13. 61 kg T U MBLER DI AMET ER 3 0 ” 76.20 cm T U MBLER DEPT H 2 7 ” 68.58 cm T UM BLER VOLU ME 11 . 0 4 c u ft 312. 62 L TUM B L E R/ D RIV E MO TOR 1 / 4 h p 0.19 kW BLO WER / F AN M OT O R 1 /2 hp 0.
1 13429 - 9 T elephone 01422 822282 9 T30 Specifications __________________________________________________________________.
10 JLA Limited 1 13429 - 9 M AXI MU M CAP ACI T Y ( DR Y WEI GH T ) 50 lb 22.68 kg T U MBL ER DI AMET ER 3 7” 93.98 cm T U M B L ER DE PT H 25- 3/ 4” 65.41 cm TU MB L E R V OL UME 1 6 . 0 2 c u f t 453.64 L TU MB L E R/D RI V E MOTO R 3 / 4 h p 0.
1 13429 - 9 T elephone 01422 822282 11 T50 Specifications __________________________________________________________________.
12 JLA Limited 1 13429 - 9 MA X I MUM C A PAC I TY (D RY W E I GHT ) 7 5 l b 34 .02 k g T U M BLER DI AMET ER 3 7 ” 93.98 cm T U M B L E R D E P T H 35-1/ 2” 90.17 cm T U M B L E R V O L U M E 22. 09 cu ft 625. 52 L TUMBL ER/D RI V E MOTO R 3 / 4 h p 0.
1 13429 - 9 T elephone 01422 822282 13 T75 Specifications __________________________________________________________________.
14 JLA Limited 1 13429 - 9 ! Installation Procedures _______________ Installation should be performed by competent professional in accordance with local, state, and country codes. In the absence of these codes, the installation must conform to applicable American National S tandards: ANSI Z223.
1 13429 - 9 T elephone 01422 822282 15 EXAMPLE: For T50, 2 unrestricted openings measuring 6-inches by 24-inches (15.24 cm by 60.96 cm) are acceptable. If a closet door is installed: unobstructed air openings are required. The air openings shall be located 3-inches (7.
16 JLA Limited 1 13429 - 9 ! NOTE 1 Opening from combustible materials must be 2-inches (5.08 cm) larger than the duct (all the way around). The duct must be centered within this opening. NOTE 2 Distance should be 2 times the diameter of the duct to the nearest obstruction.
1 13429 - 9 T elephone 01422 822282 17 Impor tant No more than 4 dryers should be connected to 1 main common duct. The illustration below shows the minimum cross-sectional area for multiple dryer round or square venting.
18 JLA Limited 1 13429 - 9 Warning (Gas Models Only) Dryers built for use with a voltage between 200 and 240 must verify the input voltage during installation.
1 13429 - 9 T elephone 01422 822282 19 Electric Models Only All electrically heated dryers must be connected to the electric service shown on the dryer’s data label.
20 JLA Limited 1 13429 - 9 3-Phase (3ø) Wiring Connections/Hookup 200-240V Application without Neutral ! Caution The dryer must be grounded. A ground lug has been provided for this purpose. Input connection wiring must be sized properly to handle the dryer ’s current draw .
1 13429 - 9 T elephone 01422 822282 21 ! ! Gas Infor mation________________________ It is your responsibility to have all plumbing connections, materials, and workmanship conform to local and state regulations or codes of the country of destination.
22 JLA Limited 1 13429 - 9 Heat Input/Gas Consumption/Orifice (Injector) Data (For Non CE [European] Models Only) Shaded areas are stated in metric equivalents * Gas valve’s internal regulator disabled. * * Consult factory for elevations over 2,000 feet (610 meters) for correct orifice size.
1 13429 - 9 T elephone 01422 822282 23 Piping/Connections CE dryer connections will be B.S.P .T ., all others will be N.P .T . There should be a minimum 6-inch (15.24 cm) clearance between the back guard and the first bend in the gas piping for ease of servicing.
24 JLA Limited 1 13429 - 9 Conv er ting fr om One F amil y of Gas to Another ______________________ Warning (CE Dr yers) This appliance must only be operated with the gas type indicated on the dryer’s data plate.
1 13429 - 9 T elephone 01422 822282 25 ! ! ! R e gulated Gas V alv e Refer to “Gas Pressure Adjustment” on this page to adjust the gas valve to the appropriate burner pressure listed on page 22. The supply pressure must also match what is listed on page 22 for the type of gas to be used.
26 JLA Limited 1 13429 - 9 ! ! Gas Pressur e T esting _________________ For proper operation, the gas pressure must be correct, consistent and maintained at the gas pressure rates shown on page 22. Provisions are made at the gas valve for taking gas pressure readings.
1 13429 - 9 T elephone 01422 822282 27 ! ! ! ! ! Steam Requirements – High Pressure Shaded areas are stated in metric equivalents * The minimum operating pressure for optimum results is 100 psig (689.
28 JLA Limited 1 13429 - 9 ! ! ! ! Impor tant Flexible supply line/coupling must be used. Solenoid valve failure due to hard plumbing connections will void warranty . The dryer is to be connected to the water mains using a new hose set and the old hose set should not be reused.
1 13429 - 9 T elephone 01422 822282 29 ! ! Preoper ational Instructions __________ Impor tant For more detailed information regarding the microprocessor controller (computer), refer to the microprocessor user’s manual included with the dryer.
30 JLA Limited 1 13429 - 9 Note Be sure to include the installation date when returning the warranty card(s). War ranty For a copy of the commercial warranty covering your particular dryer(s), contact the distributor from whom you purchased the equipment and request a dryer warranty form.
1 13429 - 9 T elephone 01422 822282 31 CE Label Data Label Infor mation _____________________________________________________________ Standard Label When contacting JLA, the information on the data label is required to ensure proper service/parts assistance.
Part No. 1 13429 9 - 07/15 /08 - 50.
デバイスJLA /T75の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
JLA /T75をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはJLA /T75の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。JLA /T75の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。JLA /T75で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
JLA /T75を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はJLA /T75の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、JLA /T75に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちJLA /T75デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。