JMR electronicメーカーG5312の使用説明書/サービス説明書
ページ先へ移動 of 48
H1 Chaparral G5312 10-bay Rackmount & T ower Enclosur es Installation Guide July 16, 2002 • Revision C Patent Pending.
FORTRA H1 Chaparral G5312 Installation Guide Rev C ii Copyright Copyright 2000, 2001 by JMR Electronics, Inc. All Rights Reserved. No part of this publication may be reproduced, transmitte.
FORTRA H1 Chaparral G5312 Installation Guide Rev C iii T able of Contents 1. Intr oduction 2/4/6/8/10/12/15-Bay Product Family Features . . . . . . . . . . . . . . . . . . . . . .1-1 10-bay Rackmount Specifications . . . . . . . . . . . . . . .
Front Status LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3 External I/O Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-3 Connections & LEDs . . . . . .
Part 1 Basic Software Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-2 Part 2 FOR TRAÒ SAF-TE Commands . . . . . . . . . . . . . . . . . . . . . . . .9-5 Command Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FORTRA H1 Chaparral G5312 Installation Guide Rev C 1-1 The 10-bay FOR TRA H1 Chaparral G5312 is designed to be used with a host system to provide a high-end RAID storage solution.
FOR TRA products use advanced mid-plane technology developed by JMR, which allows power supplies, drives, and all other enclosure components to interface into a single board. This provides superior performance and easy connectivity . The host interface supports one SCSI-2 host connection and two SCSI-2 disk connections.
Power Supply (Each power supply includes internal cooling fan) Quantity: 2 Power: 430 W atts each (N+1) Power Factor Correction Input: 100-260 V AC; 50-60Hz Output: +5V @ 35A +12V @ 30A Blower Quantity: 2 Size: 97mm (3.82") each Air Flow: 25.42CFM (0.
FORTRA H1 Chaparral G5312 Installation Guide Rev C 2-1 This chapter covers specification information for all FOR TRA enclosures. The following matrix describes the available configurations for FOR TRA and StorBlade TM enclosures.
Environmental Specifications Operating T emperature: 5°C to 40°C (41°F to 104°F) Storage T emperature: 0°C to 65°C (32°F to 149°F) The maximum recommended ambient temperature depends on the recommendation of the manufacturer for the devices being installed.
Thermal Specifications FOR TRA enclosures have been designed to meet the air-flow/cooling requirements for popular 7,200, 10,000, and 15,000 RPM disk drives. Using high performance blowers, air is pulled in from all open vents and exhausted out the back of the unit.
FORTRA H1 Chaparral G5312 Installation Guide Rev C 3-1 This chapter covers SCSI device installation for 10-bay rackmount and 10-bay tower enclosures. SCA Connection and Hot-Swapping The unit uses SCA-2 (80-pin) connectors which provide a safe means of connection/disconnection when hot-swapping devices.
Drive Installation Device mounting screws are included with the unit for device mounting. The JMR part number for the #6-32" mounting screws is HDS-01906. 1. After removing the canister , place it on a static free surface along with the device to be installed.
4. Repeat steps 1 through 3 until all devices are installed, then move onto step 5 to complete unit setup and installation. 5. For 10-bay rackmount units, refer to Chapter 7 to install the enclosure into a cabinet. 6. Establish host connection. See Chapter 4 for SCSI host connection.
FORTRA H1 Chaparral G5312 Installation Guide Rev C 4-1 This chapter covers SCSI device setup and option settings. Please take note of the installation warnings below before beginning setup. Slot Settings The pictures below show the slot numbering sequence and the default ID settings.
Available ID's Each bus is allowed to have ID's that range from 0-15. No two devices on the same bus may share the same ID. Each host controller always uses one ID. The on-board SAF-TE processor uses one ID which defaults to ID 5 of bus A. ID Conflict When two devices share the same SCSI ID, a conflict occurs.
Front Status LEDs A status indicator is located on each canister . A ' Blue ' light indicates normal drive activity . A ' Red ' light indicates a device fault. If all canisters display a ' Red ' light that is blinking on and off it indicates that there is a system fault.
Channel A Out HD-68 female connector . Drive connection for daisy-chaining Chan A to other external enclosures. Channel B Out HD-68 female connector . Drive connection for daisy-chaining Chan B to other external enclosures. RS232 DB-9, RS-232 Serial Connection for G5312 controller .
This chapter covers all operations of the blowers for 10-bay units. Refer to Chapter 1 for blower specifications. The blowers are hot swappable and can be removed or installed while the enclosure cont.
User ’ s removing or installing a blower must be aware of the blower access hole. Contact with the access hole must be avoided while the blower is running to prevent injury . Blower Replacement If the blower has stopped running or the fault LED indicator is lit, the blower may need to be replaced.
This chapter covers all operations of the power supplies. For operation, the AC cord (included) must be connected to the AC Inlet on each supply , and the power supply must be switched ON. The 'OK LED' will light to indicate the power supply is functioning properly .
Low Power Mode (Standby Power) When both power supplies are turned off, the unit will switch to low power or standby mode and the power supply fans will continue to run. The unit blowers will remain operational if a single power supply is turned off, not installed, or fails, in order to maintain the proper low temperature within the unit.
FORTRA H1 Chaparral G5312 Installation Guide Rev C 7-1 This chapter covers the installation of the Rackmount enclosure into a standard 19" (483mm) wide and 30" (762mm) to 36" (914mm) deep cabinet that meets the EMA/RETMA standards.
Rail Mounting Kit Hardware • T en #10-32 Screws • Four each #8-32 Screws/W ashers/Nuts Spare Hardware Parts Check with a JMR Sales Representative for pricing and availability of spare hardware parts.
2. Affix the extension bracket to the rear of the unit using two #10-32 screws. There are 3 holes in the extension bracket for mounting. Depending on the hole pattern that is being used in the cabinet, two holes should always be available for securing the extension bracket.
4. Slide the unit into the cabinet and secure it to the cabinet with a single #10-32 screw on each side. 5. Snap the end cap over the screw on each side of the unit to finish the installation.
The FOR TRA H1 Chaparral G5312 is designed to be used with one G5312 SCSI to SCSI RAID bridge controller from Chaparral. The unit provides one SCSI L VD SCSI-2 host connection and two SCSI L VD SCSI-2 (80MB/s) device channels which are backwards compatible with SE SCSI.
ID Settings & Option Jumpers Refer to Chapter 4 and Chapter 9 for SCSI ID settings and option jumper settings. Controller Canister Installation 1. Remove the four cover screws on the controller canister using a Phillips head screwdriver and lift the cover off the canister .
FORTRA H1 Chaparral G5312 Installation Guide Rev C 9-1 For bus management, the FOR TRA 10-bay SCSI RAID enclosures have a SAF-TE (SCSI Accessed Fault-T olerant Enclosure) processor designed to the ANSI approval version 2.0 of the SAF-TE specification.
DOS Installation 1. Insert the JMR Utility disk into the floppy drive. 2. Change to the floppy drive that the JMR Utility disk is in. Example: At the DOS command prompt, type A: and press ENTER . 3. At the disk command prompt ( A:> ), type CD DOS and press ENTER .
The following Figure shows the host adapter selection screen. From this screen the host adapter to be communicated with can be chosen. The example shows that there are two host adapters installed in the system. This next screen shows how the target device may be selected.
This next screen shows the T est Unit Ready Screen . If the unit is online and ready , the dialog box will report T arget [x] Ready . If the unit is offline, the dialog box will report T arget [x] Not Ready . 'x' is the number of the target that was selected previously and any commands that are initiated will only affect that target.
This screen shows the Spin up/down Unit Screen . These commands are only effective when using hard disk drives. The Spin up Unit command will power on the target device. The Spin down Unit command will power off the tar get device. Just as a precaution, it is safer to spin a device down before removing it to prevent damage.
Command Overview FORTRA H1 Chaparral G5312 Installation Guide Rev C 9-6 T est Unit Ready Reports if communication is established between a host adapter and the SAF-TE processor . Inquiry Reads device firmware and identifies device part number , firmware revision and other information.
The I nquiry Scr een lists some of the settings of the unit that may be useful during troubleshooting. The V endor ID, Product ID, and Product Revision Level are shown at the bottom of the screen. When troubleshooting, it is important to check that the Product Revision Level is at the most recent.
The Enclosur e Status Scr een , will report the status of the blowers, power supplies, slot SCSI ID's, system temperature, and slot temperature. The Usage Statistics Scr een , will report how many hours the system has been in operation for and how many times it has been turned on and off.
The Power Supply Ena/Dis Scr een , allows each power supply to be turned off (disable), or turned on (enable). From the rear of the unit, power supply 1 is on the left hand side, and power supply two is on the right hand side. The Fan Setup Scr een , allows for manual control of the blowers.
The Slot Operation Scr een , allows flags to be set for each individual slot. The menu has two submenus; first select the slot and second, select the operation to be performed on the selected slot. After a selection of the slot, status may be checked in the Slot Status Scr een .
The Firmwar e Options scr een is used to read the current firmware settings of the unit and to load new settings into the unit from disk. The Display EEPROM command will show the current firmware settings. Display disk File will load an EEPROM file from a disk and display it to the screen.
EETBL.ASM Default Settings File LINE HEADING SETTING DESCRIPTION 1 EEDFTTBL: DB 85 ;55H CHECKSUM 2 DB 255 ;0FFH 3 DB 0 ;NONE = 0, MASTER = 1, SLAVE = 2 4 DB 10 ;NUMBER OF CANISTERS 5 DB 11 ;CANISTER S.
44 DB 0 ; MSB BYTE 45 DB 0 ;NUMBER OF INSERTION IN SLOT 2 LSB BYTE 46 DB 0 ; MSB BYTE 47 DB 0 ;NUMBER OF INSERTION IN SLOT 3 LSB BYTE 48 DB 0 ; MSB BYTE 49 DB 0 ;NUMBER OF INSERTION IN SLOT 4 LSB BYTE.
command. JMR Electronics, Inc. has implemented all of the SAF-TE commands in the SAF-TE specification including the optional commands, to ensure compatibility with other vendors. All of the SAF-TE commands can be accessed through the utility software even if the host adapter has not implemented it or does not support the command.
Read Enclosure Configuration Command Read enclosure status is a mandatory SAF-TE command that reports to the host what components are installed in the enclosure. This will only read the unit that the SEP is installed on, not any unit connected via S-Link.
Send Global Command Send global command is a mandatory SAF-TE command that is used to send commands that apply to the entire enclosure globally rather than to a specific device, channel, or device slot.
Optional SAF-TE Commands *Activate Power Supply Command Activate power supply is an optional SAF-TE command that is used to turn the selected power supply on or off.
FORTRA H1 Chaparral G5312 Installation Guide Rev C 10-1 For current information on this product, including updates to the manual and technical support related issues, please contact the sales support section of our web page at www .jmr .com, or you can contact our T echnical Support division directly at the address below .
FORTRA H1 Chaparral G5312 Installation Guide Rev C A-1 Drive Manufacturers Fujitsu Internet Address: www .fcpa.com Hitachi Internet Address: www .hitachi.com IBM (International Business Machines Corporation) Internet Address: www .ibm.com Maxtor Internet Address: www .
Host Bus Adapter Manufacturers Adaptec, Inc. Internet Address: www .adaptec.com Antares Microsystems Internet Address: www .antares.com Emulex Corporation Internet Address: www .emulex.com JNI Corporation Internet Address: www .jni.com QLogic Corp. Internet Address: www .
デバイスJMR electronic G5312の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
JMR electronic G5312をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはJMR electronic G5312の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。JMR electronic G5312の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。JMR electronic G5312で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
JMR electronic G5312を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はJMR electronic G5312の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、JMR electronic G5312に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちJMR electronic G5312デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。