OWNER'S MANUAL MODEL NO. 625.384700 Caution: Read and Follow All Safety Rules and Operating Instructions Before First Use of This Product. If you have questions when installing, operating or maintaining your reverse osmosis system, call this toll-free number.
- WARRANTY- 1 li I I /liJ I Ill li I I _ I Ill I / I lill_ I FULL WARRANTY ON REVERSE OSMOSIS DRINKING WATER SYSTEM = = (except filter cartridges and R.
- TABLE OF CONTENTS - Where To Install the RO System ........ 4 Tools and Materials Needed ........... 4 Installation Steps .................... 5- 9 Cold Water Supply .................. 5 Drain Adapter ..................... 6 Faucet .................
- WHERE TO INSTALL THE RO SYSTEM - The RO assembly and storage tank is designed for installation under the sink, usually in the kitchen or bathroom. The RO assembly mounts on a wall sur- face, or can lay on the cabinet floor next to the storage tank. Hanger washers and wood screws are included for cabinet wall mounting.
- STEP 1: INSTALL COLD WATER SUPPLY FITTING - Check and comply with local plumbing codes as you plan, then install a cold feed (supply) water fitting. The fitting must provide a leak- tight connection to the RO 1/4" tubing (see FIG. 8, page 8). A typical connection using the included water supply fitting is shown in FIG.
- STEP 2: INSTALL DRAIN ADAPTER - • Note: Running the drain tubing directly to a floor drain, sump, standpipe, laundry tub, etc., as shown on page 18, is preferred. However, if that is not pos- sible or practical, the included drain adapter installs in the sink drain pipe, always above or ahead of the p-trap (FIG.
- STEP 3: INSTALL FAUCET (cont.)- B. ASSEMBLE FAUCET 1. If not already assembled, install the rubber washer, spacer, flat (or lock) washer and hex nut onto the threaded faucet stud. 2. Apply Teflon tape to the end of the faucet stud. Turn the tubing adapter with a blue collet onto the stud and hand tighten, then wrench 1/4 turn only.
- STEP 5: INSTALL STORAGE TANK, MAKE REMAINING TUBING CONNECTIONS - 1. CONNECT DRAIN TUBING, FAUCET TO DRAIN ADAPTER: Referring to FIG. 8, run the loose section (connected to faucet barb fitting) of black 3 / 8" tubing from the faucet to the drain adapter, with a black collet, installed on page 6.
- STEP 6: SANITIZING, PRESSURE TESTING & PURGING - SANITIZING Sanitizing is recommended upon installation of the RO system, and after servicing inner parts. It is im- portant for the service person to have clean hands while handling inner parts of the system.
- HOW YOUR REVERSE OSMOSIS SYSTEM WORKS - PREFILTER Water from the cold supply pipe enters the RO as- sembly prefilter first (FIG. 8 and schematic below).
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - To keep your reverse osmosis system operating and producing high quality water, you must make sure supply water is always within the limits shown in the specifications. Good supply water helps to assure longer life from the RO membrane cartridge, prefilter and postfilter cartridges.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - 2. Press inward while turning the RO cap to the left (_) to remove from the bracket/membrane housing. 3. Use a pliers, or heavy wire made into a hook, to pull the RO cartridge from the housing. Note: Sanitizing is recommended after servicing in- ner parts of the system (see page 9).
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - TUBING CONNECTION (continued) If tubing other than tubing supplied with the system is used, be sure it is of high quality, exact size and roundness with a smooth surface. AUTOMATIC SHUTOFF SERVICE If the shutoff assembly requires service, be sure to reassemble parts exactly as shown in FIG.
- CARE OF YOUR REVERSE OSMOSIS SYSTEM - REVERSE OSMOSIS SYSTEM CARE GUIDE MODEL NO. 625.384700 1. AT LEAST every 6 months, replace the prefilter and postfilter cartridges.
- DIMENSIONS and SPECIFICATIONS - 15" Supply water pressure limits ........................ 40 - 125 psi Supply water temperature limits ..................... 40 - 100 °F Maximum total dissolved solids (TDS) ............... 2000 ppm Maximum water hardness @ 6.
- REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Model No, 625.384700 33 !DRA , t ADAPTER 34 ! Bracket!Membrane Housing PUSH - IN FITrlNGS ] CO et 24 I 26 1/4" Tubing _ U 35 _10_ _ o-ring seals j3 I" I I 21 20 19 1 I I I I I .
Key NO. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 - REPAIR PARTS - Kenmore Reverse Osmosis Drinking Water System, Part Number 7205350 7207920 7185788 42-34702 71771.
- REMOTE LOCATION FOR REVERSE OSMOSIS SYSTEM - REMOTE RO INSTALLATION (storage tank not shown) Possible remote locations for the RO nearby the kitchen or bathroom sink include; (1) a basement area underneath the sink, and (2) an adjacent room or closet.
19.
OWNER'S MANUAL MODEL NO. 625,384700 The model number of your reverse osmosis system is found on the rating decal. This decal is on the top of the bracket.
デバイスKenmore 625.3847の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Kenmore 625.3847をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKenmore 625.3847の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Kenmore 625.3847の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Kenmore 625.3847で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Kenmore 625.3847を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKenmore 625.3847の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Kenmore 625.3847に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKenmore 625.3847デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。