Kenmoreメーカー721.80524の使用説明書/サービス説明書
ページ先へ移動 of 18
IVlodels/lViodelos 721.80402 721.80403 721.80404 721.80409 721.80522 721.80523 721.80524 721.80529 Read and save these installation instructions. Lea y guarde estas instrucciones de instalaci6n INSTRUCTIONS p _rowave Hood Combination Combinaci6n Microondas Campana 0 i=.
YOUR SAFETY FIRST BEFORE YOU START • Proper installation is the installer's responsibility! - Read the entire manual before you begin. - The model number label is located on the oven front. See Figure 1. - Mounting plate is located on back side of microwave oven.
YOUR SAFETY FIRST • THIS APPLIANCE MUST BE GROUNDED! - If there is an electrical short circuit, grounding reduces the risk of electrical shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug.
YOUR SAFETY FIRST • MAKE SURE YOU HAVE ENOUGH SPACE AND SUPPORT. - Mount the oven against a flat, vertical wall, so that it is supported by the wall. The wall should be constructed of minimum 2" x 4" wood studding and 3/8" thick drywall or plaster/lath.
PARTS, TOOLS, MATERIALS THE FOLLOWING PARTS ARE SUPPLIED WITH THE OVEN: NOTE: Depending on your ventilation requirements, you may not use all of these parts.
PARTS, TOOLS, MATERIALS YOU WILL NEED THE FOLLOWING TOOLS AND MATERIALS FOR THE INSTALLATION: Carton or other heaw material for covering the counter top.
STEP 1: PREPARE THE ELECTRICAL CONNECTIONS _k WARNING _k AVOID ELECTRICAL SHOCK! THIS APPLIANCE MUST BE GROUNDED! 1. Locate the grounded electric outlet for this oven in the cabinet above the oven, as shown in Figure 4 Detail. NOTE: The outlet should be on a circuit dedicated to the microwave oven 120V, 60Hz.
STEP 2: PREPARE THE VENTING S YSYTEM NOTE: The ductwork you need for outside ventilation is not included with your oven. The standard ductwork fittings and length are shown in Figure 9, page 9.
STEP 2: PREPARE THE VENTING S YSYTEM STANDARD FITTINGS NOTE: If the existing duct is round, you must use a rectangular-to-round adapter, with a rectangular 3" extension duct installed between the damper assembly and the adapter to prevent the exhaust damper sticking.
STEP 3: PREPARE THE VENTING BLOWER Your microwave oven is shipped with the blower assembled for room venting (recirculating). You need to adjust the blower if you want wall vented or roof vented installation. A. WARNING _k ELECTRICAL SHOCK HAZARD! UNPLUG UNIT BEFORE WORKING ON IT.
STEP 3: PREPARE THE VENTING BLOWER WALL VENTED INSTALLATION: 1. Remove two blower unit mounting screws and one or two blower plate screws. Remove the blower plate from cabinet. See Figure 12. 2. Carefully lift the blower unit out of the microwave oven.
STEP 3: PREPARE THE VENTING BLOWER ROOF VENTED INSTALLATION: 1. Remove two blower unit mounting screws and one or two blower plate mounting screws. Remove the blower plate from cabinet. See Figure 18. blower plate mounting screws 2. Carefully lift the blower unit out of the microwave oven.
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION MEASURE AND TACK / TAPE UP THE TEMPLATE 1. Using a plumb line and (metal) measuring tape, find and mark the vertical center line (_ on the back wall, as in Figure 22. 2. Find and mark one or two points where the studs are on the wall (Studs are normally 16 inches apart.
STEP 4: PREPARE THE WALL AND UPPER CABINET FOR INSTALLATION DRILL THE HOLES IN THE WALL AND UPPER CABINET. A, WARNING _, BE VERY CAREFUL WHEN DRILLING HOLES INTO THE WALL. Electrical wires could be concealed behind the wall covering and if the drill hits them you could get an electric shock.
STEP 5: INSTALL THE MOUNTING PLATE TO THE WA L L THE OVEN MUST BE CONNECTED TO AT LEAST ONE WALL STUD. 1. Draw a vertical line on the wall at the center of the 30" wide space. Use the mounting plate as the template for the rear wall. Place the mounting plate on the wall, making sure that the tabs are against the bottom of the cabinet.
STEP 5: INSTALL THE MOUNTING P L ATE TO THE WA L L TO PREPARE THE REAR WALL CUTOUT OPENING AND EXHAUST ADAPTOR/MOUNTING PLATE FOR WALL VENTING AND ROOF VENTING: NOTE: If room vented installation is used, skip this step. 1. Place the mounting plate against the rear wall as described in step 5 item 1 (page 15).
STEP 6: ATTACH THE OVEN TO THE WALL _k WARNING A, You will need two people to lift this microwave. Failure to use more than one person could result in personal injury. 1. Carefully lift microwave oven and hang it on support tabs (See Figure 26) at the bottom of the mounting plate.
STEP 6: ATTACH THE OVEN TO THE WALL 5. Roof vented installation: See Figure 32. Install ductwork through the vent opening in the upper cabinet. Complete the venting system through the roof according to the method needed. See "PREPARE THE VENTING SYSTEM," STEP 2 on the page 8.
デバイスKenmore 721.80524の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Kenmore 721.80524をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKenmore 721.80524の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Kenmore 721.80524の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Kenmore 721.80524で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Kenmore 721.80524を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKenmore 721.80524の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Kenmore 721.80524に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKenmore 721.80524デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。