ALARM OPERATE O N T W I S T O F F S MOKE AND C ARBON M ONOXIDE A LARM M O V E T O F R E S H A I R PUSH & HOLD TO TEST WEEKL Y Battery Operated C OMBINA TION S MOKE & C ARBON M ONOXIDE A LARM User ’ s Guide LISTED Model KN-COSM-B Manual P/N 810-1191 Rev .
Thank you f or purchasing the Kidde Combination Smoke and Carbon Monoxide Alarm model # KN- COSM-B . This alarm has a five-year limited warranty . Please take a few minutes to thor oughly read this user’ s guide, and save f or future ref erence. T each childr en how to respond to the alarms, and that they should never pla y with the unit.
3 2 Product V iew Product V iew ALARM OPERA TE O N T W I S T O F F S MOKE AND C ARBON M ONOXIDE A LARM M O V E T O F R E S H A I R PUSH & HOLD TO TEST WEEKL Y 3 2 1 W ARNING: BA TTERIES MISSIN.
• One “chirp” ever y 30 seconds is an indication that the alarm is malfunctioning. If this occur s call the Consumer Hotline at 1-800-880-6788. • Seven (7) years after initial power up, this unit will “chirp” every 30 seconds to indicate that it is time to replace the alarm.
• A batter y powered alarm must have a batter y of the specified type, in good condition and installed properl y . • A.C. powered alarms (without batter y backup) will not operate if the A.C. power has been cut off, such as by an electrical fire or an open fuse.
CAUTION: This alarm will only indicate the pr esence of carbon monoxide gas at the sensor . Carbon monoxide gas may be present in other ar eas. Individuals with medical problems ma y consider using war ning devices which provide audib le and visual signals f or carbon monoxide concentrations under 30 ppm.
Mobile Homes: Mobile homes built within the last five to sev en years are designed to be energy efficient. Install Smoke/CO alarms as recommended above.
Install at least one (1) foot a wa y from f luorescent lights, electronic noise may cause nuisance alarms. Do not place in direct sunlight and keep out of insect infested areas. Extreme temperatures will effect the sensitivity of the Smoke/CO Alar m. Do not install in areas where the temperature is colder than 40 deg rees Fahrenheit (4.
14 15 D.T amper Resist Featur e: To make your smoke alarm somewhat tamper resistant, a tamper resist featur e has been provided. Activate the tamper resist featur e by breaking off the four posts in the square holes in the trim ring (see Figure A).
17 Operating/Installation Instructions and What T o Do If The Alarm Sounds Step 4 Peak Level Memory If the CO sensor has detected a CO level of 100 PPM or higher since last reset, it will be recorded by the Peak Level Memory function. T o access the Peak Lev el Memor y press the test/reset button.
If the alarm sounds, check for fir es first. If a fire is discover ed follow these steps. Become thoroughly f amiliar with these items, and review with all family members! • Alert small childr en in the home. Children sleep ve ry sound and may not be a wakened by the sound of the smoke alarms.
Never restart the sour ce of a CO problem until it has been fixed. NEVER IGNORE THE ALARM! The CO sensor meets the alarm response time require- ments of UL standard 2034. Standard alarm times are as f ollows: At 70 PPM, the unit must alarm within 60-240 minutes.
CO inhibits the blood’ s capacity to car r y oxygen. Possible Sour ces CO can be produced when burning any fossil fuel: gaso- line, propane, natural gas, oil and wood. It can be pro- duced by any fuel-burning appliance that is malfunction- ing, improperly installed, or not ventilated correctly .
CO Safety T ips Every year have the heating system, vents, chimney and f lue inspected and cleaned by a qualified technician. Always install appliances accor ding to manufacturer’ s instructions and adhere to local building codes. Most appliances should be installed by professionals and inspected after installation.
NFP A (National Fire Protection Association) F or y our information, the National Fire Protection Association’ s Standard 72, reads as follows: Smoke alarms shall be installed outside of each separa.
Consumer Product Safety Commission The Consumer Product Safety Commission (CPSC) r ecommends the use of at least one CO Alarm per household, located near the sleeping area. NRC Ionization type smoke alarms use a ver y small amount of a radioactive element in the sensing c hamber to enable detection of visible and invisible combustion products.
Y our Kidde Combination Smoke & CO Alarm is not a substitute for property , fire, disability , life or other insur- ance of any kind. Appropriate insurance cov erage is y our responsibility . Consult your insurance ag ent. Removal of the front cov er will void the warranty .
Custom Assembled in China with U.S. and Foreign Components. Patents Pending 2505-7201-00 1394 South Third Street, Mebane, NC 27302 Consumer Hotline: 1-800-880-6788 www .
デバイスKidde KN-COSM-Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Kidde KN-COSM-Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKidde KN-COSM-Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Kidde KN-COSM-Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Kidde KN-COSM-Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Kidde KN-COSM-Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKidde KN-COSM-Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Kidde KN-COSM-Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKidde KN-COSM-Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。