Anton/BauerメーカーDIONIC 90の使用説明書/サービス説明書
ページ先へ移動 of 20
® BATTERY SYSTEM DIONIC ® 90 lithium ion Digital Battery OWNER’S MANUAL.
TABLE OF CONT ENTS IMPORTANT READ AND UNDERSTAND T HIS MANUAL BEFORE OPER ATION .................................................................... 1 INTRODUCTION .............................................................................. 2 FEATURES .
1 IMPORTANT READ AND UNDERSTAND THIS MANUAL BEFORE OPERATION The InterActive 2000 Dionic 90 battery lithium ion chemistry delivers a higher power to weight ratio than NiCd & NiMH. However, all lithium ion batteries have more sensitive char ging and discharging param eters and require longer charge times (2-5 hours).
2 INTRODUCTION The development of this new DIONIC 90 battery sy stem has been made possible through the incorporation of the pioneering InterActive technology of the Anton/Bauer Digital system with the very latest lithium ion cell formulations.
3 FEATURES 1. Microprocessor Fu el Computer - Accurately monitors the energy in the battery with programs that take into account battery age, self discharge, charge/discharge rate, operating conditions and previously experienced charge/discharge cycles.
4 CHARGING DIONIC 90 BATTERIES • DO NOT ATTEMPT TO CHARGE THIS BATTERY WITH ANY CHARGER OTHER THAN THE ANT ON/BAUER InterActive 2000 OR T SERIES CHARGERS SPECIFIED IN THIS MANUAL. • Allow the battery to reach a steady green (LifeS aver ® ) mode before using for the first time.
5 NOMINAL CHARGE TIMES FOR DIONIC 90 Charge Le v el LED Indicators 90% Flashing Green 100% Steady Green Dual 2722 (2 batteries simultaneously) 2hrs. 3hrs. InterActive 2000 Pow erCharger (Quad/Dual – 2702/2701/2700) (Quad/Dual – 2401/2400) 2 hrs. 3 hrs.
6 The DIONIC 90 features an all NEW “RealTime” LCD display providing on-the-fly remaining run time estimates in 15 minute increm ents as well as simultaneously providing remaining capacity information using the traditional “Fuel Gauge” approach.
7 -The large numbers 1, 2 or 3 indicate remaining hours under current load (only one number will display at any one time) -The pie chart numbers ( 15, 30, 45, or 60) indicate remaining minutes under current load.
8 If the SIDE BARS (only) flash AND other icons are lit and not flashing, this indicates the battery has requested to be fully charged and discharged in order to update its “learned capacity”. This “learning” should typically occur during normal equipment operation.
9 RealTime Display Indications • When the DIONIC battery is being charged remaining runtime is not displaye d. • Rem aining run time is calculated using the present available battery capacity and a constantly updated accurate measurement of the present load on the battery.
10 • W hen the battery is completely discharged the LCD will flash the 15 minute icon and the ‘RES’ bar until the battery is returned to a charger. • If the protection electronics detect a low battery voltage condition (any one cell reaches roughly 2.
11 OPERATING GUIDELINES 1. Keep batteries cool or at room temp eratures whenever poss ible. Sustained elevated temperatures are the primary reason for premature failure of lithium ion batteries: a. Charging - Charge batteries at room temperature. In warm climates keep chargers in air conditioned rooms for best performance.
12 4. Low voltage batteries can also be caused by allowing batteries to remain off the charger for extended periods causing the LCD display to be blank, indicating that the electronic circuitry has removed all load from the battery cells – including the display.
13 SERVICE In the event a DIONIC 90 battery fails to deliver acceptable performance, it must be returned to the Anton/Bauer. No ot her facility is qualified and equipped to service the InterActive 2000 DIONIC 90 ba tteries and calibrate the electronic components and sensors.
14 PRECAUTIONS 1. Do not expose this battery to high temperatures (above 50°C/120°F). This includes storage in direct sunlight , in cars in hot weather, or in close proximi ty to heating devices. This may cause electrolyte leak age, impaired p erformance and shorten ing of battery s ervice life.
15 DIONIC 90 BATTERY SPECIFICATIONS OUTPUT VOLTA GE 14.4v Nominal 12.4 ~ 16.8v Operating CA PA CITY (CELL CA PA CITY) 90 WH Nominal (6.3 AH Rated) FUSE Internal 8amp RECOMMENDED OPERA TION 15 - 50 watts 1 (MAXIMUM DISCHARGE RATE) (90 watts) 2 TYPICA L RUN-TIME @ 20w - 4 ½ hrs.
16 LIMITED WARRANTY This w arranty for the ba ttery product specif ied in this doc ume nt (“ Product”) is g iven by A nton/Bauer , Inc. (“Anton/Baue r”), 14 Progres s Driv e, Shelton, Conne cticut 06484.
17 Dangerous Goods Regulations 49C FR Parts 100-185, Air Transport Association (IATA) and the International Civil Aviation Organization (ICAO) regulations a pply to all lithium ion battery transport.
7595-0243 Rev M The power behind the best cameras capturing the best im ages in the world. sm The following are trademarks of Anton/Bauer, Inc.: ACS, ADM, All Chem, Anton/Bauer, Anton/Bauer logo and p.
デバイスAnton/Bauer DIONIC 90の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Anton/Bauer DIONIC 90をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAnton/Bauer DIONIC 90の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Anton/Bauer DIONIC 90の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Anton/Bauer DIONIC 90で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Anton/Bauer DIONIC 90を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAnton/Bauer DIONIC 90の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Anton/Bauer DIONIC 90に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAnton/Bauer DIONIC 90デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。