M M I I R R A A C C L L E E S S T T E E A A M M E E R R Models MS-150/155, MS-250/255 & MS-355 Owner ’ s Man ual P/N 1010699 Re v . B MANUF ACTURING NUMBERS: 9100420 9100426 9100428 9100430 9100.
MIRACLE STEAMER 1 P/N 1010699 Rev . B A.J. Antunes & Co. General The Miracle Steamer produces steam using plain tap water for quick heating and reconstituting of food items.
W ARNING GENERAL W ARNING. Indicates informa- tion important to the proper operation of the equipment. Failure to observe may result in damage to the equipment and/or severe bodily injury or death.
MIRACLE STEAMER 3 P/N 1010699 Rev . B A.J. Antunes & Co. In addition to the warnings and cautions in this manual, use the following guidelines for safe operation of the unit. • Read all instructions before using equipment. • For your safety , the equipment is furnished with a properly grounded cord connector .
MIRACLE STEAMER 4 P/N 1010699 Rev . B A.J. Antunes & Co. V oltage W atts Amps Hertz 120 1800 15.0 50/60 208 3300 15.9 50/60 220 3018 13.8 50/60 230 3300 14.
MIRACLE STEAMER 5 P/N 1010699 Rev . B A.J. Antunes & Co. 25" Dimensions 20-3/4" (52.7 cm) 21-3/16" (53.8 cm) 17-1 1/32" (28.8 cm) 14" (35.5 cm) 8-13/32" (21.4 cm) MS-150/155 & MS-250/255 25" 17-5/32" 14" 25" (63.
MIRACLE STEAMER 6 P/N 1010699 Rev . B A.J. Antunes & Co. Unpacking 1. Remove unit and all packing materials from ship- ping carton. 2. Open the large box. It should contain the follow- ing: • Miracle Steamer , • Handle, Handle Guard & Shoulder Bolt, ( MS-150/250 only ) • W ater Hookup Kit (MS-250 only).
MIRACLE STEAMER 7 P/N 1010699 Rev . B A.J. Antunes & Co. CAUTION All electrical connections must be in accordance with local electrical codes and any other applica- ble codes. W ARNING ELECTRICAL SHOCK HAZARD. F AILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL COULD RESUL T IN SERIOUS INJUR Y OR DEA TH.
MIRACLE STEAMER 8 P/N 1010699 Rev . B A.J. Antunes & Co. OPERA TION General When the operate button (Figure 5) is pressed, power is supplied to the water pump (MS-150/155/355) or solenoid (MS-250/255). The pump/solenoid operates and water sprays onto the heated steam generator .
to zero and an audio signal will sound at the end of the steaming cycle. 6. Remove steamed product. Programming CYC (T otal Cycle Time) refers to the total amount of cooking time set for the product. SHO (Shot Interval Time) is the time set between shots of steam during a complete cycle.
MIRACLE STEAMER 10 P/N 1010699 Rev . B A.J. Antunes & Co. READ Y UP DOWN PROGRAM ST ART/STOP POWER 1500 Figure 6. Control Programming Sequence READ Y UP DOWN PROGRAM ST ART/STOP POWER 15 READ Y UP.
MIRACLE STEAMER 11 P/N 1010699 Rev . B A.J. Antunes & Co. R E A D Y Steaming Tips • Pre-cooked pasta is easily reconstituted, and gives you a hot product without the wetness of the nor- mal “ dip ” method. • Experiment with your products and different steam- ing times – a little more or less steam could change the appearance/flavor .
MIRACLE STEAMER 12 P/N 1010699 Rev . B A.J. Antunes & Co. Daily 1. T urn the rocker switch (power on/off) to OFF . Unplug the power cord and allow the unit to cool down before proceeding. 2. Check the water quick disconnect fitting (MS-250) and all hose clamps connections for leakage.
MIRACLE STEAMER 13 P/N 1010699 Rev . B A.J. Antunes & Co. 1 1. Clean unit surface with a hot, clean, damp cloth (not dripping wet) and wipe dry . 12. Re-install all parts and fasten the generator cover . NOTE: T o ensure proper steaming characteristics, some mineral deposits must be present on generator casting.
MIRACLE STEAMER 14 P/N 1010699 Rev . B A.J. Antunes & Co. Figure 9. W ater Filters – MS-150/155 T op Water Filter Bottom W ater Filter W ater Filters – Models MS-150/155 T o prevent solids or food products from entering the water pump, the unit uses two water filters (Figure 9).
MIRACLE STEAMER 15 P/N 1010699 Rev . B A.J. Antunes & Co. Unit will not heat up. Rocker (power on/off) switch is ON. Unit heats up but will not steam. or Steam product unevenly . or Requires multiple cycles to melt cheese or otherwise prepare the product.
MIRACLE STEAMER 16 P/N 1010699 Rev . B A.J. Antunes & Co. Steam from generator is reduced compared to former operation. Unit becomes flooded or always steaming. Power ON, solenoid makes a chat- tering noise. or Unit floods overnight. Power OFF . W ater leaking in the electrical housing.
MIRACLE STEAMER 17 P/N 1010699 Rev . B A.J. Antunes & Co. Unit heats up, pump or sole- noid valve works with the momentary switch but will not steam during timer cycles. Steam coming out around top covers or sides. Programming. If Ready light does not light but the unit steams regularly , the Ready light is inoperable.
MIRACLE STEAMER 18 P/N 1010699 Rev . B A.J. Antunes & Co. REPLACEMENT P ARTS R E A D Y 64 17 15 11 18 20 74 73 36 21 66 65 6 6 7 9 10 12 13 24 62 37 35 70 16 57 57 53 53 53 42 41 75 89 81 88 3 81 .
MIRACLE STEAMER 19 P/N 1010699 Rev . B A.J. Antunes & Co. 1 0010159 Filter Assy ., W ater T ank (MS-150) 1 2 4050125 Relay 1 3 0010584 Inlet Hose Assy . (MS-250) 1 4 001 1 1 14 Pump/T ube Assy ., 24V (MS-150) 1 5 001 1 123 Solenoid V alve Assy . (MS-250) 1 6 001 1289 T op Cover Assy .
MIRACLE STEAMER 20 P/N 1010699 Rev . B A.J. Antunes & Co. INSET B (Model MS 150) REA DY B 43 31 32 33 23 54 28 46 READ Y 72 69 48 47 67 49 71 51 60 56 2 68 19 54 26 58 59 27 A 43 1 9 39 55 34 INSET C (Model MS 150) INSET A (Model MS 150) A C C 4 49 43 B C C 77 78 76 61 46 37 MS-150/155/250/255 NOTE: Refer to parts list on page 19.
READ Y 22 55 INSET A (Model MS 250) READ Y 72 48 47 67 49 71 61 60 56 66 14 69 19 54 26 58 59 27 29 32 33 23 54 28 45 30 5 INSET B (Model MS 250) A A 55 45 37 2 MIRACLE STEAMER 21 P/N 1010699 Rev . B A.J. Antunes & Co. NOTE: Refer to parts list on page 19.
MIRACLE STEAMER 22 P/N 1010699 Rev . B A.J. Antunes & Co. 1 001 1314 Steam V ent Assy . 1 2 001 1408 T op Cover Assy . (Incl. #73-77) 1 3 001 1413 Liner Assy . (Incl. #65, 69, 72) 1 4 001 1414 Drawer Assy . (Incl. #64-71) 1 5 001 1416 Main Housing Assy .
MIRACLE STEAMER 23 P/N 1010699 Rev . B A.J. Antunes & Co. INSET C (Model MS 355) C C 49 49 READY 32 48 42 57 50 51 45 44 62 24 58 47 43 28 49 READ Y AD D WATER B INSET A (Model MS 355) 59 51 B C C.
MIRACLE STEAMER 24 P/N 1010699 Rev . B A.J. Antunes & Co. R EA D Y A DD ADD WA TE R TER 21 53 27 26 25 47 47 46 46 46 10 19 74 75 77 76 73 2 1 11 18 5 52 16 55 56 9 8 65 64 69 65 69 72 68 67 66 70 71 61 7 4 3 6 13 25 30 MS-355 NOTE: Refer to parts list on page 22.
MIRACLE STEAMER 25 P/N 1010699 Rev . B A.J. Antunes & Co. REPLACEMENT P ARTS (continued) Item Part Description Qty . No. 1 0503615 Bracket, Manifold 1 2 2030125 T ubing, 1/4" I.
MIRACLE STEAMER 26 P/N 1010699 Rev . B A.J. Antunes & Co. WIRING DIAGRAMS VIO MOMENT ARY SWITCH THERMOCOUPLE S.S. RELA Y CONTROL BO ARD T5 T2 T1 T3 T7 T2 T6 2 1 3+ 4– YEL RED BLU BLU BLK HEA TER.
1025 W . National Avenue • Addison, Illinois 60101 T elephone (630) 543-8650 • F AX (630) 543-0359 • 1-800-253-2991 www .ajantunes.com LIMITED W ARRANTY Equipment manufactured by Roundup Food Equipment Division of A.J. Antunes & Co. has been constructed of the finest materials available and manufactured to high quality standards.
デバイスAntunes, AJ MS-250/255の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Antunes, AJ MS-250/255をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAntunes, AJ MS-250/255の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Antunes, AJ MS-250/255の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Antunes, AJ MS-250/255で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Antunes, AJ MS-250/255を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAntunes, AJ MS-250/255の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Antunes, AJ MS-250/255に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAntunes, AJ MS-250/255デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。