WA TER FIL TRA TION SY STEM UF-420/440 Series Owner ’ s Man ual P/N 1010827 Rev .D 04/06 MANUF ACTURING NUMBERS: 9700440 9700442 9700443 9700450 9700452 9700453.
UF SERIES W A TER FIL TRA TION SYSTEM 2 P/N 1010827 Rev . D 04/06 General Antunes Filtration T echnologies, a Division of A.J. Antunes & Company , has partnered with compa- nies from around the globe to produce the UF-Series water filtration systems.
UF SERIES W A TER FIL TRA TION SYSTEM 3 P/N 1010827 Rev . D 04/06 Purchased From: Date of Purchase: Model No.: Serial No.: Mfg. No.: Service/T echnical Assistance If you experience any problems with t.
UF SERIES W A TER FIL TRA TION SYSTEM 4 P/N 1010827 Rev . D 04/06 Protect from becoming dry If the membrane dries out, irreversible damage to the membrane may result.
UF SERIES W A TER FIL TRA TION SYSTEM 5 P/N 1010827 Rev . D 04/06 Inlet W ater Pressure (psi) Inlet T urbidity (NTU) Required Additional Equipment Installed W ater Use (Gallons Per Day) Flush Program .
UF SERIES W A TER FIL TRA TION SYSTEM 6 P/N 1010827 Rev . D 04/06 SPECIFICA TIONS Electrical Ratings CAUTION All electrical connections must be in accordance with local electrical codes and any other applicable codes. W ARNING ELECTRICAL SHOCK HAZARD.
UF SERIES W A TER FIL TRA TION SYSTEM 7 P/N 1010827 Rev . D 04/06 Dimensions Unit A Width (inches) B Depth (inches) C Height (inches) Operating Weight (w/water) (lbs) UF-420 6-1/16 14-7/8 33-7/8 30 UF-440 6-1/16 14-27/32 53-17/32 51 A B C Figure 1.
UF SERIES W A TER FIL TRA TION SYSTEM 8 P/N 1010827 Rev . D 04/06 Unpacking 1. Remove the system and all packing materials from the shipping carton. 2. Remove all packing materials and protective cov- erings from the system 3. Remove the information packet.
UF SERIES W A TER FIL TRA TION SYSTEM 9 P/N 1010827 Rev . D 04/06 INST ALLA TION (continued) PERMEA TE LINE PLUMBING T o ensure the highest quality and safest water , it is recommended that a check valve (to prevent backflow) is installed in the water line after the permeate connec- tion.
UF SERIES W A TER FIL TRA TION SYSTEM 10 P/N 1010827 Rev . D 04/06 CAUTION Ingesting the protective solution may cause irrita- tion of the gastrointestinal tract, colic, diarrhea, or other similar symptoms 1. Plug the power cord into the appropriate electrical outlet.
UF SERIES W A TER FIL TRA TION SYSTEM 1 1 P/N 1010827 Rev . D 04/06 Figure 4. Proper Draining 2” (5.1 cm) minimum 2” (5.1 cm) minimum Floor Drain Secure End Drain Line from System Drain Line from System Secure End Drain Standpipe INST ALLA TION (continued) OPERA TION Figure 5.
UF SERIES W A TER FIL TRA TION SYSTEM 12 P/N 1010827 Rev . D 04/06 OPERA TION (continued) Programming T imer During Startup NOTE: Once the UF unit is powered up, the LED display cycles through the default or current settings: Flush Duration (Fd) and its setting will be followed by Flush Interval (Fi) and its settings.
UF SERIES W A TER FIL TRA TION SYSTEM 13 P/N 1010827 Rev . D 04/06 OPERA TION (continued) START START TO SET FD - FLUSH DURA TION MODE 1. Press and hold the Start button for four seconds. Release button, LED will display Fd . 2. When Fd is displayed (Figure 12), press and release the Start button to view the current setting 3.
UF SERIES W A TER FIL TRA TION SYSTEM 14 P/N 1010827 Rev . D 04/06 START Figure 14. Manual Flush MAINTENANCE Changing the Cartridges While the filtration system is designed for long life, eventually the cartridges will need to be replaced. 1. Open the faucet or tap closest downstream to the filtration system.
UF SERIES W A TER FIL TRA TION SYSTEM 15 P/N 1010827 Rev . D 04/06 TROUBLESHOOTING Problem Possible Cause Corrective Action Unit does not have power . The power cord is not correctly plugged in. Plug power cord in correctly . The Control Display is blank.
UF SERIES W A TER FIL TRA TION SYSTEM 16 P/N 1010827 Rev . D 04/06 REPLACEMENT P ARTS UF-420/440 1 7000432 T imer , 120V (For Mfg. #s 1 9700440 & 9700450) 7000433 T imer , 230V (For Mfg.
UF SERIES W A TER FIL TRA TION SYSTEM 17 P/N 1010827 Rev . D 04/06 REPLACEMENT P ARTS UF-420/440 (continued) 14 6 13 5 26 1 2 15 17 17 25 23 19 20 21 22 28 3 4 8 18 24 16 16 18 7 32 29 30 31 9 10 29 2.
LIMITED W ARRANTY Equipment manufactured by Antunes Filtration T echnologies, Division of A.J. Antunes & Co. has been constructed of the finest materials available and manufactured to high quality standards.
デバイスAntunes, AJ UF-420/440の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Antunes, AJ UF-420/440をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAntunes, AJ UF-420/440の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Antunes, AJ UF-420/440の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Antunes, AJ UF-420/440で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Antunes, AJ UF-420/440を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAntunes, AJ UF-420/440の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Antunes, AJ UF-420/440に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAntunes, AJ UF-420/440デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。