©Eastman Kodak Company, 2004 V2CS August, 20 04 KODAK VISION2 Color Negative Control Strips Process ECN-2 Technical Data and Crossover Information.
2 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Note: While the data presented are typical of production coatings, they do not represent standards which must be met by Kod ak. Varying storage, expo sure, and processin g conditions will affect results.
KODAK VISION2 Color Negative Control Str ips, Technical Data and Crossover Informa tion 3 KODAK VISION2 Color Negative Control Strips Introduction KODAK VISION2 Color Negati ve Control Strips (Figure 1) are intended for the control of Proces s ECN- 2 us ing the procedures described in KODAK Pub lication No.
4 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Control Strip Log Exposure Range The graphs in Figure 2 and Figure 3 demonstrate the differences between the .
KODAK VISION2 Color Negative Control St rips, Technical Data and Crossover Info rmation 5 Figure 2 ECN-2 Control Strip Exposed on KODAK VISION 200T Color Negative Film 5274 0.
6 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Figure 3 ECN-2 Control Strip Exposed on KODAK VISION2 200T Color Negative Film 5217 Exposure: 1/50 sec Process: ECN-2 Densitometry: Status M 0.0 1.0 2.0 3.0 -4.
KODAK VISION2 Color Negative Control St rips, Technical Data and Crossover Info rmation 7 Effects of Mechanical and Chemical Variations Figures 4 th rough 13 illustrate some of the maj or photographic.
8 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Developer Mech anical Factors Figure 4 Effects of Tim e and Temperature Varia tions —VISION2 Control Strips.
KODAK VISION2 Color Negative Control St rips, Technical Data and Crossover Info rmation 9 Developer Chemical Fac tors Figure 5 Effects of pH an d CD- 3 Variations —VISION2 Control Strips versus VISION C ont rol Strips in Process ECN-2 Developer HD-LD D-min LD 0000 HD MD 5274 5217 CD-3 5.
10 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Developer Chemical Fac tors Figure 6 Effects of NaBr and AF- 2000 Variations —VISION2 Control Strips versus VISION C ont rol Strips in Pr ocess ECN-2 Developer MD HD 0000 LD D-Min HD-LD 5274 5217 AF-2000 7.
KODAK VISION2 Color Negative Control St rips, Technical Data and Crossover Info rmation 11 Developer Chemical Fac tors Figure 7 Ef fects of Na 2 SO 3 and Under and Over Replenishment Variation s —VI.
12 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Developer Chemical Fac tors Figure 8 Effects of PB-C1 and PB-2 Prebath Contaminat ion —VISION2 Control Strips versus VISION C ont rol Strips in Pr ocess ECN-2 Developer MD HD 0000 LD D-Min HD-LD 5274 5217 Prebath PB-2 200.
KODAK VISION2 Color Negative Control St rips, Technical Data and Crossover Info rmation 13 Developer Chemical Fac tors Figure 9 Effects of CD-2 for CD- 3 an d Sto p Bath Co nta m ina tio n —VISION2 Control Strips versus VISION C ont rol Strips in Process ECN-2 Developer HD-LD D-min LD 0000 HD MD .
14 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Developer Chemical Fac tors Figure 10 Effects of Bleach Contaminatio n —VISION2 Control Strips versus VISION C ont rol Strips in Pr ocess ECN-2 Developer HD-LD D-Min LD 0000 HD MD .
KODAK VISION2 Color Negative Control St rips, Technical Data and Crossover Info rmation 15 Developer Chemical Fac tors Figure 11 Effects of F-34a Fixer and Final Rinse Contamination —VISION2 Control.
16 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Developer Chemical Fac tors Figure 12 Eff ects of KI Co ntamination and Water Dilut ion —VISION2 Control Strips versus VISION C ont rol Strips in Pr ocess ECN-2 Developer HD-LD D-min LD 0000 HD MD .
KODAK VISION2 Color Negative Control St rips, Technical Data and Crossover Info rmation 17 Developer Chemical Fac tors Figure 13 Effects of Bacterial Na 2 S and Na 2 CO 3 Contamination —VISION2 Control Strips versus VISION C ont rol Strips in Process ECN-2 Developer 5274 5217 Na CO 23 g/L g/L 15.
18 KODAK VISION2 Color Negativ e Control Strips , Technical D ata and Crossover Information Control-Strip Crossover Important: During the inventory crosso ver from the old VISION Control St rips to the new VISION2 Con trol Strips, every effort should be taken in your operations to avoid switching back and forth.
KODAK VISION2 Color Negative Control St rips, Technical Data and Crossover Info rmation 19 Figure 14 Control-Stri p Crossover for Process ECN-2 F009_0143EC 10 12 11 12 12 12 12 12 12 12 11 11 11 12 10 10 12 1pm 1pm 1pm 4pm 1pm 8am 4pm 1pm 4am 4pm 1pm 7121 # 1 ECN-2 W E N 0.
Revised 5-05 Printed in U.S.A. KODAK VISION2 Color Ne gative Cont rol Strips KODAK VISION2 Color Negative Control Strips KODAK Publication No. V2CS MORE INFORMATION Outside the United States and Canada, please contact your Kodak representative. You can also visi t our web site at www.
デバイスKodak V2CSの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Kodak V2CSをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはKodak V2CSの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Kodak V2CSの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Kodak V2CSで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Kodak V2CSを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はKodak V2CSの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Kodak V2CSに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちKodak V2CSデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。