WS-7034U Wireless 433 MHz Temperature Station Instruction Manual.
2 TABLE OF CONTENTS Topic Page Quick Setup 3-5 Inventory of Contents 6-7 Detailed Setup Guide Battery Installation 8 Setting the Time 9-10 Selecting Units of Measurement 10 Features Minimum and Maximu.
3 QUICK SETUP Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. Have the indoor temperature st ation and remote tem perature sensor 3 to 5 feet apart. 2. Batteries should be out of both units for 10 minutes. 3. Place the batteries into the remote temperature sensor first then into the indoor temperature st ation.
4 In this time the indoor temperature station and remot e temperature sensor will start to talk to each other and the display will show both the indoor temperature and an outdoor temperature. If the indoor temperat ure station does not display both t emperatures after t he 10 minutes please ret ry the set up as stated above.
5 of resistance. Your distance plus resistance should not exceed 80 ft. in a straight line. NOTE: Fog and mist will not harm your remote tem perature sensor but direct rain must be avoi ded. To complete the set up of your i ndoor temperature station after the 10 m inutes have passed please follow the steps on pages 8-9.
6 Figure 2 Figure 1 Holder INVENTORY OF CONTENTS 1. The indoor temperature station (Figure 1) 2. The remote temperature sensor (TX6U) and mounting bracket. (Figure 2) 3. 3 each, 1/2” Philips screws. 4. One strip of double sided adhesive tape. 5. Instruction Manual and Warranty Card.
7 ADDITIONAL EQUIPMENT (not included) 1. 1 Philips screwdriver. 2. 2 Fresh AAA Alkaline batteries. 3. 2 Fresh AA Alkaline batteries.
8 Battery Cover DETAILED SETUP GUIDE Battery Installation 1. Install 2 AA batteries in the remote temperature sensor. Make sure they do not spring free, or start-up problems may occur. 2. Install 2 AAA batteries in the indoor temperature station. Do not press any buttons for at least ten minutes.
9 1. Press and hold the “ SET” button for 5 second, “12h” will appear in the TIME LCD. 2. Press and release the “ MIN/MAX” button to select either 12h time (am/pm) or 24h time 3. Press and release the “ SET” button 2 times, the hour will flash in the upper left corner.
10 Selecting Units of Measurement 1. Press and hold the “SET” button for 5 second until “12h” or “24h” appears in the TIME LCD. 2. Press and release the “ SET” button again, “ ° F” will appear in the TIME LCD. 3. Press and release the “ MIN/MAX” button to shift between ° F and ° C.
11 FEATURES Minimum and Maximum Temperatures 1. Press and release the “MIN/MAX” button, “MIN” appears next to the indoor and remote temperatures. 2. The recorded minimum temperature is displayed. The time of the minimum outdoor temperature will also flash.
12 Resetting Min and Max Tempe r atur e s To reset both the mi ni mum a n d ma xi mum temperatures—press and hold the “RESET/+” button for 4 seconds.
13 Adding Additional Remote Temperature Sensors (optional) The WS-7034U is able to receive signals from 3 different remote temperature sensors. Following are some brief instructions for the basic set-up of remote temperature sensor units with the WS-7034U.
14 indoor temperature station and do not press any buttons for ten minutes. Transmission problems will arise if this is not done correctly. To view the temperature of a different remote temperature sensor unit, press and release the “SET/CH” button.
15 MOUNTING Note: To achieve a true temperature reading, avoid mounting in direct sunlight. We recommend that you mount the remote temperature sensor on a North-facing wall. The sending range is 80ft; obstacles such as walls, concrete, and large metal objects will reduce the range.
16 Indoor Temperature Station The indoor temperature station comes with the table stand already mounted. If you wish to use the table-stand all that is required is to place the indoor temperature station in an appropriate location. 1. To wall mount the indoor temperature station first remove the table stand.
17 TROUBLESHOOTING NOTE: For problems not solved, please contact La Crosse Technology via e-mail or phone, or visit our website, www.lacrossetechnology.com Problem: The LCD is faint Solution: Replace batteries Problem: No outdoor temperature is displayed.
18 Solution: Each temperature sensor is manufactured to be accurate to within 1 degree plus or minus and under normal conditions, so two sensors could be as much as 2 degrees different. However, the difference can be exaggerated further because the sensors are designed for different working environments.
19 • Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units. • Clean displays and units with a soft, damp cloth. Do not use solvents or scouring agents; they may mark the displays and casings. • Do not submerge in water.
20 SPECIFICATIONS Transmitting Frequency 433MHz Measuring Temperatures Indoor Temperature Station 32 ° F to 156.2 ° F with 0.2 ° F resolution. (0 ° C to 69.0 ° C with 0.1 ° C resolution). Remote Temperature Sensor -21.8 ° F to 156.2 ° F with 0.
21 Indoor Temperature Station 2 x AAA, 1.5V Dimensions: (L x W x H) Indoor Temperature Station 2.36 x .88 x 5.90 in. (excluding table stand) (60 x 22.5 x 150 mm). Remote Temperature Sensor 2.32 x 0.86 x 2.55 in. (59 x 22 x 65 mm). Battery life Approximately 1 year.
22 authorized service center . The original dated bill of sale must be presented upon request as proof of purchase to La Crosse Technology, Ltd or La Crosse Technology, Ltd’s aut horized service center.
23 the lack of reasonable and necessary maintenance); (2) damage occurring during shipment (claims must be presented to the carrier); (3) damage to, or deterioration of, any accessory or decorativ e s.
24 This warranty giv es you s pecific legal rights. You may also have other rights spec ific to y our State. Some States do no allow the exclusion of consequential or incidental dam ages therefore the above exclusion of limitation may not apply to you.
25 interference, and (2) th is device must accept any interference received, including interference that may cause undesir e d operation. Freq. 433.92 MHz La Crosse Technology Made in China WS-7034U FCC ID: OMO-01RX (Receiver), OMO-01TX (sensor) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.
デバイスLa Crosse Technology WS-7034Uの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
La Crosse Technology WS-7034Uをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLa Crosse Technology WS-7034Uの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。La Crosse Technology WS-7034Uの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。La Crosse Technology WS-7034Uで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
La Crosse Technology WS-7034Uを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLa Crosse Technology WS-7034Uの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、La Crosse Technology WS-7034Uに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLa Crosse Technology WS-7034Uデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。