1 WS-9014U Wireless 433 MHz Temperature Station Instruction Manual.
2 TABLE OF CONTENTS Topic Page Inventory of Contents 3 Quick Setup 4-8 Detailed Setup Guide Battery Installation 9-10 Setting the Time 11-12 Selecting Units of Measurement 12-13 Features Minimum and M.
3 INVENTORY OF CONTENTS 1. The indoor temperature station (Figure 1) 2. The remote temperature sensor (TX6U) and mounting bracket. (Figure 2) 3. 3 each, 1/2” Philips screws. 4. One strip of double sided adhesive tape. 5. Instruction Manual and Warranty Card.
4 QUICK SETUP Hint: Use good quality Alkaline Batteries and avoid rechargeable batteries. 1. Have the indoor temperature station and remote temperature sensor 3 to 5 feet apart. 2. Batteries shoul d be out of both units for 10 m inutes. 3. Place the batteries into the remote temperature sensor first then into the indoor temperat ure station.
5 In this time the indoor temperature station and rem ote tem perature sensor will start to talk to each other and the display will show both the indoor temperature and an out door temperat ure. If the indoor tem perature station does not display bot h temperat ures after the 10 minutes pl ease retry the set up as stated above.
6 of resistance. Your distance plus resistance should not exceed 80 ft. in a straight line. NOTE: Fog and mist will not harm your remote t emperature sensor but direct rain must be avoided. To complet e the set up of your indoor temperature station after the 10 minutes have passed please follow the steps below.
7 b. When you have your choice shown on the display press and release the “SET” button once. 2. Degree Fahrenh eit will now sho w . a. To change between Fahrenheit and Celsius, press and release the “MIN/MAX” button. b. When you have your choice shown on the display press and release the “SET” button once.
8 PM hours. During the AM hours this area will be blank. b. When the correct hour is shown, press and release the “SET” button once. 4. A minute will now be flashin g . a. Press and release the “MIN/MAX” button u ntil the correct minutes are displayed.
9 1. Remove the mounting bracket. 2. Remove battery cover 3. Observing the correct polarity, install 2 AA batteries—make sure they do not spring free, or start-up problems may occur. Replace cover. B. INDOOR TEMPERATURE STATION Note: After the batteries are installed, DO NOT press any buttons.
10 1. Remove the battery cover on the backside. To do this, push up and pull out. 2. Observing the correct polarity, install 2 AA batteries. 3. Replace battery cover. 4. Wait 10 minutes or until both the indoor and outdoor temperatures are shown on the indoor temperature station.
11 II. TIME A. SETTING THE TIME 1. Press and hold the “ SET” button for 5 second, “12h” will appear in the TIME LCD. 2. Press and release the “ MIN/MAX” button to select either 12h time (am/pm) or 24h time 3. Press and release the “ SET” button 2 times, the hour will flash in the upper left corner.
12 Note: When in 12h mode, there is only a “PM” display, which appears under “TIME.” If there is no display here it is AM. Make sure you set the time accordingly. III. UNITS OF TEMPERATURE MEASURE A. SELECTING UNITS OF MEASUREMENT 1. Press and hold the “SET” button for 5 second until “12h” or “24h” appears in the TIME LCD.
13 IV. FEATURES A. MINIMUM AND MAX IMUM TEMPERATURES 1. Press and release the “ MIN/MAX” button, “MIN” appears in the temperature LCD’s and the recorded minimum temperat ure s a re display ed. 2. Press and release the “ MIN/MAX” button to toggle to the maximum temperatures.
14 1. The WS-9014U is able to receive signals from 3 different remote temperature sensors. Following are some brief instructions for the basic set-up of remote temperature sensor units with the WS-9014U. These extra sensors can be purchased through the same dealer as this unit, or by contacting La Crosse Technology directly.
15 the total time for set-up exceeds 6 minutes. 2. It is necessary to remove the batteries from all units currently in operation. 3. Remove the battery covers to all remote temperature sensor units. 4. Place all remote temperature sens or units in a numeric sequential order.
16 from one “boxed” number to the next should be observed in the OUTDOOR LCD. 2. To view the Mi ni mum/ Ma xi mum temperature: first select from which remote temperature sensor to read data (indicated by the “boxed” number).
17 both units in their desired location before permanently mounting. A. REMOTE TEMPERATURE SENSOR 1. Remove the mounting bracket from the remote temperature sensor 2. Mount using either screws or adhesive tape. 3. Reattach the remote temperature sensor to the mounting bracket.
18 temperature station onto the screw using the hanging hole on the backside. Gently pull the indoor temperature station down to lock the screw into place. TROUBLESHOOTING NOTE: For problems not solved, please contact La Crosse Technology via e-mail or phone, or visit our website, www.
19 4) Place remote temperature sensor and indoor temperature station in position so the straight-line signal is not passing through more than two or three walls.
20 ends of a range, making it harder to compare different ranges with different curves. Under non-laboratory conditions, it is difficult to compensate for the above factors and obtain an accurate comparison. MAINTENANCE AND CARE INSTRUCTIONS • Extreme temperatures, vibration, and shock should be avoided to prevent damage to the units.
21 SPECIFICATIONS Transmitting Frequency 433MHz Measuring Temperatures Indoor Temperature Station: Indoor 32 ° F to 156.2 ° F with 0.2 ° F resolution. (0 ° C to 69.0 ° C with 0.1 ° C resolution) Indoor Temperature Station: Outdoor -21.8 ° F to 156.
22 Indoor Temperature Station 2 x AAA, 1.5V Dimensions: (L x W x H) Indoor Temperature Station 2.36 x 0.88 x 5.90 in. Remote Temperature Sensor 1.57 x 0.85 x 5.00 in. Battery life Approximately 1 year WARRANTY INFORMATION La Crosse Technology provides a 1-year warr anty on this weather station.
23 This warranty does not cover any defects r esulting from im proper use, unauthorized repair s, faulty batteries, or the weather stations inability to receive a signal due to any source of interference.
24 Phone: 608.782.1610 Fax: 608.796.1020 e-mail: support@lacrossetechnology.com (warranty work) sales@lacrossetechnology.com (information on other products) web: www.lacross ete chnology.com FCC DISCLAIMER This device complies with part 15 of the FCC rules.
25 FCC ID: OMO-01RX (Receiver), OMO-01TX (tr ansm itter) THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: 1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND 2. THIS DEVICE MUST ACCEPT INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.
デバイスLa Crosse Technology WS-9014Uの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
La Crosse Technology WS-9014Uをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLa Crosse Technology WS-9014Uの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。La Crosse Technology WS-9014Uの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。La Crosse Technology WS-9014Uで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
La Crosse Technology WS-9014Uを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLa Crosse Technology WS-9014Uの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、La Crosse Technology WS-9014Uに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLa Crosse Technology WS-9014Uデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。