La Crosse TechnologyメーカーWT-62Uの使用説明書/サービス説明書
ページ先へ移動 of 26
1 WT-62U Digital Window Thermometer Features: • Clear functional design • Easy to read outdoor temperature from i ndoors • Maximum and minimum values with auto reset • Easy to mount • Weather resistant Specifications: Measuring range: -22 ºF to +122 ºF Resolution: 0.
2 NOTE: The thermometer will automatically time out and return to the normal di splay mode after approximately 30 seconds. Installation: 1. Select your location for mounting in an area that is easy to view. NOTE: The design of the thermometer is such that the display will appear darker when looki ng at an upward angle at the displa y.
3 W AR R AN T Y I N FO R M AT I ON La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing d efects in materials and wor kmans hip.
WS-9013U Wireless 433 MHz Radio-controlled Weather Station Instruction Manual.
2 Topic Page Inventory of Contents/Additional Equipment 3 About WWVB 4 Quick Set-Up Guide 5 Detailed Set-Up Guide Battery Installation 6-7 Program Mode Programming Sequence 7 Function Keys 8 12/24 Hou.
3 INVENTORY OF CONTENTS 1. The weather station (Figure 1). 2. One TX6U remote tem perature sensor with m ounting bracket (Figure 2). 3. Three each, ½” Philips screws. 4. One strip double-sided adhesive t ape. 5. Instruction Manual and Warranty Card.
4 ABOUT WWVB (Radio Controlled Time) The NIST (National Institute of Sta ndards and Technology—Time and Frequency Division) WW VB radio station is located in Ft. Collins, Colo rado and transmits the exact time signal conti nuously throughout the Unite d States at 60 kHz.
5 QUICK SET-UP GUIDE Hint: Use good quality Alkaline Batteri es and avoid rechargeable batteries. 1. Have the indoor weather station and rem ote tem perature sensor 3 to 5 apart. 2. Batteries should be out o f b oth units. 3. Place the batteries into the remote temperature sensor first then into the indoor weather station.
6 DETAILED SET-UP GUIDE I. BATTERY INSTALLATION A. REMOTE TEMPERATURE SENSOR 1. Rem ove the mounting bracket. The bracket snaps on and off easily. 2. Rem ove the battery cover, by sl iding the cover down. 3. Observing th e correct polarity install 2 AA batteries.
7 PROGRAM MODE Programming Note: If 30 seconds are allowed to pass or ei ther the IN or the OUT bu tton is pressed durin g programmin g modes, the unit will set the last information entere d—the display will stop flashing and return to normal time-date readings.
8 II. FUNCTION KEYS The function keys are operated by pressing the key corresponding to the operat ion that you want to perform . II. 12 OR 24 HOUR TIME SETTING 1. Press and hold the “SET” button for 3 seconds or until “12 h” flashes in the DATE LCD.
9 4. Select your appropriate time zone using the “CH” button. During selection of the Tim e Zone, the 3 letter abbreviations for the time zones found in North America will flash across the top of the TIME LCD. Observe the chart below, showing the corresponding abbreviations, time zones, and codes.
10 6. Press and release the “SET” button to confirm and advance t o the Time sett ing mode. V. TIME There are two methods by whi ch the time can be set : A) Automatically via WWVB reception or B) Manually. A. WWVB (Remote Control Time) This met hod requires you to do nothing except wai t for the signal to be received and to select a time zone.
11 5. Press and release the “SET” butto n to confirm the hour setting and to advance to the m inute setting m ode. 6. The minute digits should be flashing. Press and rel ease the "CH” button to change the minutes—i ncreasing the minut es by increments of 1 w ith each press of the “CH” butt on.
12 5. The numeric-month will be flashing in the D ATE LCD. Press and release the “CH” button to select to the cu rrent month. 6. Press and release the “SET” button to confirm the numeric- month, and to ente r the numeric-day setting mode. 7. The numeric-day will be flashing, p ress and release the “CH” button to select the current day .
13 VIII. SETTING THE LCD CONTRAST 1. Press and hold the “SET” button for 3 seconds or until “12h” or “24h” flashes in the DATE LCD. 2. Press and release the “SET” button 10 more times to reach the LCD contrast setting m ode. 3. The default setting—“Lcd 5 ” will flash in the DATE LCD.
14 FEATURES OF THE WS-9013U I. INDOOR TEMPERATURE The current indoor is displayed in the INDOOR LCD and is updat ed every 10 seconds. II. OUTDOOR TEMPERATURE The outdoor temperature is viewed i n the OUTDOOR LCD. The outdoor temperature is updated every five minut es.
15 III. MINIMUM AND MAXIMUM TEMPERATURE RECORDS The WS-9013U keeps a record of the MINIMUM and MAXIMUM temperature and the time and date of their occurrence—for both the indoor and outdoor modes. A. VIEWING THE INDOOR TEMPERATURE RECORDS 1. Press the “IN” button once.
16 C. RESETTING THE MIMIMUM AND MAXIMUM RECORDS 1. All the indoor records (minim um and maximum) will be reset after the “IN” button is pressed and held for 5 seconds. 2. All the outdoor records (min imum and m aximum) will be reset after the “OUT” button is pressed and held for 5 seconds.
17 3. Place all remote temperature sensor units in a numeric sequential order. 4. In sequential order, install ba tteries (follow the same battery installation pr ocedures seen in section I. A) of th e Detailed Set-Up Guide). 5. Install batteri es into the indoor weather station.
18 MOUNTING Note: Before permanently mount ing ensure that the indoor weather station is able to receive WWVB signals from th e desired location. Also, extreme and sudden changes in temperature w ill decrease the accuracy of the indoor weather station.
19 ensure a secure hold. The mounting surface should be smooth and flat . 2) Remove the protective stri p from one side of the tape. Adhere the tape to the desi gnated area on t he back of the mounting bracket . 3) Remove the protective strip from t he other side of the tape.
20 TROUBLESHOOTING Problem: No reception of WWVB time signal. Solution: 1) Wait overnight for signal. 2) Be sure indoor weather station is at least 6 feet from any electrical devices such as televisi ons, computers or other radio-cont rolled clocks.
21 • O pening the casings inv alidates the warranty. Do not try to repair the unit. Contact La Crosse Technology for repairs. SPECIFICATIONS Temperature measuring range: Indoor: 32 ° F to 139.8 ° F with 0.2 ° F resolutio n . (0 ° C to 59.9 ° C with 0.
22 WA RRA NTY INFORMATION La Crosse Technology, Ltd provides a 1-y ear limited w arranty on this product against manufacturing defects in ma terials and workmanship. This limited warranty begins on the original dat e of purchase, is valid only on products purchased and used in North America and only to the original purchaser of this product.
23 ASSOCIATED WITH THE OPERAT ION OR MALFUNCTION OF THIS PRODUCT. THIS PRODUCT IS NOT T O BE USED FOR MEDICAL PURPOSES OR FOR PUBLIC INFORMATION. THIS PRO DUCT IS NOT A T OY. KEEP OUT OF CHILDREN’S REACH. This warranty gives y ou specific legal rights.
デバイスLa Crosse Technology WT-62Uの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
La Crosse Technology WT-62Uをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLa Crosse Technology WT-62Uの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。La Crosse Technology WT-62Uの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。La Crosse Technology WT-62Uで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
La Crosse Technology WT-62Uを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLa Crosse Technology WT-62Uの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、La Crosse Technology WT-62Uに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLa Crosse Technology WT-62Uデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。