CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM APC Symmetra LX GUIDE SPECIFICATIONS FOR 4kVA-16kVA Uninterruptible Power System PART 1 - GENERAL 1.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM E. The UPS and associated equipment shall opera te in conjunction with a primary power supply and an output distribution s ystem to provide quality uninterrupted power for mission critical, electronic equipment load.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM F. External Service Bypass Panel (SBP): Th e maintenance service bypass cabinet shall provide power to.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 2.2 SYSTEM CHARACTERISTICS A. System Capacity: The syste m shall be rated for .8 Pf output in the f ollowing frame sizes: 1. 8 kVA/ 6.4kW - Can be configured with up to (3), 3.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 1) >130% for 4 seconds 2) 105% continuous 3) <130% Continuous at N+1 b. Bypass Operation: 1) 100A continuous 8. System AC-AC Efficiency: >90% at 100% load 10.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 2. In cases where the source voltage to the UPS is nominal and the applied UPS load is equal to or les.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 2.7 AUTOMATIC BYPASS A. As part of the UPS, a system automatic bypass switch shall be provided.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM B. Metered Data: The following metered data, shall be available on the alphanum eric display: 1. Year, Month, Day , Hour, Minute, Second of occurring events 2.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 15. Need Battery Replacement 16. The Redundant Intelligence Module is in control 17. UPS Fault 18. On Battery 19. Shutdown or unable to transfer to battery due to overload 20.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM K. Controls: The following controls or prog ramming functions shall be accomplished by use of the display unit. Pushbutton membra ne switches shall facilitate these operations.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM B. The battery jars housed within each removable battery module shall be of the Valve Regulated Lead Acid (VRLA) type.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 1. The UPS, in conjunction with a network interface card, shall be capable of gracefully shutting down one or more operating systems during when the UPS is on reserve mode.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 1. Inspect equipment for signs of damage. 2. Verify installation per manufacturer s instructions. 3. Inspect cabinets for foreign objects. 4. Inspect Battery Units.
CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM CSI SECTION 16611 STATIC UNINTERR UPTIBLE SYSTEM 8. Verify proper charger operation. 9. Document, sign, and date all test results.
デバイスAPC LXの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
APC LXをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはAPC LXの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。APC LXの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。APC LXで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
APC LXを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はAPC LXの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、APC LXに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちAPC LXデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。