NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 41" Wood Burning Fireplaces P/N 504,217M REV. D 12/2003 LA41CF LA41TCF MODELS WH Report No. J20017261-231 ELITE SERIES This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • millboard • dry wall • plywood • etc. PRECAUTIONS Note: These fireplace systems are not difficult to install.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT. INSULATION OR VAPOR BARRIERS, IF USED, MUST FIRST BE COVERED WITH GYPSUM BOARD, PLYWOOD, PARTICLE BOARD OR OTHER MATERIAL TO ASSURE INSULATION AND VAPOR BARRIERS REMAIN IN PLACE.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 DO NOT permanently place furniture or other items such as decorative pillows within 60" of the fireplace front face. ASSEMBLY STEPS Note: The following steps represent the normal sequence of installation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 FIREPLACE SPECIFICATIONS Figure 10 Figure 8 Figure 9 Blocking Metal Safety Strips Note: Safety strips are not required when fire- place rests on a noncombustible surface. Note: Install the hearth extension only as illus- trated.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Note: The framed depth, 28 ¹⁄₈ " (714 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the framed depth must be measured from the drywall surface.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 4. Fireplace should be secured to side framing members using the full length nailing tabs at the top and bottom of the fireplace front face.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Step 4. Note: Chimney sections are constructed with a unique locking tab design, which en- sures an immediate, tight assembly between sections. Plan your chimney requirements care- fully before assembly as chimney is difficult to disassemble after installation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Locking Band Mastic Figure 29 Step 9. Security Chimneys locking bands, Model FLB, may be required if the chimney extends too high above the roof flashing.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 A ¹⁄₈ " diameter hole must be drilled in the chimney joint using a ¹⁄₈ " diameter drill. Hole should be drilled in center of joint overlap ( Figure 37 ). Be sure to drill only through the outer chimney casting.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 Figure 35 A 1 C 1 B 1 B 2 C 2 A 2 A 1 C 1 B 1 B 2 C 2 A 2 Figure 36 Chimney Section Joints No. 8 x 1/2" SMS Screws Required At Every Joint Past.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 Figure 37 Figure 38 Underside Of Chimney Chimney Section (S) FTF10-E30 Return Elbow* FTF10-30 Offset Elbow* B A *Part of Offset/Return Package Model FTF10-ES30 INSTALLING OFFSETS First, review the Offset Elevation Chart and Figure 38 for reference.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Note: See Framing and Dimension Chart for the sizes of the ceiling and roof openings. The size of the roof opening varies with the degree of pitch of the roof. Offset Elbow Assembly Offset elbows install the same as chimney sections.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Figure 42 Vent Free Appliances These units have been tested and approved to ANSI/IAS/AGA Z21.11.2 for use with unvented gas appliances and complies with the stan- dard for Factory-Built fireplaces, UL 127.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 43 Figure 44 Methods of Determining Hearth Extension and Wall Shield Equivalents To determine the thickness required for any material when ei.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 46 Figure 45 Secure the hearth extension to the floor to prevent possible shifting. FINISH TO YOUR TASTE There are a wide variety of “ finished looks ” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 63L16 FTF10-12 63L17 FTF10-18 Chimney Section 63L18 FTF10-36 Storm Collar 63L59 FSC 63L40 F10F6 Flashing 63L41 F10F12 Round Termination 63L423 FTF10.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 LENNOX reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
デバイスLennox ELITE SERIES LA41CFの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox ELITE SERIES LA41CFをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox ELITE SERIES LA41CFの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox ELITE SERIES LA41CFの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox ELITE SERIES LA41CFで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox ELITE SERIES LA41CFを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox ELITE SERIES LA41CFの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox ELITE SERIES LA41CFに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox ELITE SERIES LA41CFデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。