LennoxメーカーESTATE SERIES EST-48の使用説明書/サービス説明書
ページ先へ移動 of 20
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 48" Wood Burning Fireplaces P/N 850,006M REV. C 04/2004 EST -48 EST -48-H MODELS WH Report No. 629-915173 EST A TE SERIES This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 3 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL INSTALLATION *Construction Materials: • framing materials • paneling • particle board • flooring • millboard • dry wall • plywood • etc. PRECAUTIONS Note: These fireplace systems are not difficult to install.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 WARNING: IF INSULATION IS USED, THE FIREPLACE MUST NOT BE PLACED DI- RECTLY AGAINST IT. INSULATION OR VAPOR BARRIERS, IF USED, MUST FIRST BE COVERED WITH GYPSUM BOARD, PLYWOOD, PARTICLE BOARD OR OTHER MATERIAL TO ASSURE INSULATION AND VAPOR BARRIERS REMAIN IN PLACE.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Figure 5 Figure 7 Figure 6 The fireplace may be positioned and then the framing built around it, or the framing may be constructed and the fireplace positioned into the opening. Usually, no special floor support is needed for the fireplace, however, to be certain: 1.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 Figure 10 IMPORTANT: UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS ( FIGURE 10 ) BE REMOVED OR MODIFIED, NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPACERS. THE HEADER MAY BE IN DIRECT CONTACT WITH THE TOP SPACERS BUT MAY NOT BE SUPPORTED BY THEM.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 FRAMING SPECIFICATIONS Figure 11 Figure 12 Framing Dimensions for Ceiling Flue Type A B FTF13 Vertical 19" 19" (483 mm) (483 mm) FTF13 19&q.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Firestop Spacer Room Above Firestop Spacer Attic Above F10FS30-2 Firestop Spacer FTF10-S4 Stabilizer 2" Min. Air Space 30 ° Firestop And Attic Above 10' Max. Attic Space 2" Min. Air Space F10FS30-2 Firestop Spacer FTF10-S4 Stabilizer 30 ° Firestop And Room Above 10' Max.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Step 4. Note: Chimney sections are constructed with a unique locking tab design, which en- sures an immediate, tight assembly between sections. Plan your chimney requirements care- fully before assembly as chimney is difficult to disassemble after installation.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Locking Band Mastic Figure 30 Step 9. Security Chimneys locking bands, Model FLB, may be required if the chimney extends too high above the roof flashing.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 A ¹⁄₈ " diameter hole must be drilled in the chimney joint using a ¹⁄₈ " diameter drill. Hole should be drilled in center of joint overlap ( see Figure 38 ). Be sure to drill only through the outer chimney casting.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 FTF13 VERTICAL ELEVATION CHART 11 0 11 1 0 0 279 0.28 17 1 5 0 1 0 432 0.43 21 ¹⁄₄ 19 ¹⁄₄ 2 0 0 540 0.54 27 ¹⁄₄ 23 ¹⁄₄ 1 1 0 692 0.69 33 ¹⁄₄ 29 ¹⁄₄ 0 2 0 845 0.85 35 2 11 0 0 1 889 0.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 Figure 36 A 1 C 1 B 1 B 2 C 2 A 2 A 1 C 1 B 1 B 2 C 2 A 2 Figure 37 Chimney Section Joints No. 8 x 1/2" SMS Screws Required At Every Joint Past.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Step 3. Center outer-locking section over outer chimney pipe. Push down until locking joint has firmly engaged. Step 4. Pull up slightly on return elbow to ensure locking joint has firmly engaged. Step 5.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 OPTIONAL EQUIPMENT CONSIDERATIONS Gas Line Connection The EST-48 has been listed to accept a ¹⁄₂ " gas line for an approved gas appliance. Always have the appliance installed in accordance with all local building codes.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 45 Figure 44 A B D C C Hearth Extensions and Wall Shields A hearth extension must be installed with all fireplaces. It is to protect the floor in front of the fireplace from both radiant heat and sparks.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 47 FINISH TO YOUR TASTE There are a wide variety of “ finished looks ” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings. Only noncombustible materials like stone, tile, brick, etc.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 63L19 FTF13-12 63L20 FTF13-18 Chimney Section 63L21 FTF13-36 63L40 F10F6 Flashing 63L41 F10F12 Round Termination 63L44 FTF13-CTD Firestop Spacer (Fl.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
デバイスLennox ESTATE SERIES EST-48の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox ESTATE SERIES EST-48をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox ESTATE SERIES EST-48の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox ESTATE SERIES EST-48の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox ESTATE SERIES EST-48で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox ESTATE SERIES EST-48を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox ESTATE SERIES EST-48の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox ESTATE SERIES EST-48に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox ESTATE SERIES EST-48デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。