Lennox HearthメーカーEDVI35の使用説明書/サービス説明書
ページ先へ移動 of 20
neighbor’ s phone. Follow your gas suppliers instructions. • If your gas supplier cannot be reached, call the fi re department. Installation and service must be performed by a qualifi ed installer , service agency or the gas sup- plier . INST ALLA TION INSTRUCTIONS MANUAL DIRECT -VENT GAS FIREPLACE HEA TER INSERTS P/N 775,156M Rev .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 2 Installation must conform to local codes. In the absence of local codes, installation must comply with the current National Fuel Gas Code, ANSI Z223.1. (In Canada, the current CAN-1 B149 installation code.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 3 These appliances and their individual shut-off valves must be disconnected from the gas supply piping system during any pressure testing of that system at pressures greater than 1/2 psig (3.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 4 Installations at Altitudes of 0 to 4500 feet: These appliances have been tested and approved for elevations of 0 to 4500 feet (0 to 1370 meters).
5 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Figure 1 * The Steady State Effi ciency numbers based on maximum vent confi guration. DIMENSIONS Inches (millimeters) A B C N SM.= 41 1/16” (1043 mm) & MED.= 44 1/8” (1121 mm) D SM.= 26 1/16” (662 mm) & MED.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 6 I E F H J K L M G A B C N D Front View Side View SPECIFICA TIONS: EDVI30 & EDVI35 T op View Figure 2 DIMENSIONS EDVI30 EDVI35 Inches (millimeters) Inches (millimeters) A 32 1/16” (814 mm) C B 24 3/16” (614 mm) N 16 7/8” (427 mm) D 40 1/4” (1022 mm)Sm.
7 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. T op of Insert (see "C" on Fig. 3) 2 3 4 5 6 7 8 9 10 11 12 0 0 18" 17" 16" 15" 1 14" D C Figure 3 Figure 4a T a.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 8 IMPORT ANT NOTE: If propane is used, be aware that if the tank size is too small (i.e. under 100-lbs, if this is the only gas appliance in the dwelling. Ref. NPF A 58), there may be loss of pressure, resulting in insuffi cient fuel delivery (which can result in sooting or other malfunc- tions).
9 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Direct Vent System Components The following "Security Secure Vent TM " or "Simpson Dura-Vent" brand Collinear Direct-Vent components may be safely used with these appli- ances (see Figures 14 & 15).
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 10 Masonry Fireplace Installation Diagram Vertical T erm- ination Cap and Flashing. Cat. No. H0908 Liner Requirements: Vertical Height Min. = 8 ft. (2.44 M) Vertical height Max. = 40 ft. (12.2 M) See Direct Vent System Components on Page 9.
11 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Make gas line connections. All codes require a shut-off valve mounted in the supply line. Figure 18 illustrates two methods for connecting the gas supply. The fl ex-line method is acceptable in the U.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 12 The packaged log set, vermiculite and embers are located within the fi rebox of the insert. Installation Instructions: WARNING: IF LOGS ARE NOT IN.
13 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 8. Place the glowing embers on the burner as shown in Figure 27. One package of ember material has been included with this log set Y ou will not need to use the entire bag.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 14 3 . Place the Front Right Log and the Center Left Log onto the 2 cor - responding locating pins (each) as shown in Figure 30.
15 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. Proper Pilot Flame Appearance O N O F F P I L O T L O H I Figure 36a GAS CONTROL KNOB CONVERTIBLE HI/ LO REGUL ATOR (adju sts fl am e hei ght and .
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 16 T able 10 Burner Flame Appearance F ACTORY AIR SHUTTER SETTING INCHES (MILLIMETERS) Models Gas T ype Air Shutter Gap Natural Gas EDVI25 Propane Natural Gas 5/16" (7.94 mm) 3/16" (4.76 mm) EDVI30 Propane 1/2" (12.
17 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. SAFETY / LISTING LABELS - MODELS: EDVI30 & EDVI35 MODEL NO. ED VI35 MANUF A CTURED A T : Union City , TN FOR USE WITH NA TURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE MIN. GAS SUPPL Y PRESS (“ WC) PRESS MIN.
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 18 MODEL NO. ED VI25 MANUF A CTURED A T : L ynwood, CA FOR USE WITH NA TURAL GAS. EQUIPE POUR GAZ NATUREL ALTITUDE MIN.
19 NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. NOTE: THIS PAGE LEFT BLANK INTENTIONALL Y ..
NOTE: DIAGRAMS & ILLUSTRA TIONS NOT TO SCALE. 20 Printed in U.S.A. © Lennox Hearth Products 2003 P/N 775,156M REV . G 3/2005 Lennox reserves the right to make changes at any time, without notice, in design, materials, specifi cations, prices and also to discontinue colors, styles and products.
デバイスLennox Hearth EDVI35の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth EDVI35をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth EDVI35の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth EDVI35の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth EDVI35で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth EDVI35を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth EDVI35の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth EDVI35に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth EDVI35デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。