Lennox HearthメーカーLSO-43の使用説明書/サービス説明書
ページ先へ移動 of 20
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 1 43" Wood Burning Outdoor Fireplace P/N 850,015M REV. C 03/2007 LSO-43 LSO-43-H MODELS RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE OASIS SERIES This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 2 TABLE OF CONTENTS Safety Rules .................................... page 2 Tools and Building Supplies ............ page 2 Precautions ..................................... page 2 Introduction .......
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 3 Figure 1 TYPICAL FREE STANDING INSTALLATION (MUST BE A MINIMUM OF 10' AWAY FROM ANY BUILDING OR COMBUSTIBLE STRUCTURE) When complete, these fireplace systems con- sists of four basic “sub-systems”: 1.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 4 Figure 3 Figure 2 When choosing a location, care must be taken to avoid places where flooding or running water may be a problem.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 5 Figure 6 Figure 5 INSTALLING THE FIREPLACE Step 1. Slide the fireplace into prepared fram- ing or position fireplace in its final position and frame later. The fireplace may not be recessed into a com- bustible floor.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 6 FIREPLACE SPECIFICATIONS Figure 9 Step 3. Refer to fireplace drawings and speci- fications on pages 6 and 7 for framing dimen- sions and details. Frame appliance enclosure as illustrated in Figures 10 through 13 on page 7.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 7 Note: The framed depth, 25 ⁵⁄₈ " (651 mm) from a framed wall, must always be measured from a finished surface. If a wall covering such as drywall is to be attached to the rear wall, then the framed depth must be measured from the drywall surface.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 8 Step 4. The fireplace should be secured to the side framing members through the nailing flange ( Figure 16 ). Figure 16 Note: The nailing flange and the area directly behind the nailing flange is exempt from the clearances described on the fireplace clear- ance label.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 9 Figure 20 Figure 21 Figure 22 The outer chimney section installs the opposite way; the lanced end goes down and each new section installs OVER the outside of the previ- ous section ( Figure 23 ). Figure 23 Continue to assemble the chimney up through framed opening.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 10 Note: If chimney extends more than 8' above roof surface, guy wires are also recommended. Use three (3) guy wires, attach to locking band assembly, extend and secure to roof in a triangular pattern (Figure 29 ).
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 11 MULTIPLE TERMINATIONS If more than one termination is located in the same chase or within the same general prox- imity, we suggest they should be se.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 12 Figure 34 Figure 35 Return elbow support straps must be securely attached under tension (in shear) to structural framing members above. Do not substitute a FTF10-30 offset elbow in place of a FTF10-E30 return elbow.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 13 FTF10 VERTICAL ELEVATION CHART 11 0 11 1 0 0 279 0.28 17 1 5 0 1 0 432 0.43 21 ¹⁄₄ 19 ¹⁄₄ 2 0 0 540 0.54 27 ¹⁄₄ 23 ¹⁄₄ 1 1 0 692 0.69 33 ¹⁄₄ 29 ¹⁄₄ 0 2 0 845 0.85 35 2 11 0 0 1 889 0.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 14 Figure 36 Figure 37 INSTALLING OFFSETS First, review the Offset Elevation Chart and Figure 37 for reference. Step 1. Determine the offset distance where chimney is to pass through the first ceiling- dimension “A.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 15 Note: See Framing and Dimension Chart for the sizes of the ceiling and roof openings. The size of the roof opening varies with the degree of pitch of the roof. Offset Elbow Assembly Offset elbows install the same as chimney sections.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 16 Figure 41 A B D C C Figure 40 Hearth Extension Dimensions Opening Width 43" A 20" (508 mm) B 43" (1092 mm) C 12" (305 mm) D 62" (1575 mm) Finished Wall Header Noncombustible Wall Covering Fireplace Opening U.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 17 Figure 42 Side Wall cannot be Closer than 12" (305mm) under any Circumstances A B C C D Wall Shield Calculating Minimum Thickness if Multiple Materials are Used At times it is important to know what combination of materials are acceptable for use as floor protection.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 18 Storm Collar 63L59 FSC Locking Band 63L60 FLB Figure 44 FINISH TO YOUR TASTE There are a wide variety of “finished looks” for these fireplaces, from formal wall decor with elaborate mantels to rustic wood paneling or warm brick facings.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 19 63L16 FTF10-12 63L17 FTF10-18 Chimney Section 63L18 FTF10-36 63L40 F10F6 Flashing 63L41 F10F12 Round Termination 63L43 FTF10-CTD Chase Termination (.
NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 20 LENNOX reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
デバイスLennox Hearth LSO-43の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth LSO-43をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth LSO-43の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth LSO-43の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth LSO-43で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth LSO-43を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth LSO-43の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth LSO-43に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth LSO-43デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。