Lennox Hearth ProductsメーカーBrentwood SPの使用説明書/サービス説明書
ページ先へ移動 of 24
EP A W ood -Bu rni ng Fir epl ace s P/N 8 50, 039 M REV . G 1 1/2 008 BRENTWOOD SP MODEL BRENTWOOD™ This installation manual will enable you to obtain a safe, efficient and dependable installation of your fireplace system. Please read and understand these instructions before beginning your installation.
W ARNING T o avoid the risk of damaging fireplace materials and increas- ing the risk of fire, do not use the fireplace to cook or warm food. IMPORT ANT! GENERAL SAFETY PRECAUTIONS. READ AND UNDERST AND THESE SAFETY R U L E S B E F O R E Y O U R F I R S T F I R E .
T ABLE OF CONTENTS Safety Rules and Specifications for Mobile or Manufactured Home Installation ......................... Page 2 Introduction ...................................... Page 3 Parts Required ................................. Page 3 Optional Equipment .
Building a Fire (starting and maintaining a fire) T o start a fire, place several crumpled up balls of newspa per in the firebox. Place small dry pieces of kindling on top of the paper , criss-crossing the kindling so that there are air spaces in be- tween.
B. Blowers operating (e.g.: range hood) These blowers draw air out of the house and may actually cause a negative pressure in the house. T urn off all blowers and open a nearby window to determine if this is the cause of the problem. C. Wet wood W et or tarred wood will smoulder and smoke instead of burn properly .
REFRACTORY REPLACEMENT The intense heat of the fire will normally cause hairline cracks in the refractor y . These cracks can be minimized by proper curing as described in “First Fires”. They will not normally dimin- ish the effectiveness of the refractor y .
GLASS CARE Glass Replacement The glass used for the Brentwood™ fireplace is a high temperature ceramic glass (1,400° F). If the glass breaks, it must be replaced with an identical ceramic glass. T empered glass or ordinary glass will not withstand the high temperatures of the Brentwood fireplace.
Framing, Facing And Mantel The construction of the framing, facing, and mantel must be in accordance with the stan- dards and the following illustrations ( Figure s 7a, 7b and 8 ): A.
C om b u s ti b l e ma t er i a ls c a n N O T be us e d i n t he s p ac e di re c tl y ab ov e t h e fi re p la c e . D o n ot fi l l t h e sp a ce a bo ve th e fir ep l ac e wi th an y m at e r i al ( Ex ce p t t h e wo o d f r am in g ) F 19 -3 /3 2” J 20-1/2” E 7’ Min.
Facing 1. Combustible material must be installed flush with the fireplace. It may not project in front of and on the fireplace (i.e. the steel facade of the fireplace) ( Figure 10 ) . 2. Non-combustible materials such as brick, stone or ceramic tile may project in front of and onto the fireplace facing ( Figure 11 ) .
HOT AIR DUCTING INST ALLA TION The Brentwood™ fireplace is approved for use with a Gravity Kit. Gravity Kit The gravity kit is designed for double hot air out- lets and includes: (See Figures 12 and 13 ) - 2 telescopic lengths 8” I.D. - 2 90º elbows 8” I.
6- 1/2 ” Mi n. (t o c ei li ng) Figure 13 Figure 14 Flashing Collar Rain Cap Roof Support Attic Radiation Shield Radiation Shield (Firestop) Non-Combustible Facing Maintain at least 6-1/2” (160 mm) clearance from the outlet grill framing to a combustible ceiling, side wall or mantel.
The duct system must be installed respecting the following: 1. Remo ve the plat es clo sing up the 8” dia. hol es on top of the fireplace. Then, cut the insula- tion in order to obtain two 8” dia. openings. Fix the adaptors on the fireplace openings by turning clockwise ( Figure 12 ) .
6. The chimney must extend at least three (3) feet (915 mm) above its point of contact with the roof and at least two (2) feet (610 mm) higher than any wall, roof or building within ten (10) feet (3m) of it ( Figure 17 ) .
CHIMNEY INST ALLA TION INSTRUC- TIONS 1. Cut and frame the holes in the ceiling, floor and roof where the chimney will pass (see Figure 18 ). Use a plumb-bob to line up the center of the holes. The sizes are indicated in T able 2 for the floor and ceiling holes and T able 3 ( Page 13 ) for the roof holes.
Roof Down Slope Hole Size S LO P E A SH T / H T 6 1 03 + S -2 1 0 0 + / H T6 0 0 0 + A C R oo f P it c h 6 ” 6 ” 6 ” 0 * 1 2- 3 / 8 ” ( 3 1 4 m m ) 1 4- 1 / 8 ” ( 3 5 9 m m ) 1 5” ( 38 0 m.
Ch imn ey 6” Elbo w Offset & Height One Length Between Elbows T wo Lengths Between Elbows 8” 12” 18” 24” 36” 48” 8” & 48” 1 2” & 4 8” 1 8 ” & 48 ” 2 4” &.
ANGLED WALL RADIA TION SHIELD (RSM+ and RSMI30) When traversing a combustible wall with the chimney at a 30º or 45º angle, an angled firestop or wall radiation shield must be installed.
CHIMNEY SUPPORT INST ALLA TION Universal Roof Support This support has three possible uses: 1. For ASHT / HT6103+ and S-2100+ / HT6000+, it must be used on a roof to support the chimney . 2. It may be used on a floor , ceiling or roof above an offset to support the chimney above the offset.
Follow these steps: 1- Position the fireplace in its location. T emporarily install the ASHT elbow on the top of the fireplace and, using a level, mark with an oval the location where the flue liner will enter the masonry chimney . 2- In the middle of the oval, drill a hole in the masonr y chimney at 30º.
Installation Accessories Description Cat./Part No. (Required - Order Separately) Black Cast Iron Door for Brentwood ™, BWBK H0516 Gold Plated Cast Iron Door for Brentwood, BWG H0517 Brushed Nickel C.
(AC) Air -Cooled Chimney System* 6” I.D. and 11” O.D. Air Cooled, Stainl. Steel inner and zinc coated steel exterior AC Starter Adaptors One of the following adaptors is required if installing an .
CLEARANCE TO COMBUSTIBLES The following clearances meet the minimum requirements for a safe installation: Side wall: 17” (324 mm) measured from the fireplace side.
Printed in Canada © 2006 Lennox Hearth Products P/N 850,039M REV . G 11/2008 24 Y our Fireplace's Model Number ________________________________________ Y our Fireplace's Serial Number _____.
デバイスLennox Hearth Products Brentwood SPの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth Products Brentwood SPをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth Products Brentwood SPの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth Products Brentwood SPの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth Products Brentwood SPで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth Products Brentwood SPを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth Products Brentwood SPの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth Products Brentwood SPに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth Products Brentwood SPデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。