Lennox Hearth ProductsメーカーLSM40MP-2の使用説明書/サービス説明書
ページ先へ移動 of 32
D RAF T 3 / 0 8 / 2 0 1 0 INST ALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. INST ALLA TEUR: Laissez cette notice avec l'appareil. CONSOMMA TEUR : Conservez cette notice pour consul- tation ultérieure.
2 T ABLE OF CONTENTS Packaging ......................................... Page 2 Introduction ...................................... Page 2 General Information .......................... Page 2 Massachusetts and New Y ork Requirements .................
3 Note: Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional ser vice person. More frequent cleaning may be required due to excessive lint from carpeting, bed- ding material, etcetera.
4 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. These appliances must be isolated from the gas supply piping system (by closing their individual manual shut-off valve) during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 5 LOCA TION In selecting the location, the aesthetic and functional use of the appliance are primar y concerns. However , vent system routing to the exterior and access to the fuel supply are also important.
6 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 3" (76 mm) T ermination Kit Combustible Projection greater than 2-1/2 inches in length Horizontal Vent T ermination Clearances Combustible .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 7 EXTERIOR HORIZONT AL VENT TERMINA TION CLEARANCE REQUIREMENTS Mi ni m um C l ea ra n ce s Ca na d ia n I ns ta l la ti o n * US I n st al l at io n * * A = Cle ara n c e abo v e gra de, ve r an da, po r ch, de c k or b al c o ny .
8 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. *Note: 3 in. (75 mm) above any horizontal/inclined vent component. **N ot e: See Page 9, Step 1 for clearance requirements to the nailing flange located at each side of the unit and any screw heads adjacent to it.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 9 Left Side Front Corner of Fireplace Shown (Right Side Requirements the Same) Unit Being Secured By Its Nailing Flanges T o The Framing Note : Th.
10 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. E A B D T op View Front View 5-3/32 (129) Right Side View 14-1/8 8-1/2” (216) 5-1/4” (133) (359) 26-15/32 (672) C 25-29/32 (658) 25-1/2 (648) 7 2-1/2 (64) (178) 19-5/8 (498) Gas Inlet (This Side Only) Electrical Inlet 8-3/8 (213) F G H J Fireplace Dimensions M o d e l N o .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 11 C Back wall of chase/enclosure (including any finishing materials) D A B Model No. A B C D LSM40-2 in.
12 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 15 Figure 16 AIR INLET BAFFLE GRA TE VENT RESTRICTOR INSTALLATION RESTRICTOR APPLIANCE VENT OUTLET Install the restrictor as shown from inside the unit, in the inner fireplace collar .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 13 T ermination Flashing An d Storm Collar Fires top/Spacer SV 8 6/12/24/36/48 V ent Section s 40' Ma x (12.
14 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 18 Vertical (Offset) Installation Analyze the vent routing and determine the qua nti ti es of ven t sec tio ns and numb er of elbow s required. Refer to Vertical Vent Figures and T ables on Page 16 to select the type of vertical installation desired.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 15 Fr ami ng D ime nsi on s for R oo f In che s (m ill ime te rs ) Pi tch C D 0/ 12 13 i n. (3 30 mm ) 13 in . (3 30 mm ) 6/ 12 13 i n. (3 30 mm ) 15 -1/ 2 in . (3 94 mm ) 12 /12 1 3 in . (3 30 mm ) 20 -1/ 2 in .
16 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 27 - T op V ent - THREE ELBOWS V H 1 H V 1 Ceiling Firestop/Spacer (SV8BF) Wall Firestop/Spacer (SV8HF) T abl e B H + H 1 M ax imu m V M ini m um fe e t (m et er) fe e t (m ete r ) 10 ( 3.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 17 Vertical Rise SV8E90 Elbow Horizontal / Inclined Run SV8HTS T ermination Shown Firestop/Spacer SV8 L6/12/24/36/48 Vent Sections Support Bracket.
18 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Horizontal terminations have been designed to perform in a wide range of weather condi- tions.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 19 H V Wall Firestop/Spacer (SV8HF) Ceiling Firestop/Spa ce r (SV8BF) T abl e C H Max im um V Mi nim um fe et (m ete r) f ee t ( m et er) 3. 5 (1 .07 ) 2.5 (0 . 7 6 2) 6. 5 (1 .98 ) 3.5 (1 . 07 ) 8.
20 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Figure 33 - T op Vent - THREE 90 DEGREE ELBOWS See T able 8 on Page 19 as an aid in venting component selection for a particular range of exterior wall thicknesses.
21 Step 4. FIELD WIRING CAUTION Ground supply lead must be con- nected to the wire attached to the green ground screw located on the outlet box. See Figures 35 and 36 .
22 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 5. REMOVE GLASS DOOR FRAME Remove glass door assembly . See Removing Glass Enclosure Panels on Page 26 . Step 6. CONNECTING GAS LINE All codes require a shut-off valve mounted in the supply line.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 23 W ARNING Never use an open flame to check for leaks. T u r n on gas su pp l y an d tes t fo r gas lea k s us i ng a ga s l ea k te st s olu ti o n ( al s o re fer re d t o a s b ub b le le a k s ol u ti o n) .
24 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Step 1. Install the ceramic panels per the instructions provided in kit (reference form #750182M). Step 2. Place a mixture of volcanic stone and vermiculite around the burner as shown in Figure 43 .
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 25 Figure 44 Align Groove At The Bottom Of Log (2) Over The Grate And Push It T owards The Rear . 2 Align T wo Holes At Bottom Of Log (1) Over The Pins On The Gas Burner . Engage Logs (3 & 4) With The Grate Pins And Align Groves At The Bottom Of The Logs Over The Grate.
26 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. Only doors certified with the appliance shall be used. Seules des portes certifiées pour cet appareil doivent être utilisées. CAUTION: DO NOT abuse glass door by striking or slamming shut. Step 10.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 27 Figure 52 - Burner Flame Appearance (Rustic Oak Logs Shown) LSM45-2 Figure 51 - Burner Flame Appearance (Birch Logs Shown) LSM40-2 T o adjust the flame, rotate the air shutter toward the back or toward the front of the fireplace.
28 Glass Door Assembly Fireplace Finish Combustible Or Non-Combustible Material Bottom Of Fireplace 1/8 Inch Minimum Door T rack Finish Combustible Or Non-Combustible Material Front Face Of Fireplace .
29 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. La chimenea caliente cau- sará quemaduras graves Nunca permita que los niños toquen el vidrio ni otras partes de la chimenea ADVERTENCIA Un f.
30 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. INST ALLA TION ACCESSORIES Listed Secure Vent™ Components Cat.
NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 31 In Canada: THE CONVERSION SHALL BE CAR- RIED OUT IN ACCORDANCE WITH THE REQUIREMENTS OF THE PROVINCIAL AUTHORITIES HA VING JURISDICTION AND IN ACCORDANCE WITH THE RE- QUIREMENTS OF THE CAN/CSA-B149.
32 NOTE: DIAGRAMS & ILLUSTRA TIONS ARE NOT TO SCALE. 1508 Elm Hill Pike, Suite 108 • Nashville, TN 37210 Figure 59 Step 8. Reassemble the remaining components by reversing the procedures outlined in the preceding steps. Step 9. Attach the conversion label provided in the conversion kit to the rating plate on the appliance.
デバイスLennox Hearth Products LSM40MP-2の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lennox Hearth Products LSM40MP-2をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLennox Hearth Products LSM40MP-2の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lennox Hearth Products LSM40MP-2の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lennox Hearth Products LSM40MP-2で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lennox Hearth Products LSM40MP-2を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLennox Hearth Products LSM40MP-2の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lennox Hearth Products LSM40MP-2に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLennox Hearth Products LSM40MP-2デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。