P/No .: 3828A20025U.
LG Floor Standing Type Air Conditioner INSTALLATION MANUAL LG website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html IMPORTANT • Please read this installation manual completely before installing the product.
2 Floor Standing type Air Conditioner Floor Standing T ype Air Conditioner Installation Manual T ABLE OF CONTENTS Safety Precautions .......................................................................................... 3 Installation of Indoor , Outdoor Unit .
Safety Precautions Installation Manual 3 ENGLISH T o prev ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollowed. ■ Incorrect operation due to ignoring instruction will cause har m or damage. The seriousness is classified by the f ollowing indications .
4 Floor Standing type Air Conditioner Safety Precautions Do not modify or extend the power cab le. • There is risk of fire or electric shock. Be cautious when unpacking and installing the product. • Sharp edges could cause injur y . Be especially careful of the case edges and the fins on the condenser and ev aporator .
Safety Precautions Installation Manual 5 ENGLISH Alwa ys check f or gas (refrigerant) leakage after installation or repair of product. • Low refrigerant le vels ma y cause f ailure of product. Install the drain hose to ensure that water is drained awa y properly .
6 Floor Standing type Air Conditioner Installation of Unit Installation of Unit 1. Indoor unit • There should not be an y heat source or steam near the unit. • There should not be an y obstacles to pre vent the air circulation. • A place where air circulation in the room will be good.
Installation of Unit Installation Manual 7 ENGLISH 3. Piping length and the elevation CA UTION: • Capacity is based on standard length and maxim um allowance length is on the basis of reliability . • Oil trap should be installed every 5~7 meter s.
8 Floor Standing type Air Conditioner Installation of Unit The Indoor Unit Installation Outdoor unit Installation 200mm 70mm 70mm 90mm Wall Core Drill Tilt Cut if necessary More than 15mm Wall Plastic tube (Bushing) INSIDE OUTSIDE 1. The mounting floor should be strong and solid enough to prev ent it from vibration.
Installation of Unit Installation Manual 9 ENGLISH Installation guide at the seaside 1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced. 2. Do not install the product where it could be exposed to sea wind (salty wind) directly.
10 Floor Standing type Air Conditioner Installation of Unit Installation Method No. Installation works Descriptions 1 Preparation of tools and installation parts Preparation of installation 2 Flaring the pipes T o insert the flare nuts, mounted on the connection par ts of both indoor and outdoor unit, onto the copper pipes .
Installation of Unit Installation Manual 11 ENGLISH Preparation of installation par ts and tools No. Installation Parts, T ools Use 1 Flaring tool ( Ø 6.
12 Floor Standing type Air Conditioner Installation of Unit Preparation of Piping Main cause of gas leakage is def ect in flaring work. Carr y out correct flaring work in the f ollowing procedure. 1. Cut the pipes and the cable . • Use the accessor y piping kit or the pipes purchased locally .
Installation of Unit Installation Manual 13 ENGLISH Connection of piping • Align the center of the pipings and suffciently tighten the flare nut with fingers.
14 Floor Standing type Air Conditioner Installation of Unit Connecting the Cable to Indoor Unit • The inside and outside connecting cable can be connected after opening the side inlet g rille. 1. Open the side-inlet grille manually (Fig. 1) 2. Open the panel (A) with driver ( ) (Fig.
Installation of Unit Installation Manual 15 ENGLISH Connecting pipings to the outdoor unit . 1. Align the center of the pipings and sufficiently tighten the flare nut with fingers. 2. Finally tighten the flare nut with tor que wrench until the wrench c licks.
16 Floor Standing type Air Conditioner Installation of Unit P o wer Supply and Wiring The unit is completely wired internally at the factory according to general rule of electrical technology , but local rules, if the y are required, should be complied with.
Installation of Unit Installation Manual 17 ENGLISH V acuum Drying of the Connecting Pipes and the Indoor Unit The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor . 1. Confir m that both the liquid side valv e and the gas side valve are set to the closed position.
18 Floor Standing type Air Conditioner Installation of Unit Form the Piping 1. Wrap the connecting por tion of indoor unit with the insulation material and secure it with two Plastic Bands. (for the right piping) • If y ou connect an additional drain hose, the end of the drain-outlet should be kept distance from the gr ound.
Final Check and T est Run Installation Manual 19 ENGLISH After installing the unit, perform the final check and running test as follows: Final check points Is the unit securely mounted? Is the install.
デバイスLG Electronics 3828A20025Uの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
LG Electronics 3828A20025Uをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLG Electronics 3828A20025Uの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。LG Electronics 3828A20025Uの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。LG Electronics 3828A20025Uで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
LG Electronics 3828A20025Uを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLG Electronics 3828A20025Uの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、LG Electronics 3828A20025Uに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLG Electronics 3828A20025Uデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。