LG Electronicsメーカー3828A20025Vの使用説明書/サービス説明書
ページ先へ移動 of 20
LG Floor Standing Type Air Conditioner INSTALLATION MANUAL LG website http://www.lgservice.com e-mail http://www.lgeservice.com/techsup.html IMPORTANT • Please read this installation manual completely before installing the product.
2 Floor Standing type Air Conditioner Floor Standing T ype Air Conditioner Installation Manual T ABLE OF CONTENTS Safety Precautions .......................................................................................... 3 Installation of Indoor , Outdoor Unit .
Safety Precautions Installation Manual 3 T o prev ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollowed. ■ Incorrect operation due to ignoring instruction will cause har m or damage. The seriousness is classified by the f ollowing indications .
4 Floor Standing type Air Conditioner Safety Precautions Do not modify or extend the power cab le. • There is risk of fire or electric shock. Be cautious when unpacking and installing the product. • Sharp edges could cause injur y . Be especially careful of the case edges and the fins on the condenser and ev aporator .
Safety Precautions Installation Manual 5 Alwa ys check f or gas (refrigerant) leakage after installation or repair of product. • Low refrigerant le vels ma y cause f ailure of product. Install the drain hose to ensure that water is drained awa y properly .
6 Floor Standing type Air Conditioner Installation of Unit Installation of Unit 1. Indoor unit • There should not be an y heat source or steam near the unit. • There should not be an y obstacles to pre vent the air circulation. • A place where air circulation in the room will be good.
Installation of Unit Installation Manual 7 3. Piping length and the elevation CA UTION: • Capacity is based on standard length and maxim um allowance length is on the basis of reliability .
8 Floor Standing type Air Conditioner Installation of Unit The Indoor Unit Installation Outdoor unit Installation 200mm 70mm 70mm 90mm Wall Core Drill Tilt Cut if necessary More than 15mm Wall Plastic tube (Bushing) INSIDE OUTSIDE 1. The mounting floor should be strong and solid enough to prev ent it from vibration.
Installation of Unit Installation Manual 9 Installation guide at the seaside 1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced. 2. Do not install the product where it could be exposed to sea wind (salty wind) directly.
10 Floor Standing type Air Conditioner Installation of Unit Installation Method No. Installation works Descriptions 1 Preparation of tools and installation parts Preparation of installation 2 Flaring the pipes T o insert the flare nuts, mounted on the connection par ts of both indoor and outdoor unit, onto the copper pipes.
Installation of Unit Installation Manual 11 Preparation of installation par ts and tools No. Installation Parts, T ools Use 1 Flaring tool ( Ø 6.35 - Ø 19.
12 Floor Standing type Air Conditioner Installation of Unit Preparation of Piping Main cause of gas leakage is def ect in flaring work. Carr y out correct flaring work in the f ollowing procedure. 1. Cut the pipes and the cable . • Use the accessor y piping kit or the pipes purchased locally .
Installation of Unit Installation Manual 13 Connection of piping • Align the center of the pipings and suffciently tighten the flare nut with fingers.
14 Floor Standing type Air Conditioner Installation of Unit Connecting the Cable to Indoor Unit • The inside and outside connecting cable can be connected after opening the inlet g rille.
Installation of Unit Installation Manual 15 Connecting pipings to the outdoor unit . 1. Align the center of the pipings and sufficiently tighten the flare nut with fingers. 2. Finally tighten the flare nut with tor que wrench until the wrench c licks.
16 Floor Standing type Air Conditioner Installation of Unit P ower Suppl y and Wiring The unit is completely wired internally at the factory according to general rule of electrical technology , but local rules, if the y are required, should be complied with.
Installation of Unit Installation Manual 17 V acuum Drying of the Connecting Pipes and the Indoor Unit The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor . 1. Confir m that both the liquid side valv e and the gas side valve are set to the closed position.
18 Floor Standing type Air Conditioner Installation of Unit Form the Piping 1. Wrap the connecting por tion of indoor unit with the insulation material and secure it with two Plastic Bands. (for the right piping) • If y ou connect an additional drain hose, the end of the drain-outlet should be kept distance from the gr ound.
Final Check and T est Run Installation Manual 19 After installing the unit, perform the final check and running test as follows: Final check points Is the unit securely mounted? Is the installation lo.
20 Floor Standing type Air Conditioner Memo.
デバイスLG Electronics 3828A20025Vの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
LG Electronics 3828A20025Vをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLG Electronics 3828A20025Vの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。LG Electronics 3828A20025Vの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。LG Electronics 3828A20025Vで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
LG Electronics 3828A20025Vを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLG Electronics 3828A20025Vの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、LG Electronics 3828A20025Vに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLG Electronics 3828A20025Vデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。