LG Electronicsメーカー3828A30087Sの使用説明書/サービス説明書
ページ先へ移動 of 33
ENGLISH LG Room Air Conditioner INSTALLATION MANUAL LG http://www.lgservice.com IMPORTANT • Please read this instruction manual completely before installing the product. • When the power cord is damaged, replacement should be performed by authorized personnel only.
2 Room Air Conditioner Room Air Conditioner Installation Manual T ABLE OF CONTENTS Safety Precautions ......................... 3 Introduction .....................................9 Symbols Ued in This Manual ......9 Features .........................
Installation Manual 3 ENGLISH Safety Precautions T o pre vent the injury of the user or other people and proper ty damage, the follo wing instructions must be f ollowed. ■ Incorrect operation due to ignoring instruction will cause har m or damage. The seriousness is classified by the f ollowing indications.
4 Room Air Conditioner Safety Precautions ■ Operation Be cautious when unpacking and installing the product. • Shape edges could cause injury . Be especially careful of the sharp edges. For installation, always contact the dealer or an A uthorized Service Center .
Installation Manual 5 ENGLISH Safety Precautions Do not place a heater or other appliances near the power cable. • There is risk of fire, failure of the product, and/or electric shock. Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
6 Room Air Conditioner Saf ety Precautions ■ Installation Alwa ys check f or gas(refrig erant) leakage after installation or repair of product. • Low refrigerant le vels ma y cause product failure . Install the drain hose to ensure that water is drained awa y properl y .
Safety Precautions Installation Manual 7 ENGLISH ■ Operation Do not install the product where the noise or hot air from the outdoor unit could damage the neighborhoods. • It may cause a prob lem for your neighbors. Use two or more people to lift and transport the air conditioner • A void personal injury .
8 Room Air Conditioner Saf ety Precautions ■ Disuse Alwa ys insert the filter securely . Clean the filter every two weeks or more often if necessary . • A dir ty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage.
Installation Manual 9 ENGLISH Introduction This symbol alerts you to the risk of electric shock. This symbol alerts you to hazards that ma y cause harm to the air conditioner .
10 Room Air Conditioner Installation Type "A" screw and plastic anchor Type "B" screw Remote Control Holder Installation plate Figure Figure Name Screw driver Electric Drill Measur.
Installation parts you should purchase. Vinyl tape (Wide) • Apply after carrying out a drainage test. • To carry out the drainage test, remove the air filters and pour water into the heat exchanger.
Installation 1. Check the quality label on the indoor and outdoor unit. 2. Make cer tain that the refrigerant is R-410A. THIS PRODUCT CONT AINS R-410A REFRIGERANT 1) Diff erent compressor oil - R-410A(P olyol ester) / R-22(Mineral). - Do not mix the e xisting mineral oil.
Installation Manual 13 ENGLISH Installation Outdoor unit 1. If an awning is built o ver the unit to pre vent direct sunlight or rain e xposure, make sure that heat radiation from the condenser is not restricted. 2. Ensure that the space around the back and sides is more than 30cm(11.
12k Ø 12.7mm(1/2") Ø 6.35mm(1/4") 7.5(25) 7.5(25) 15(49) 20(0.22) 14 Room Air Conditioner Installation Piping Length And Elev ation • Capacity is based on standard length and maximum allo wance length is on the basis of reliability . • Oil trap should be installed e ver y 5~7meters (16.
Installation Manual 15 ENGLISH Installation The wall y ou select should be strong and solid enough to pre vent vibr ation 1. Mount the installation plate on the wall with type "A" screws . If mounting the unit on a concrete wall, use anchor bolts .
16 Room Air Conditioner Installation Flaring W ork Cut the pipes and the cable. 1. Use the piping kit accessor y or the pipes purchased locally . 2. Measure the distance between the indoor and the outdoor unit. 3. Cut the pipes a little longer than measured distance.
Installation Manual 17 ENGLISH Installation Indoor 1. Prepare the indoor unit's piping and drain hose for installation through the w all. 2. Remove the plastic tubing retainer(see the illustration b y) and pull the tubing and drain hose aw ay from chassis .
18 Room Air Conditioner Installation Wrap the insulation material around the connecting portion. • Overlap the connection pipe insulation material and the indoor unit pipe insulation material. Bind them together with vinyl tape so that there is no gap .
Installation Manual 19 ENGLISH Installation Insert the connecting cable into the indoor unit. • Don't connect the cable to the indoor unit. • Make a small loop with the cab le for easy connection later . T ape the drain hose and the connecting cable .
20 Room Air Conditioner Installation Reroute the pipings and the drain hose across the bac k of the chassis. Reroute the pipings and the drain hose across the bac k of the chassis.
Installation Manual 21 ENGLISH Installation Installation Inf or mation. For left piping. Follo w the instruction below . Correct case • Press on the upper side of clamp and unf old the tubing to downward slowly . Incorrect case • F ollowing bending type from right to left may cause damage to the tubing.
22 Room Air Conditioner Installation Put a couple drops of refrigerant oil on the face of the flare before assembling taking care not to add any contaminants. Align the center of the pipings and sufficiently tighten the flare nut by hand. • The drain hose can be connected at two different positions.
Installation Manual 23 ENGLISH Installation Connecting the Piping Connection Of The Cable 1 Indoor Unit Outdoor Unit 2 3 4 1 2 3 4 5 6 G To branch circuit Ground P ower supply a L1 * L2 Connecting cable(Low v oltage) b T erminal (4P) T erminal (6P) Outdoor unit Wiring Diagram T erminal block Over 5mm (0.
24 Room Air Conditioner Installation After the confirmation of the above conditions , prepare the wiring as follows: 1) Never fail to have an individual po wer circuit specifically f or the air conditioner . As f or the method of wiring, be guided by the circuit dia gram posted on the inside of control cover .
Installation Manual 25 ENGLISH Installation Chec king The Drainage • P our a glass of water on the drain pan. • Ensure the water flows through the drain hose of the indoor unit without an y leakage and goes out the drain exit. Drain piping • The drain hose should point downw ard for easy dr ain flow .
26 Room Air Conditioner Installation Forming The Piping Form the piping by wrapping the connecting portion of the indoor unit with insulation material and secure it with two kinds of vin yl tapes. • If you w ant to connect an additional drain hose , the end of the drain outlet should be routed abo ve the ground.
Installation Manual 27 ENGLISH Air Purging Air purging With V acuum Pump Lo Hi Indoor unit Outdoor unit Manifold valve Charge hose Nitrogen gas cylinder(in vertical standing position) Pressure gauge Air and moisture remaining in the refrigerant system ha ve undesira ble eff ects as indicated below .
28 Room Air Conditioner Installation Evacuation • Connect the charge hose end described in the preceding steps to the vacuum pump to ev acuate the tubing and indoor unit. Confirm the "Lo" knob of the manifold valv e is open. Then, run the vacuum pump .
Installation Manual 29 ENGLISH Installation Charging ■ Each outdoor unit is factory charged (nameplate charge) for the e vaporator as well as a 7.5m(25ft) line set. Any time a line set is used either shor ter or longer then the nominal 7.5m(25ft) line set length the refrigerant charge has to be adjusted.
30 Room Air Conditioner T est Running Outside ambient TEMP . The pressure of the gas side ser vice valve 95 ° F(35 ° C) 8.5~9.5kg/cm 2 G(120~135 P .S.I.G.) Settlement of outdoor unit ■ Anchor the outdoor unit with a bolt and nut( ø 10mm(0.39in) tightly and horizontally on a concrete or rigid mount.
Installation guide at the seaside Installation Manual 31 ENGLISH Installation guide at the seaside 1. Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced. 2. Do not install the product where it could be exposed to sea wind (salty wind) directly.
32 Room Air Conditioner.
P/No .: 3828A30087S.
デバイスLG Electronics 3828A30087Sの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
LG Electronics 3828A30087Sをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLG Electronics 3828A30087Sの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。LG Electronics 3828A30087Sの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。LG Electronics 3828A30087Sで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
LG Electronics 3828A30087Sを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLG Electronics 3828A30087Sの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、LG Electronics 3828A30087Sに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLG Electronics 3828A30087Sデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。