P OWER P ROTECTION UPSta tion GXT ™ 6 kV A Maintenance Bypass U SER M ANUAL Transformerless with Configurable Output Distribution.
.
i T ABLE OF CONTENT S I MPORTANT S AFETY I NSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 G LOSSARY OF S YMBOLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
1 IMPORT ANT SAFETY INSTRUCTIONS SA VE THESE INSTRUCTIONS This manual cont ains import ant instructions tha t should be c losely follow ed during installation and maintenance of this UPS tation GXT 6kV A Maintenance Byp ass. This product is designed fo r commercial / industr ial use only .
2 GLOSSARY OF SYMBOLS Risk of electrical shock Indicates W arning or Caution foll owed by import ant instructions Request s the user to consult the manual Equipment grounding conductor On Off i.
3 GENERAL DESCRIPTION Congratulation s on you r purchase of Liebert's UPS tation GXT 6 kV A Maintenance Bypass. As with every Liebert product, we st and behind our quality .
4 Maintenance Byp ass component layout UPS input switch (SW2) Output breaker (CB1) Configurable Output Distribution Bypass availability indicator (amber) UPS input power present (amber) Bypass switch .
5 MAJOR COMPONENT S The following is a genera l description of ea ch component and it s functions. Please review this section carefully , as it will give you a better understan ding as to how the UPS tation GXT 6 kV A Maintenance Byp ass operates.
6 CABLE INST ALLATION W IRING P REP ARATION For access to terminal blocks, see diagrams on pag e 4. P OWER C ABLE I NST ALLATIO N Refer to the chart be low when selecting cable s: ! CAUTION Please read this section thoroughly before attempting to install wiring to this unit.
7 Connecting Maintenance Byp ass to UPS t ation GXT6000T - 208 12 3 4 MAINTENANCE BYP ASS GND 1 208 VA C GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 132 132 13 4 L1 L2 L1 L2 +- Input Output Ext. battery Utility input L1 L2 NOTE GMB12 models are supp lied with an attached input power cord complete with L14-30 plug.
8 Connecting Maintenance Byp ass to UPSt ation GXT6000T - 208X 12 3 4 MAINTENANCE BYP ASS GND 1 208V GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 13 2 13 2 13 4 L1 L2 N L1 +- Input Ext. battery Utility input L2 NOTE GMB12 models are supplied with an attach ed input power cord complete with L14-30 plug.
9 Connecting Maintenance Byp ass to UPSt ation GXT6000T - 240X 12 3 4 MAINTENANCE BYP ASS GND 1 240V GND 3 GND 2 Utility TB1 UPS output TB3 UPS input TB2 2 13 2 13 2 13 4 L1 L2 N L1 +- Input Ext. battery Utility input L2 NOTE GMB12 models are supplied with an attached input power cord complete with L14 -30 plug.
10 W ALL-MOUNT DIAGRAM D IAGRAM FOR A TT ACHING U NIT TO W ALL Use the following diagram, which sh ows the location and measurement s of factory-cut mounting slot s, when prepar ing to attach the GXT Maintenance Bypass to a wall. Liebert recommend s using 1/4-20 mounting scre ws.
11 HARDWIRE OUTPUT OPTION This product is intended to be inst alled by a qualified electrician only . 1. COMPLETEL Y R EMOVE ALL P OWER FROM THE FRAME. If the Ma inte nance Bypass is connected to the UPS, disconnect external battery sup ply . 2. Remove the en d cover plate to access th e terminal block (see Accessing ter minal block below).
12 OPERATING PROCEDURES S T ART-UP AND INITIALIZATION Follow these steps in or der to start up the GXT 6kV A UPS while connected to the Maintenance Byp ass. O N M AINTENANCE B YP ASS 1. Set the Maintenance Bypa ss switch (SW1) to UPS position. 2. Close (position I ) UPS Input switc h (SW2).
13 S PECIFICATIONS T ypical Tr ansfer T ime (to or from maintenance byp ass) < 6 milliseconds Input V oltage Nominal 208V AC or 240V AC T otal Current 30A max. Operating Ambient T emperature 0° to +40° C S t orage Ambie nt T em perature -20° to +60° C Dimensions, W x D x H, in (mm) 8.
.
.
The Comp any Behind the Product s With over a million installations around th e globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a c.
デバイスLiebert UPStation GXTの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Liebert UPStation GXTをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLiebert UPStation GXTの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Liebert UPStation GXTの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Liebert UPStation GXTで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Liebert UPStation GXTを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLiebert UPStation GXTの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Liebert UPStation GXTに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLiebert UPStation GXTデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。