LifeSourceメーカーUA-702の使用説明書/サービス説明書
ページ先へ移動 of 20
TM C ongratulations. Y ou have pur chased a LifeSour ce state-of-the-art blood pr essur e monitor , one of the most technologically advanced yet easy to use pr oducts available in the marketplace today . This LifeSour ce monitor is designed to make your daily r egimen useful, and convenient.
WHA T DISPLA Y SYMBOLS MEAN . . . . . . . . . . . . . . . . . . . . 3 MONITOR COMPONENTS . . . . . . . . . . . . . . . . . . . . . . . . . 4 HOW 702 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 BEFORE YOU ST ART . . . . . . . . .
Display Symbol Recommended Action Remain still and r efrain fr om talking; measur ement in pr ogr ess. Pr ess exhaust button to r elease air . Incr ease pr essurization by 30 mmHg to 40 mmHg and r epeat measur ement. Replace all batteries with new ones.
PRESSURE AND PULSE DISPLA Y AIR SOCKET CUFF CUFF BA TTERY COMP ARTMENT SYSTOLIC DIAST OLIC (PULSE) POWER DIGIT AL BLOOD PRESSURE MONITOR MEASURING PRESS EXHAUST RE-MEASURE BA TTER Y LOW RE-MEASURE UA-.
Y ou must install 4 type AA (1.5 volt) batteries and attach the cuff to the monitor befor e using it. T o install batteries (or r eplace them if the “Low Battery” symbol appears on display), pr oceed as follows: 1. Remove battery compartment cover by gently pushing down on arr ow and sliding cover forward.
Using the corr ect cuff size is impor tant for an accurate r eading. A cuff that is too lar ge will pr oduce a r eading that is lower than the corr ect blood pr essur e; a cuf f that is too small yields a measur ement that is higher .
T AKING YOUR BLOOD PRESSURE T ips for Blood Pr essur e Monitoring: ☞ Relax for about 5 to 10 minutes befor e measur ement. ☞ Remove constricting clothing and place cuff on bar e arm. ☞ Unless your physician r ecommends otherwise, use left arm to measur e pr essur e.
☞ IMPORT ANT : Measure pressure at the same time each day . 4. Pr ess the POWER button. 5. W atch for all display symbols to appear briefly , followed by a zer o, indicating that monitor is r eady for measur ement.
7. Sit quietly during measur ement. Pr essur e values ar e displayed at left, then right, along with ❤ symbol blinks and beeps with pulse beat. NOTE: If you wish to stop inflation at any time, press the exhaust valve to release air . 8. W ait for the long beep, indicating that the measurement is complete.
10. Remove cuff and make a note of your blood pr essur e and pulse rate on the chart (see page 16), indicating date and time of measur ement. W e advise that you r ecor d the date and time after each measur e- ment because an accurate blood pr essur e history r elies not on single or sporadic r eadings but on a pattern over time.
CHECK/ADJUST EXHAUST VELOCITY Exhaust velocity is the rate at which the air pr essur e in the cuf f deflates during the course of measur ement. It is pr eset at the factory and generally does not need any further adjustment. NOTE: The exhaust rate of your monitor was preset and tested at the factory to ensure proper measurement.
4. W atch the display screen. As pr essure automatically decr eases, diastolic numbers should decline in incr ements of 2 to 5 mmHg. If the exhaust velocity range is not within 2 to 5 mmHg, make the following adjustment with the unit turned off: 1. The adjustment scr ew is located on the exhaust valve attached to the inflator bulb.
What Is Blood Pressure? Blood pr essur e is the for ce exerted by blood against the walls of the arteries. Systolic pr essure occurs when the hear t contracts; diastolic pr essur e occurs when the hear t expands. Blood pr essur e is measur ed in millimeters of mer cury (mmHg).
Assessing High Blood Pressure The following standar ds for assessing high blood pr essur e (without r egar d to age) have been established by the National Institutes of Health JNCVI.
Why Measure Blood Pressure at Home? It is now well known that, for many individuals, blood pr essur e r eadings taken in a doctor’ s office or hospital setting might be elevated as a r esult of appr ehension and anxiety . This r esponse is commonly called “white coat hypertension.
EXAMPLE D A TE AM SYS/DIA PULSE PM SYS/DIA PULSE Name: Age: W eight: BLOOD PRESSURE RECORD 1/14 9:30 132/98 P 69 6:30 128/87 P 63 TM 16 ❤ LifeSource Health Line (T oll-Free): 1-888-726-9966.
Please r ead this important information befor e using your monitor . ☞ Please r emember that only a medical practitioner is qualified to interpr et your blood pr essur e measur ements. Use of this device should not r eplace r egular medical examinations.
Model . . . . . . . . . . . . . . . . . . .UA-702 T ype . . . . . . . . . . . . . . . . . . . . .Oscillometric Display . . . . . . . . . . . . . . . . . .Digital, 10-mm character height Pr essur e/pulse displayed alternately Measurement range . . . . .
Our pr oducts ar e designed and manufactur ed using the latest scientific and technological methods, and offer accurate, easy to use, home monitoring and tr eatment options.
CONT ACT INFORMA TION A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www .LifeSourceOnline.com LifeSour ce is a trademark of A&D Medical. ©2003 A&D Medical. All rights reserved. Specifications subject to change without notice.
デバイスLifeSource UA-702の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
LifeSource UA-702をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLifeSource UA-702の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。LifeSource UA-702の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。LifeSource UA-702で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
LifeSource UA-702を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLifeSource UA-702の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、LifeSource UA-702に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLifeSource UA-702デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。