Lincolnメーカー1162-080-Aの使用説明書/サービス説明書
ページ先へ移動 of 40
Imp2DigAdvServ REV 3/20/08 SERVICE MANUAL (DOMESTIC) IMPINGER CONVEYOR OVENS MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1, 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 2 SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, GAS (OVENS WITH PUSH BUTTON CONTROLS) MODEL 1116-080-A NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. 1 PHASE MODEL 1117-080-A LP GAS 120VAC 60 HZ.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 3 SEQUENCE OF OPERATION IMPINGER II ADVANTAGE, ELECTRIC (OVENS WITH PUSH BUTTON CONTROLS) 1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 4 SCHEMATIC DIAGRAM MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 5 SCHEMATIC DIAGRAM MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1 SCHEMATIC DIAGRAM.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 6 MODEL 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 7 SCHEMATIC DIAGRAM MODEL 1161-080-A.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 8 SCHEMATIC DIAGRAM MODEL 1162-080-A.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 9 SCHEMATIC DIAGRAM MODEL 1130-08H-A, 1131-08H-A.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 10 SCHEMATIC DIAGRAM MODEL 1132-08H-A, 1133-08H-A.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 11 TROUBLESHOOTING GUIDE GAS OVENS MODEL 1116-080-A NAT. GAS 120VAC 60 HZ. MODEL 1116-080-A1 NAT. GAS 120VAC 60 HZ. MODEL 1117-080-A LP GAS 120VAC 60 HZ. MODEL 1117-080-A1 LP GAS 120VAC 60 HZ.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 12 the main fan motor) to neutral. If no voltage is present, trace wiring back to the main power switch. If voltage is present, check for 120VAC at wire #22 (output of centrifugal switch) to neutral.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 13 occur. If flame is not detected, the ignition control will shut off and lock out. To reset the ignition control, turn off the power switch for 45 seconds, then turn the switch on to re-try ignition.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 14 Oven control If the thermoc ouple checks good, but the oven control display indicates that there is a therm ocouple failure, replace the oven control. If the oven control indicates a temperature reading but the oven wo n’t heat, proceed.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 15 needed. WARNING: Capacitor ha s a stored charge, discharge before testing. Switch, conveyor reversing Check continuity between swit ch terminals.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 16 1130-080-A 120/208VAC 60 HZ. 1 PHASE 1130-080-A1 120/208VAC 60 HZ. 1 PHASE 1130-08H-A 208 VAC 60 HZ. 1 PHASE 1131-080-A 120/240VAC 60 HZ. 1 PHASE 1131-080-A1 120/240VAC 60 HZ. 1 PHASE 1131-08H-A 240 VAC 60 HZ.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 17 Replace relay as needed. Main fan runs after 20 minute cool down Oven start relay Contacts should open whe n main power switch is turned off. Replace relay as needed. 20 Minute time delay 120VAC at terminal # 2 sh ould discontinue approx.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 18 If there is a read-out on the control, set the co ntrol to maximum temperature (see installation operations manual for temperature adju stment). With the control set at maximum temperature, check for supply voltage at mercury contactor.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 19 thermal protection and w ill cease to operate if overheating occurs. As the motor overheats and then cools, this will cause the oven to cycle on a nd off intermittently. Improper ventilation or lack of preventive maintenance may cause this.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 20 Conveyor motor If there is voltage supplied to the hall effect sensor, check for a frequency output fro m the hall effect sensor. Measure frequen cy across the yellow and white wires at the motor connecto r.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 21 CAPACITOR – REPLACEMENT A. Shut off power at main breaker. B. Remove rear control box cover. C. Discharge capacitor. D. Remove capacitor. E. Reassemble in reverse order and check system operation.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 22 F. Reassemble in reverse ord er and check system oper ation. Be sure capill ary tube is securely in the mount. NOTE: Push reset butt on on new thermostat. TRANSFORMER, BURNER – REPLACEMENT A.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 23 BURNER CONTROL – REPLACEMENT A. Shut off power at main breaker. B. Remove conveyor and front control box cover. C. Remove wires from control and mark for reassembly. D. Remove mounting screws from control and rem ove burner control.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 24 BYPASS ORIFICE – REPLACEMENT A. Shut off power at main breaker. B. Shut off gas supply to the oven and di sconnect the flexible gas line to oven. C. Remove rear control box cover.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 25 G. Turn adjusting screw on ai r pressure switch fully counter clockwi se. H. Turn oven “on”. I. Turn adjusting screw on air pressure switch clockwise until heat shuts off. J.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 26 GENERAL VIEW IMPINGER II ADVANTAGE MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1, 1130-080-A, 1130-080-A1, 1131-080-A,.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 27 GENERAL VIEW.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 28 CONTROL BOX, FRONT MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 LETTER PART NUMBER DESCRIPTION A 369805 Switch, on/of.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 29 CONTROL BOX, FRONT VIEW MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 30 CONTROL BOX, FRONT MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130-08H-A, 1131-08H-A, 1132-08H-A, 1133-08H-A, 1161-080-A, 1162-080-A LETTER PART NUMBER DESCRIPTION A 369680 Front cover assy.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 31 CONTROL BOX, FRONT VIEW MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 32 CONTROL BOX, REAR MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1 LETTER PART NUMBER DESCRIPTION A 369192 Capacitor B 370378 Conveyor motor assy. (S/N 2052462 & Below) 370675 Conveyor motor as sy.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 33 CONTROL BOX, REAR VIEW MODEL 1116-080-A, 1116-080-A1, 1117-080-A, 1117-080-A1.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 34 CONTROL BOX REAR MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1, 1130.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 35 CONTROL BOX, REAR VIEW MODEL 1130-080-A, 1130-080-A1, 1131-080-A, 1131-080-A1, 1132-080-A, 1132-080-A1, 1133-080-A, 1133-080-A1.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 36 OVEN BACK ASSEMBLY LETTER PART NUMBER DESCRIPTION A 369182 Fan B 369899 Fan shroud C 369655 Stand off D Heating element 369183 .
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 37 OVEN BACK ASSEMBLY VIEW.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 38 CONVEYOR / DOOR LETTER PART NUMBER DESCRIPTION A 369190 Coupler (S/N 2052462 & below) 370671 Coupler (S/N 2052463 & abo.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 39 CONVEYOR / DOOR VIEW.
Impinger II – Advantage Digital Expr ess Service Manual - Dom estic 40.
デバイスLincoln 1162-080-Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln 1162-080-Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln 1162-080-Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln 1162-080-Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln 1162-080-Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln 1162-080-Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln 1162-080-Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln 1162-080-Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln 1162-080-Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。