Ranger ® 305D (CE) OPERA T ORʼS MANUAL IM971-A June, 2010 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thoughtful operation on your part.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
iii SAFETY iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8 . b . Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturerʼs recommendations.
iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A LʼArc 1.
v SAFETY v .
vi SAFETY vi THE LINCOLN ELECTRIC COMPANY EC DECLARATION OF CONFORMITY Manufacturer and technical docum entation holder: The Lincoln Electric Company Address: 22801 St.
vii SAFETY vii Electromagnetic Compatibility (EMC) Conformance Products displaying the CE mark are in conformity with European Community Council Directive of 15 Dec 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility, 2004/108/EC.
viii SAFETY viii Electromagnetic Compatibility (EMC) The size of the surrounding area to be considered will depend on the structure of the building and other activities that are taking place. The surrounding area may extend beyond the boundaries of the premises.
ix ix Thank Y ou for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
x x T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .......................................................
xi xi T ABLE OF CONTENTS Maintenance ......................................................................................................Section D Safety Precautions ...................................................................................
RANGER® 305D (CE) (1) Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity. When welding, available auxiliary power will be reduced. (2) To top of enclosure, add 152mm (6 “) to top of exhaust elbow.
LIFTING The machine weighs approximately 374 kg. (824 lbs) with a full tank of fuel. A lift bail is mounted to the machine and should always be used when lifting the machine. HIGH ALTITUDE OPERATION At higher altitudes, output derating may be necessary.
A-3 INST ALLA TION RANGER® 305D (CE) A-3 TOWING Check with distributor for the recommended trailer for use with this equipment for road, in-plant and yard towing by a vehicle.
A-4 INST ALLA TION RANGER® 305D (CE) A-4 ENGINE COOLING SYSTEM Air to cool the engine is drawn in the base sides and exhaust through radiator & case back. It is important that the intake and exhaust air is not restricted. Allow a minimum clearance of 0.
CABLE INSTALLATION Install the welding cables to your machine as follows: 1. The diesel engine must be OFF to install welding cables. 2. Remove the flanged nuts from the output termi- nals. 3. Connect the electrode holder and work cables to the weld output terminals.
A-6 INST ALLA TION RANGER 305D (CE) A-6 Connection of the LN-25 to the RANGER® 305D (CE). Shut off welder before making any electrical con- nections. ------------------------------------------------------------------------ The LN-25 with or without an internal contactor may be used with the RANGER® 305D (CE).
A-7 INST ALLA TION RANGER® 305D (CE) A-7 Connection of LN-742 and Cobramatic to RANGER® 305D (CE). • Shut the welder off. • Connect per instructions on the appropriate connec- tion diagram in Section F.
B-1 OPERA TION RANGER® 305D (CE) B-1 SAFETY PRECAUTIONS Do not attempt to use this equipment until you have thoroughly read the engine manufacturerʼs manual supplied with your welder. It includes important safety precautions, detailed engine starting, operating and maintenance instructions, and parts lists.
B-2 OPERA TION B-2 WELDING CONTROLS (Figure B.1) 1. OUTPUT CONTROL: The OUTPUT dial is used to pre- set the output voltage or current as displayed on the digi- tal meters for the four welding modes.
B-3 OPERA TION B-3 4. ARC CONTROL : The ARC CONTROL dial is active in the CV-WIRE, CC-STICK and DOWNHILL PIPE modes, and has different functions in these modes.
B-4 OPERA TION B-4 15. ELECTRIC FUEL GAUGE- Provides accu- rate, reliable indication of how much fuel is in the tank. . 16. ENGINE HOUR METER – Displays the total time that the engine has been running. This meter is useful for scheduling prescribed maintenance.
TYPICAL CURRENT RANGES (1) FOR TUNGSTEN ELECTRODES (2) Tungsten Electrode DCEN (-) DCEP (+) Approximate Argon Gas Flow TIG TORC H Diameter in. (mm) Flow Rate C.F.H. ( l /min.) Nozzle Size (4), (5) 1%, 2% Thoriated 1%, 2% Thoriated Aluminum Stainless Steel Tungsten Tungsten .
AUXILIAR Y POWER: Start the engine and set the IDLER control switch to the desired operating mode. Full power is available regardless of the welding control settings providing no welding current is being drawn. Simultaneous Welding and Auxiliary Power Loads While welding, the amount of 3-phase Auxiliary power available is reduced.
C-1 ACCESSORIES C-1 FIELD INST ALLED OPTIONS / ACCESSORIES K704 ACCESSORY SET - Includes (10m) 35 ft. of electrode cable and (9.m) 30 ft. of work cable, head- shield, work clamp electrode holder. Cables are rated at 400 amps, 100% duty cycle. K857 (7.
D-1 MAINTENANCE D-1 RANGER® 305D (CE) SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • Turn the engine off before working inside the machine or servicing the engine. • Remove guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is complete.
D-2 MAINTENANCE D-2 ENGINE OIL CHANGE Drain the engine oil while the engine is warm to assure rapid and complete draining. It is recommended that each time the oil is changed the oil filter be changed as well. • Be sure the unit is off. Disconnect the negative bat- tery cable to ensure safety.
D-3 MAINTENANCE D-3 RANGER® 305D (CE).
D-4 MAINTENANCE D-4 COOLING SYSTEM HOT COOLANT can burn skin. • Do not remove cap if radiator is hot. ------------------------------------------------------------------------ Check the coolant level by observing the level in the radiator and recovery bottle.
D-5 MAINTENANCE D-5 FUEL FIL TER 1. Check the fuel filter and fuel pre-filter for water accu- mulation or sediment. 2. Replace the fuel filter if it is found with excessive water accumulation or sediment.
D-6 MAINTENANCE D-6 RANGER® 305D (CE) WELDER / GENERA T OR MAINTENANCE STORAGE: Store the RANGER® 305D (CE) in clean, dry protected areas. CLEANING: Blow out the generator and controls peri- odically with low pressure air. Do this at least once a week in particularly dirty areas.
E-1 TROUBLESHOOTING E-1 RANGER® 305D (CE) If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 RANGER® 305D (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TROUBLESHOOTING E-3 RANGER® 305D (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING E-4 RANGER® 305D (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-5 TROUBLESHOOTING E-5 RANGER® 305D (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-6 TROUBLESHOOTING E-6 RANGER® 305D (CE) Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIAGRAMS F-1 RANGER® 305D (CE).
F-2 DIAGRAMS F-2 RANGER® 305D (CE).
F-3 DIAGRAMS F-3 RANGER® 305D (CE).
F-4 DIAGRAMS F-4 RANGER® 305D (CE).
F-5 DIAGRAMS F-5 RANGER® 305D (CE).
F-6 DIAGRAMS F-6 RANGER® 305D (CE) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-7 DIAGRAMS F-7 RANGER® 305D (CE) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-8 DIMENSION PRINT F-8 RANGER® 305D (CE) A M21086 60.21 1529.3 29.67 753.6 60.00 1524.0 59.20 1503.7 17.50 444.5 19.50 495.3 21.06 534.9 21.50 546.1 29.83 757.6 34.24 869.8 11.03 280.2 29.63 752.6 17.00 431.8 CEN TER O F GRA VITY 35.08 891.03 26.52 673.
NOTES RANGER® 305D (CE).
NOTES RANGER® 305D (CE).
NOTES RANGER® 305D (CE).
W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A T E N ÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF A CTURER’S INSTR UCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLL O W Y OUR EMPL O YER’S SAFETY PR A CTICES.
W ARNING A VISO DE PREC A UCION A TTENTION W ARNUNG A T E N ÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREEND A A S INSTR UÇÕES DO F ABRIC ANTE P ARA ES TE EQUIP AMENT O E AS P ARTES DE USO , E SIG A A S PRÁ TIC A S DE SEGUR ANÇ A DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric 11458の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric 11458をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric 11458の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric 11458の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric 11458で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric 11458を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric 11458の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric 11458に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric 11458デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。