Lincoln Electricメーカー4.1の使用説明書/サービス説明書
ページ先へ移動 of 20
E LF A 3. 1 & 4. 1 Fume Extraction Arms OPERA TOR’S MANUAL Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi T ABLE OF CONTENTS Page Safety ....................................................................................................................................... i-iv Installation ...............................................................
500 750 4 6 0 250 1000 2 0 Air Flow (CFM) Vacuum (Inches WG) SF 2400 LTA 3.1/4.1 PRESSURE DROP - SF2400 F an and LF A 3.1/4.1 Arms LFA 3.1 & 4.1 FUME EXTRACTION ARMS A-1 INST ALLA TION A-1 T echnical Specifications- LF A 3.1 & 4.1 Fume Extraction Arms NOTE: Technical Specifications are subject to change without prior notice.
If installing the arm on a Mobiflex 200-M , refer to the Mobiflex 200-M manual for installation information. If installing the arm on a Mobifle x 400-MS , refer to the Mobiflex 400-MS manual for installation information.
A-3 INST ALLA TION LFA 3.1 & 4.1 FUME EXTRACTION ARMS A-3 INST ALLING THE LF A 3.1 OR 4.1 ARM ON A W ALL MOUNTING BRA CKET Only qualified personnel should install, use or service this equipment.
Rotate the hinge rod (Fig. 4, Item D) so the stop pin (Fig. 4, Item B) is in the front. Mount the hanging adapter (Fig. 5, Item D) to the hinge rod using (2) 1.75 ” bolts with washers and nuts. Mount the spring bracket (Fig. 5, Item F) into the two holes as shown.
INST ALLING THE LF A 3.1 OR 4.1 ARM ON A W ALL MOUNTING BRA CKET (continued) MOUNTING THE LFA 3.1 OR 4.1 ARM TO THE WALL-MOUNTING BRACKET (continued) Position one 8 ” rubber band (Fig. 7, Item B) and the flexible hose supplied with the arm (Fig. 7, Item C) on the hood end of the arm (Fig.
B-1 OPERA TION B-1 Read and understand this entire section before oper- ating your LFA 3.1 or 4.1 Extraction Arm. SAFETY INSTR UCTIONS Do not attempt to use this equipment until you have thoroughly read all operating and maintenance man- uals supplied with your equipment and any related welding machine it will be used with.
R OUTINE MAINTENANCE Every 3 months, check the integrity of the outside of the extraction arm and clean it with a non-agressive detergent. Every 12 months: • Check the flexible hoses and rubber seals for cracks or damage; replace if necessary. • Check the inside of the extraction arm and clean it thoroughly.
D-1 TR OUBLESHOO TING D-1 LFA 3.1 & 4.1 FUME EXTRACTION ARMS Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable.
NO TES X-TRACTOR 1GC.
Now A vailab le...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “ Bible ” of the arc welding industry. This printing will go fast so don ’ t delay.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric 4.1の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric 4.1をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric 4.1の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric 4.1の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric 4.1で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric 4.1を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric 4.1の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric 4.1に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric 4.1デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。