Lincoln ElectricメーカーDC-400の使用説明書/サービス説明書
ページ先へ移動 of 42
RED-D-ARC DC-400 IM655-B November, 2006 Red-D-Ar c Spec-Built W elding Equipment This RED-D-ARC welder is built to RED-D-ARC Extreme Duty design specifications by Lincoln Electric. Safety Depends on Y ou This welder is designed and built with safety in mind.
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product. We want you to take pride in operating this product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick reference.
vi vi T ABLE OF CONTENTS Page Installation .. .......................................................................................................Section A Technical Specifications ...................................................................
vii T ABLE OF CONTENTS Page Maintenance ... ....................................................................................................Section D Safety Precautions ..............................................................................
A-1 INST ALLA TION DC-400 A-1 TECHNICAL SPECIFICA TIONS – DC-400 Standard Input Current at Rated Output (CVI) Voltage 100 % Duty Cycle 60 % Duty Cycle (4) 50 % Duty Cycle Frequency 230/460/575V/60Hz 400Amps/36V 450Amps/38V 500Amps/40V 78/39/31Amps 83/42/33Amps 84/42/34Amps INPUT -THREE PHASE ONL Y RA TED OUTPUT HEIGHT WIDTH DEPTH WEIGHT 27.
A-2 INST ALLA TION DC-400 A-2 SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrodes with your skin or wet clothing. • Insulate yourself from the work and ground.
A-3 INST ALLA TION DC-400 A-3 REMOTE CONTROL ADAPTER CABLE (K864) A “V” cable 12” (.30m) long to connect a K857 Remote Control, K963 Hand Amptrol or K870 Foot Amptrol (6-pin connector) with a wire-feeder (14-pin connector) and the machine (14-pin connector).
A-4 INST ALLA TION DC-400 A-4 HI-FREQUENCY KIT (K799 CODES 8634 AND ABOVE ONL Y) Kit supplies the high frequency plus gas valve for DC TIG welding. The DC-400 is shipped with proper R.F. bypass circuitry installed to protect the control circuit when welding with a HI-FREQ unit.
A-5 INST ALLA TION DC-400 A-5 CONNECTION OF DC-400 TO LN-22 OR LN-25 a) Turn off all power. b) Place output terminals switch into the “ ON ” posi- tion. c) Connect the electrode cable to the output terminal of polarity required by electrode. Connect the work lead to the other terminal.
A-6 INST ALLA TION DC-400 A-6 AUXILIARY POWER CONNECTIONS The power source is equipped to furnish nominally 110-115 volt AC and 40-42 volt AC auxiliary power for operating wire feeding equipment, etc.
A-7 INST ALLA TION DC-400 A-7 The individual case sides are removable for easy access for internal service or inspection. The case rear, top section, is equipped with a remov- able access panel. This provides easy access to the input contactor, easy connection and reconnection of input leads, and easy access for service or inspection.
A-8 INST ALLA TION DC-400 A-8 To change stick polarity, reverse the leads at the (+) and (-) terminals on the right side of the Multiprocess Switch. NOTE: When a DC-400 equipped with Multiprocess Switch is mounted on an undercarriage, the undercarriage handle in the resting position can hit the case of the Multiprocess Switch.
B-1 OPERA TION DC-400 B-1 SAFETY PRECAUTIONS Read this entire section of operating instructions before operating the machine. ELECTRIC SHOCK can kill. • Have an electrician install and ser- vice this equipment. • Turn the input power off at the fuse box before working on equipment.
DC-400 B-2 OPERA TION B-2 Gas Metal Arc Welding ARC CONTROL SWITCH Increase/Decrease of Inductance Low Inductance High Inductance Output (Voltage) OUTPUT TERMINALS SWITCH On Remote On/Off Shielded Met.
DC-400 B-3 OPERA TION B-3 RATING PLATE (Continued) Transformer Constant Current Characteristic Submerged Arc Welding Rectifier Rectified DC Output Constant Voltage Characteristic Line Connection Shielded Metal Arc Welding Designates Welder can be used in environments with increased hazard of electric shock.
DC-400 B-4 OPERA TION B-4 Do not switch if output voltage or current is present. MODE SWITCH Warning Identification WARNING IDENTIFICATION Signifying the Earth (Ground) Connection EARTH GROUND CONNECTION Constant Voltage (Submerged Arc Welding) Constant Voltage (Flux cored arc welding, gas metal arc welding).
B-5 OPERA TION B-5 GENERAL MACHINE DESCRIPTION The DC-400 is an SCR controlled three phase DC power source. It is designed with a single range potentiometer control.
B-6 OPERA TION B-6 POWER SOURCE OPERA TION Duty Cycle and Time Period The DC-400 is rated at the following duty cycles: * Based upon 10 minute time period (i.
B-7 OPERA TION B-7 In this position, the dynamic characteristics of the machine under welding conditions provide optimum welding characteristics for Innershield ® welding, other open arc processes including short arc MIG welding, and air carbon arc. Most submerged arc welding can also be done in this mode.
B-8 OPERA TION B-8 T erminal Strip Connections Terminal strip TS2 located behind the hinged control panel on the front of the power source supplies 110-115V AC. A 15 amp circuit breaker protects this circuit. Note that this 110-115V AC is also available in the 14-pin connector on the Domestic and Export models.
C-1 ACCESSORIES C-1 Factory Installed Options DIODE OPTION This internally installed option allows the use of the cold start and cold electrode sensing features of the NA-3, NA-5 or NA-5R. MULTIPROCESS SWITCH Factory or field installed kit that mounts on the front of the DC-400, and includes hinged covers over its out- put studs.
C-2 ACCESSORIES C-2 HI-FREQUENCY KIT (K799 CODES 8634 AND ABOVE ONLY) Kit supplies the high frequency plus gas valve for DC TIG welding. The DC-400 is shipped with proper R.F. bypass circuitry installed to protect the control circuit when welding with a HI-FREQ unit.
DC-400 D-1 MAINTENANCE D-1 Routine Maintenance 1. The fan motor has sealed bearings which require no service. 2. In extremely dusty locations, dirt may clog the air channels causing the welder to run hot. Blow out the machine at regular intervals. 3. In extremely dusty locations, dirt may accumulate on the remote control terminal strip TS1.
DC-400 E-1 TROUBLESHOOTING E-1 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 Observe all Safety Guidelines detailed throughout this manual PROBLEMS (SYMPTOMS) POSSIBLE CAUSE RECOMMENDED COURSE OF ACTION Input contactor (CR1) chatters. Machine input contactor does not operate. Machine input contactor operates, but no output when trying to weld.
E-3 TROUBLESHOOTING E-3 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-4 TROUBLESHOOTING E-4 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
DC-400 E-5 TROUBLESHOOTING E-5 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
DC-400 E-6 TROUBLESHOOTING E-6 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
F-1 DIAGRAMS F-1 DC-400 L9107 13 14 15 16 17 18 H2 H3 H4 ELECTRICAL SYMBOLS PER E1537 CONNECTOR CAVITY NUMBERING SEQUENCE (COMPONENT SIDE OF P.C. BOARD) NOTES N.
F-2 DIAGRAMS F-2 DC-400 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-3 DIAGRAMS F-3 DC-400 NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
F-4 DIAGRAMS F-4 DC-400 POWER RECTIFIER BRIDGE DIAGRAM 1 PLUG TO SNUBBER BOARD SHUNT P5 221 222 223 204 220 204 204 204 204 220 D1 D2 D3 SCR1 SCR2 SCR3 G1 G2 G3 D4 ANODE CATHODE ANODE CATHODE P3 Gate leads plug to control P.
F-5 DIMENSION PRINT F-5 DC-400 Part No. Type ABCD F G H M12244-7 DC-400 32.00 15.39 30.92 1.44 30.02 + .11 30.02 + .11 .94.
DC-400 NOTES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric DC-400の購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric DC-400をまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric DC-400の技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric DC-400の取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric DC-400で得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric DC-400を既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric DC-400の不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric DC-400に関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric DC-400デバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。