Lincoln ElectricメーカーIM491-Bの使用説明書/サービス説明書
ページ先へ移動 of 40
PRO-CUT 1 25 PLASMA CUTTING PO WER SOURCE OPERA TOR’S MANUAL For use with machines having Code Numbers 10384 thru 10388 IM491-B October,1999 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
– 2 – PROTECT YOURSELF AND OTHERS FROM POSSIBLE SERIOUS INJURY OR DEATH. KEEP CHILDREN AWAY. PACEMAKER WEARERS SHOULD CONSULT WITH THEIR DOCTOR BEFORE OPERATING.
– 3 – FOR ELECTRICALL Y powered equipment. 6.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 6.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s rec- ommendations.
– 4 – PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
– 5 – TABLE OF CONTENTS Page Safety Precautions ............................................................................................................. 2-4 Introductory Information ............................................................
– 6 – Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
– 7 – SPECIFICA TIONS Type K1394-* and K1395-* K880-1[25Ft.(7.6m)Cable] & K880-2 [50Ft.(15.2m)Cable] Magnum PCT125 Air Cooled Torch Input Frequency 50 or 60 Hz, 3ø Output Rating 125 Amps, 148.
PR ODUCT DESCRIPTION The PRO-CUT™ 125 is a constant current, single range, continuous control plasma cutting system. The system is one of the most sophisticated on the market. It provides excellent starting characteristics, cutting visibility and arc stability.
INST ALLA TION SAFETY PRECA UTIONS ● Read the safety precautions at the beginning of this Operator's Manual before proceeding. ● Only personnel that have read and under- stood this Operating Manual should install and operate this equipment.
Input Voltage / Hz. 230/60 460/60 220/50/60 380/50/60 440/50/60 3 Input Wires #3 (25mm 2 ) #8 (10mm 2 ) #3 (25mm 2 ) #6 (16mm 2 ) #8 (10mm 2 ) 1 Grounding Wire #8 (10mm 2 ) #8 (10mm 2 ) #8 (10mm 2 ) #.
AIR INPUT CONNECTIONS A source of clean compressed air or nitrogen must be supplied to the PRO-CUT. The supply pressure must be between 80 and 150 psi (551 and 1034 kPa). The flow rate is approximately 8.0 cfm. Oil in the air is a very severe problem and must be avoided.
F. When ready to cut, place the work lead on the piece to be cut, place the torch near the work, make certain all safety precautions have been taken and pull the trigger. -The air will flow for a preflow time of 2 seconds and the pilot arc will start.
Expanded Metal: Output set near mid-range. • Cut it as you would light gauge sheet metal. • Expanded metal is pilot arc intensive. After about 30 seconds of cutting, the pilot arc will change from a bright continuous arc to a discon- tinuous one which will sputter slightly.
In All Cases: • Do not pause when cutting or gouging the metal. This is not necessary and causes opera- tional difficulty. Pausing at the edge of the work- piece causes poor consumable life and erratic operation. • Always position the torch in the best way to keep dross and hot air from burning back into it.
MAINTENANCE PR OCEDURES R OUTINE MAINTENANCE 1. Keep the cutting or gouging area and the area around the machine clean and free of com- bustible materials. No debris should be allowed to collect which could obstruct air flow to the machine. 2 . Every few months, blow the dust off the air intakes and louvers with compressed air.
– 16 – SYMPTOM CHECK No LED’s light when the power switch is turned on. 1. Check the input power to be sure it is on. 2. Check the power line fuses and machine connection. 3. Replace line switch. The “MACHINE ON” LED is lit, but there is no 1.
– 17 – SYMPTOM CHECK The air begins to flow, the “OUTPUT ON” LED lights 1. Check the torch consumables to be sure they for a brief period, but no arc is established. are in tight, not dirty or greasy, and in good shape. Replace the consumables if necessary.
– 18 – SYMPTOM CHECK The “MALFUNCTION” LED is lit. 1. The FAULT circuit monitors the torch to see if it is shorted as well as internal machine failures. 2. Check the torch consumables to see if they are melted together or are simply touching each other.
– 19 – SYMPTOM CHECK The “SAFETY” LED is lit. 1. The machine will not operate. The machine senses that the shield cup is not in place, or the operators could be exposed to dangerous voltages if the machine were allowed to operate. 2. Check the shield cup to be sure it is tightly in place.
– 20 – STATUS LIGHTS CONDITION SUGGESTIONS MACHINE ON Should always be on when machine is on. Normal OUTPUT ON On when there is voltage potential at the Normal torch (cutting or pilot). OUTPUT ON is blinking alternately with AIR PRESSURE when power is first There is a problem with the microprocessor, applied to machine.
– 21 – STATUS LIGHTS CONDITION SUGGESTIONS SAFETY It is possible that this light could turn on If machine can be reset, it is OK to continue when power is first applied to machine. operation. The torch assembly is misconnected or Check torch connection to machine.
– 22 – PROCEDURE FOR REPLA CING PC BO ARDS Before replacing a PC board which is suspected of being defective, visually inspect the PC board in ques- tion for any damage to any of its components and conductors on the back of the board. If there is no visible damage to the PC board, install a new one and see if this remedies the problem.
– 23 – NO TES.
– 24 – PCT 125 AMP PLASMA TORCH 2-10-92 Parts List P-210-C 1 7 6 12 5 9 4 11 13 10 2 2 3.
– 25 – PCT 125 AMP PLASMA TORCH Parts List P-210-C.1 Mag PCT-125 Torch & Cable (25’) K880-1 1 Mag PCT-125 Torch & Cable (50’) K880-2 1 1 Cable Asbly (25’) L9371-1 1 1 Cable Asbly (50’) L9371-2 1 2 Handle Repair Kit S21087 1 * Handle (LH), Includes: Handle Nut S18773 4 * Handle (RH), Includes: Pan Handle Screw (#6-32 x .
– 26 – GENERAL ASSEMBL Y PRO-CUT 125 THREE PHASE Parts List P-207-C Drop in photos from P-207-C parts page..
– 27 – GENERAL ASSEMBL Y PRO-CUT 125 THREE PHASE Parts List P-207-C.1 1 Base L8473 1 2 Base Support L8472 1 3 Foot L8284 1 * Thread Forming Screw S9225-26 8 * Caster S11124-8 2 * Thread Forming Sc.
– 28 – CASE BACK ASSEMBL Y Parts List P-207-D 1-7-92 L8348 5-28-93 1 2 3 4 6 5 1 Case Back L7753-1 1 2 Fan & Baffle Asbly, Includes: M15585 1 * Fan Baffle L7666 1 * Fan Blade M8678-2 1 * Fan M.
– 29 – SOLENOID ASSEMBL Y Parts List P-207-E S18667-5 1 2 3 4 5 10 7 8 9 1 Hose Nipple (Male) T14557-11 1 2 Solenoid S18127-4 1 3 Pipe Tee T10366 1 4 Pressure Switch S18638-1 1 5 PC Board Plug S14156-1 1 8 Hex Nipple T11289-3 1 9 Male Run Tee S19932-1 1 10 Solenoid S18127-5 1 Part No.
– 30 – REGULA TOR AND FIL TER ASSEMBL Y 1 2 3 4 IN 6 8 9 10 Parts List P-184-E 1 Filter/Regulator Asbly M16480 1 * Filter Element (.50 ID x 1.14” Long) M16480-B 1 * Panel Mounting Nut M16480-C 1 2 Oil/Coalescing Filter S19865 1 * Filter Element (.
– 31 – INPUT BOX ASSEMBL Y Parts List P-207-F L8322-1 6-12-96 AC2 AC1 L1 L2 L3 L1 L2 L3 5 14 7 1 2 4 CR2 19 CR1 18 6 W V U REAR VIEW FRONT VIEW AC3 20 T2 T1 T3 17 21 1 Input Box L8285 1 2 Heat Sin.
– 32 – HI FREQ BOARD ASSEMBL Y Parts List P-207-G 6-12-96 L9320 6-12-96 1 3 2 10 12 6 PILOT WORK 14 18 17 20 1 Mounting Board Asbly S19700 1 2 Carriage Bolt T11827-23 1 * Hex Nut 1/4-20 2 * Brass .
– 33 – CASE FRONT ASSEMBL Y Parts List P-184-D 2-5-93 L7713 5-28-93C 1 2 3 4 5 6 9 7 8 12 13 1 Case Front G1873-1 1 2 Nameplate (Domestic) L8315 1 2 Nameplate (Export) L8354 1 3 PC Board Asbly M16.
– 34 – FIGURE 1- SINGLE VOL T AGE FIGURE 1- DUAL & TRIPLE VOL T AGE 3. REMOVE HEX NUTS AND POSITION LINKS AS SHOWN. REPLACE AND TIGHTEN ALL HEX NUTS. NOTE: MACHINES ARE SHIPPED FROM FACTORY CONNECTED THE LINCOLN ELECTRIC CO., CLEVELAND, OHIO U.
– 35 – FIGURE 2 ELECTRIC TORCHES Do not operate with covers removed Disconnect input power before servicing Do not touch electrically live parts Only qualified persons should install, use or service this equipment THE LINCOLN ELECTRIC CO. CLEVELAND, OHIO U.
– 36 – STATUS BOARD 1 2 3 4 5 6 8 7 211 212 213 214 215 216 218 325 326 1 3 2 R1 10K 5 4 1 2 6 3 5 6 3 7 84 9 2 J2 J8 1 CONTROL BOARD 12 14 10 11 15 16 13 10 1 2 3 4 5 6 7 8 9 319 324 323 322 321 .
– 37 – Now A v ailable...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “Bible” of the arc welding industry. This printing will go fast so don’t delay.
– 38 – W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
– 39 – W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS PAR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric IM491-Bの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric IM491-Bをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric IM491-Bの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric IM491-Bの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric IM491-Bで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric IM491-Bを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric IM491-Bの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric IM491-Bに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric IM491-Bデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。