Lincoln ElectricメーカーIM514-Aの使用説明書/サービス説明書
ページ先へ移動 of 30
OPERA TOR’S MANUAL Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
LINCOLN ELECTRIC ELECTRIC ® ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87.
LINCOLN ELECTRIC ELECTRIC ® FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
LINCOLN ELECTRIC ELECTRIC ® iv SAFETY iv PRÉCA UTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1.
Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi MASTER T ABLE OF CONTENTS FOR ALL SECTIONS Page Installation .......................................................................................................Section A Technical Specifications .................................................
A-1 INST ALLA TION CLASSIC I A-1 LINCOLN ELECTRIC ELECTRIC ® TECHNICAL SPECIFICA TIONS – CLASSIC I Product Name Description Horsepower Operating Speeds Displacement Ignition Capacities Continental TM27 4 Cylinder 4 Cycle Water-Cooled Gasoline Engine 38 HP @ 1450 RPM Full Load: 1450 RPM High Idle: 1600±50 RPM Low Idle: 1000 RPM 164.
A-2 INST ALLA TION CLASSIC I A-2 GENERAL DESCRIPTION The Classic I is a heavy duty engine driven DC arc welding power source capable of providing DC con- stant current output for stick welding and DC TIG welding.
A-3 INST ALLA TION CLASSIC I A-3 LINCOLN ELECTRIC ELECTRIC ® PRE-OPERA TION INST ALLA TION Safety Precautions Exhaust Spark Arrester Some federal, state, or local laws may require that engines be equipped with exhaust spark arresters when they are operated in certain locations where unarrested sparks may present a fire hazard.
A-4 INST ALLA TION CLASSIC I A-4 LINCOLN ELECTRIC ELECTRIC ® P olarity Control and Cable Sizes With the engine off, route the electrode and work cables through the strain relief bracket on the base and connect to the studs located below the fuel tank mounting rail.
A-5 INST ALLA TION CLASSIC I A-5 LINCOLN ELECTRIC ELECTRIC ® PRE-OPERA TION SER VICE READ the engine operating and maintenance instruc- tions supplied with this machine. ------------------------------------------------------------ Oil This unit is supplied from the factory with the engine crankcase filled with a high quality SAE 10W/30 oil.
B-1 OPERA TION B-1 CLASSIC I ENGINE OPERA TION Operate the welder with the doors closed. Leaving the doors open changes the designed air flow and can cause overheating. Starting the Continental TM27 Engine a) Turn the Idler control switch to “HIGH”.
B-2 OPERA TION B-2 CLASSIC I Control of W elding Current DO NOT TURN THE “CURRENT RANGE SELEC- TOR” WHILE WELDING because the current may arc between the contacts and damage the switch. ------------------------------------------------------------------------ The “Current Range Selector” provides five overlap- ping current ranges.
B-3 OPERA TION B-3 CARBURET OR DEICING KIT USA GE INSTR UCTIONS FOR SEA- SONAL CHANGE O VER ELECTRIC SHOCK can kill. • Do not operate with panels open. • Disconnect NEGATIVE(-) BATTERY LEAD before servicing. • Do not touch electrically live parts.
C-1 A CCESSORIES C-1 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® OPTIONAL FEA TURES (field Installed) Accessory Set (K702) Includes 35 ft (10.7m) electrode and 30 ft (9.1m) work cables, headshield, work clamp, and electrode holder. CV Adapter (K384) K6090 thru -4 only Provides constant voltage output for semiautomatic welding.
D-1 MAINTENANCE D-1 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® MAINTENANCE General Instructions 1. Blow out the welder and controls with an air hose at least once every two months. In particularly dirty locations, this cleaning may be necessary once a week.
D-2 MAINTENANCE D-2 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Bearings This welder is equipped with a double-shielded ball bearing having sufficient grease to last indefinitely under normal service. Where the welder is used con- stantly or in excessively dirty locations, it may be nec- essary to add one-half ounce of grease per year.
E-1 TR OUBLESHOO TING E-1 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TR OUBLESHOO TING E-2 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable .
E-3 TR OUBLESHOO TING E-3 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable .
E-4 TR OUBLESHOO TING E-4 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable .
E-5 TR OUBLESHOO TING E-5 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® Observe all Safety Guidelines detailed througout this manual If for any reason you do not understand the test procedures or are unable .
E-6 TR OUBLESHOO TING E-6 CLASSIC I LINCOLN ELECTRIC ELECTRIC ® ELECTR ONIC IDLER TROUBLESHOO TING GUIDE Engine Will Not Return to Idle in Approximately 15 Seconds Set Idler Control Switch to the Auto Position Check to See Whether Oil Pressure Light is On and Alternator is Charging Light Off Light On If Oil Light is O.
F-1 DIA GRAMS F-1 CLASSIC I MOTOR + GROUND GROUND TO BASE TO ENGINE EXC ALTERNATOR S B + STARTING OIL PRESSURE SWITCH G AUX POWER RECEPTACLE 600B B R TO EXCITER OUTPUT - + E E B F1 15A. TO PLUGS IGNITION COIL DISTRIBUTOR + - ONLY. FUSE IN CIRCUIT ON C.
F-2 DIA GRAMS F-2 CLASSIC I PART NO. WELDER A B C D E F G H A CONTROL PANEL F G B H D E C O HOLE O MOUNTING HOLE N.A. N.B. NOTES: OIL AND WATER IN ENGINE, BUT NO FUEL. N.A. CENTER OF GRAVITY WITH O S10766-7 J J K K DIMENSION PRINT S10766 METRIC cm (ENGLISH in.
Now A vailab le...12th Edition The Procedure Handbook of Ar c W elding With over 500,000 copies of previous editions published since 1933, the Procedure Handbook is considered by many to be the “Bible” of the arc welding industry. This printing will go fast so don’t delay.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECA UCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIP AMENTO E AS P AR TES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric IM514-Aの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric IM514-Aをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric IM514-Aの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric IM514-Aの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric IM514-Aで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric IM514-Aを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric IM514-Aの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric IM514-Aに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric IM514-Aデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。