Lincoln ElectricメーカーIM530-Cの使用説明書/サービス説明書
ページ先へ移動 of 40
W eldanpo w er 125 OPERA TOR’S MANUAL For use with Equipment having Code Numbers : 10158, 10160, 11183, 11406 IM530-C September, 2006 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv SAFETY iv Mar. ‘93 PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
T ABLE OF CONTENTS Page Safety .....................................................................................................................i-iv Installation .....................................................................................
INST ALLA TION TECHNICAL SPECIFICA TIONS - WELDANPOWER 125 Duty Cycle 30% 60% Amps 125 amps DC Constant Current 100 amps DC Constant Current Volts at Rated Amperes 25 VDC INPUT - GASOLINE ENGINE RA TED OUTPUT - WELDER Welding Ranges 50 - 125 Amps DC Welder Open Circuit Voltage 80 VDC Max.
– 2 – INST ALLA TION WELDANPOWER 125 ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. W ARNING Hazards of Electric Shock, Engine Exhaust & Moving Parts ENGINE EXHAUST can kill.
INST ALLA TION – 3 – WELDANPOWER 125 An incorrect additional arrester may lead to damage to the engine or adversely affect performance. ------------------------------------------------------------.
– 4 – INST ALLA TION WELDANPOWER 125 FIGURE A.1 and A.1a - WELDANPOWER 125 OUTPUT CONNECTIONS WELDANPOWER 125 ELECTRODE SELECTION GUIDE 75 100 125 50 AMPS AMPS AMPS AMPS WARNING MAX 6 5 3 1 2 4 + .
INST ALLA TION – 5 – WELDANPOWER 125 MACHINE GROUNDING Because this portable engine driven welder or generator creates its own power, it is not necessary to connect its frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.
– 6 – INST ALLA TION WELDANPOWER 125 PLUGS AND HAND HELD EQUIPMENT For further protection against electric shock, any electrical equipment connected to the generator receptacles must use a three-blade, grounded type plug or an Underwriter’s Laboratories (UL) approved double insulated tool with a two blade plug.
INST ALLA TION – 7 – WELDANPOWER 125 CAUTION Certain Electrical devices cannot be powered by the Weldanpower 125. See Table A.2 TABLE A.2 ELECTRICAL DEVICE USE WITH THE WELDANPOWER 125 Type Resist.
NOTES – 8 – WELDANPOWER 125.
OPERA TION – 9 – WELDANPOWER 125 ELECTRIC SHOCK can kill. • Do not touch electrically live parts or electrode with skin or wet clothing. • Insulate yourself from work and ground. • Always wear dry insulating gloves. FUMES AND GASES can be dangerous.
– 10 – OPERA TION WELDANPOWER 125 GRAPHIC SYMBOLS USED ON THIS EQUIPMENT OR IN THIS MANUAL W ARNING / CAUTION CHOKE OIL FUEL AIR CLEANER CIRCUIT BREAKER GROUND (AUXILIAR Y POWER) WORK CLAMP ELECTRODE WELDING ARC F AST For Codes 10158, 10160 only .
OPERA TION – 11 – WELDANPOWER 125 PRODUCT DESCRIPTION The Weldanpower 125 is designed for commercial use welder / generator applications. As a welder it provides 125 amps of DC constant current for welding with DC stick electrodes. A single dial lets you select a full range of welding output from 50 to 125 amps.
– 12 – OPERA TION WELDANPOWER 125 CONTROLS AND SETTINGS All welder/generator controls are located on the Output Control Panel. Gasoline engine controls are mounted on the engine. See Figure B.1, B.1a and the figures in the engine operation section.
– 13 – WELDANPOWER 125 ENGINE OPERA TION Engine Control Function/Operation Rocker “ Run/Stop ” Switch (For Codes 10158, 10160 Only) The two position “Run/Stop” switch is marked “I” and “O” on the red rocker and is located on the rear of the engine.
– 14 – OPERA TION WELDANPOWER 125 Break-in Period It is normal for any engine to use larger quantities of oil until break-in is accomplished. Check the oil level twice a day during the break-in period (about 50 running hours). Change the oil after the first 5 hours of operation.
OPERA TION – 15 – WELDANPOWER 125 2. Select the appropriate electrode. See Table B.2 or the ELECTRODE SELECTION GUIDE on the machine Output Control Panel. 3. Attach the work clamp securely to the work you are welding. 4. Insert the electrode into the electrode holder.
– 16 – OPERA TION WELDANPOWER 125 TABLE B.2 ELECTRODE SELECTION GUIDE CURRENT RANGE (AMPS) AWS ELECTRODE CLASSIFICATION ELECTRODE TYPE POLARITY 3/32 SIZE 1/8 SIZE 5/32 SIZE E6010 FLEETWELD® 5P DC.
OPERA TION – 17 – WELDANPOWER 125 TABLE B.3 AUXILIARY POWER APPLICATIONS Suggested Power Applications Running Watts *Start-up Watts (Continuous) (Surge) *Air Compressor - 1 HP 2,000 4,000 - 8,000 .
– 18 – ACCESSORIES WELDANPOWER 125 OPTIONS/ACCESSORIES The following options/accessories are available for your WELDANPOWER 125 from your local Lincoln Distributor: Accessory Kit (K875) – Includes the following: • Twenty feet (6.1 meters) of #6 AWG electrode cable with lug.
MAINTENANCE – 19 – WELDANPOWER 125 SAFETY PRECAUTIONS • Have qualified personnel do all maintenance and troubleshooting work. • Turn the engine off before working inside the machine. • Remove guards only when necessary to perform maintenance and replace them when the maintenance requiring their removal is complete.
– 20 – MAINTENANCE WELDANPOWER 125 To service the pre-cleaner : Remove the wing nuts and cover for Codes 10158, 10160) Remove the cover for (Codes 11183, 11406). Carefully remove the foam pre-cleaner from the filter element. 1. Wash in liquid detergent and water.
How T o Use T roubleshooting Guide This Troubleshooting Guide is designed to be used by the machine Owner/Operator. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty.
– 22 – TROUBLESHOOTING WELDANPOWER 125 Observe Safety Guidelines detailed in the beginning of this manual. T roubleshooting Guide If for any reason you do not understand the test procedures or are.
– 23 – TROUBLESHOOTING WELDANPOWER 125 Observe Safety Guidelines detailed in the beginning of this manual. T roubleshooting Guide If for any reason you do not understand the test procedures or are.
– 24 – TROUBLESHOOTING WELDANPOWER 125 Observe Safety Guidelines detailed in the beginning of this manual. T roubleshooting Guide If for any reason you do not understand the test procedures or are.
WIRING DIAGRAM – 25 – D1 C1 ROTOR (+) (-) (+) (-) (+) (-) D2 (+) (-) R1 STATOR 115 VOLT CHOKE ENGINE W IRING MAG OUTPUT STUDS L1 202 230 VOLT 203 203 204 CCW 1 HOUR METER IDLE SW ITCH HI AUTO 209 CB1 CB2 + 200A 200 201A 201 201B RED RUN/STOP SWITCH Y 3.
– 26 – WIRING DIAGRAM ) NOTE: This diagram is for reference only. It may not be accurate for all machines covered by this manual. The specific diagram for a particular code is pasted inside the machine on one of the enclosure panels. If the diagram is illegible, write to the Service Department for a replacement.
– 27 – WELDANPOWER 125 WIRING DIAGRAM D1 C1 (+) (-) (+) (-) (+) (-) STATOR 120 VOLT CHOKE A.01 L1 202 240 VOLT HOUR METER CB1 CB2 + 201A 201 WH ITE T ERMINALS 600 FD 201B NOTE: ALL CASE FRONT COMPONENTS SHOWN VIEW ED FROM REAR.
– 28 – 20.00 508 REF. 21.13 537 REF. R 7.92 201 REF. 13.62 346 REF. 30.00 762 REF. LINCOLN LINCOLN ELECTRIC ELECTRIC M17614 2-17-95 DIMENSION PRINT WELDANPOWER 125.
NOTES WELDANPOWER 125 – 29 –.
– 30 – NOTES WELDANPOWER 125.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
– 32 – W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE P ARA ESTE EQUIPAMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
デバイスLincoln Electric IM530-Cの購入後に(又は購入する前であっても)重要なポイントは、説明書をよく読むことです。その単純な理由はいくつかあります:
Lincoln Electric IM530-Cをまだ購入していないなら、この製品の基本情報を理解する良い機会です。まずは上にある説明書の最初のページをご覧ください。そこにはLincoln Electric IM530-Cの技術情報の概要が記載されているはずです。デバイスがあなたのニーズを満たすかどうかは、ここで確認しましょう。Lincoln Electric IM530-Cの取扱説明書の次のページをよく読むことにより、製品の全機能やその取り扱いに関する情報を知ることができます。Lincoln Electric IM530-Cで得られた情報は、きっとあなたの購入の決断を手助けしてくれることでしょう。
Lincoln Electric IM530-Cを既にお持ちだが、まだ読んでいない場合は、上記の理由によりそれを行うべきです。そうすることにより機能を適切に使用しているか、又はLincoln Electric IM530-Cの不適切な取り扱いによりその寿命を短くする危険を犯していないかどうかを知ることができます。
ですが、ユーザガイドが果たす重要な役割の一つは、Lincoln Electric IM530-Cに関する問題の解決を支援することです。そこにはほとんどの場合、トラブルシューティング、すなわちLincoln Electric IM530-Cデバイスで最もよく起こりうる故障・不良とそれらの対処法についてのアドバイスを見つけることができるはずです。たとえ問題を解決できなかった場合でも、説明書にはカスタマー・サービスセンター又は最寄りのサービスセンターへの問い合わせ先等、次の対処法についての指示があるはずです。